多普勒超声门控胎儿心脏电影MRI在复杂先天性心脏病中的应用
这项前瞻性研究纳入23例复杂先天性心脏病胎儿,在同一天行胎儿超声心动图和多普勒超声门控胎儿心脏电影MRI,以出生后检查结果为参考标准。MRI与超声心动图检测心血管异常特征的敏感度和特异度无显著差异,MRI在1例中纠正了诊断。
要点
- 多普勒超声门控胎儿心脏电影MRI在23例中全部完成,图像质量中位评分为3分(IQR 2.5-4)。
- MRI与超声心动图检测异常心血管特征的敏感度分别为91.8%和93.6%,特异度均为99.9%。
- MRI在1例中独立做出正确诊断:内脏反位合并先天性矫正型大动脉转位。
核心结论
- 多普勒超声门控胎儿电影心脏MRI诊断复杂胎儿先天性心脏病的性能与胎儿超声心动图相当。
研究设计与样本
- 前瞻性研究,2021年5月至2022年3月纳入23例孕妇(平均年龄32岁±5,平均孕周36周±1),同日行胎儿超声心动图和多普勒超声门控胎儿心脏MRI,MRI采用平衡稳态自由进动电影序列采集轴位及可选矢状位和/或冠状位图像,以出生后检查结果为参考标准。
关键影像表现/征象
- MRI图像质量采用四点Likert量表评估,中位总体图像质量为3分(IQR 2.5-4)。
- MRI在21/23例(91%)中正确评估了基础先天性心脏病。
- 1例仅通过MRI做出正确诊断:内脏反位合并先天性矫正型大动脉转位。
诊断标准与关键数值
- MRI检测异常心血管特征的敏感度为91.8%(95% CI: 85.7, 95.1),超声心动图为93.6%(95% CI: 88.8, 96.2),P = .53。
- MRI检测异常心血管特征的特异度为99.9%(95% CI: 99.2, 100),超声心动图为99.9%(95% CI: 99.5, 100),P > .99。
- 图像质量采用四点Likert量表:1=不可诊断,4=图像质量好。
临床应用与阅片要点
- 多普勒超声门控胎儿心脏电影MRI可作为胎儿超声心动图的补充手段用于复杂先天性心脏病的产前评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To apply Doppler US (DUS)-gated fetal cardiac cine MRI in clinical routine and investigate diagnostic performance in complex congenital heart disease (CHD) compared with that of fetal echocardiography.
MATERIALS AND METHODS: In this prospective study (May 2021 to March 2022), women with fetuses with CHD underwent fetal echocardiography and DUS-gated fetal cardiac MRI on the same day. For MRI, balanced steady-state free precession cine images were acquired in the axial and optional sagittal and/or coronal orientations. Overall image quality was assessed on a four-point Likert scale (from 1 = nondiagnostic to 4 = good image quality). The presence of abnormalities in 20 fetal cardiovascular features was independently assessed by using both modalities. The reference standard was postnatal examination results. Differences in sensitivities and specificities were determined by using a random-effects model.
RESULTS: The study included 23 participants (mean age, 32 years ± 5 [SD]; mean gestational age, 36 weeks ± 1). Fetal cardiac MRI was completed in all participants. The median overall image quality of DUS-gated cine images was 3 (IQR, 2.5-4). In 21 of 23 participants (91%), underlying CHD was correctly assessed by using fetal cardiac MRI. In one case, the correct diagnosis was made by using MRI only (situs inversus and congenitally corrected transposition of the great arteries). Sensitivities (91.8% [95% CI: 85.7, 95.1] vs 93.6% [95% CI: 88.8, 96.2]; P = .53) and specificities (99.9% [95% CI: 99.2, 100] vs 99.9% [95% CI: 99.5, 100]; P > .99) for the detection of abnormal cardiovascular features were comparable between MRI and echocardiography, respectively.
CONCLUSION: Using DUS-gated fetal cine cardiac MRI resulted in performance comparable with that of using fetal echocardiography for diagnosing complex fetal CHD.Keywords: Pediatrics, MR-Fetal (Fetal MRI), Cardiac, Heart, Congenital, Fetal Imaging, Cardiac MRI, Prenatal, Congenital Heart DiseaseClinical trial registration no. NCT05066399 Supplemental material is available for this article. © RSNA, 2023See also the commentary by Biko and Fogel in this issue.
引用
- Vollbrecht, Hart, Zhang, et al. Fetal Cardiac Cine MRI with Doppler US Gating in Complex Congenital Heart Disease. Radiol Cardiothorac Imaging. 2023. PMID: 36860838. doi:10.1148/ryct.220129
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。