文献速递骨肌MR

基于肩关节MRI的影像组学诊断及严重程度分期评估手术治疗的冈上肌腱撕裂

Shoulder MRI-based radiomics for diagnosis and severity staging assessment of surgically treated supraspinatus tendon tears.
PubMed 文献 · Eur Radiol · 2023-03-01

本研究开发并验证了基于肩关节MRI的影像组学模型,以关节镜为参考标准,用于评估冈上肌腱撕裂。共纳入432例患者(训练集332例,外部验证集100例),从脂肪抑制T2加权冠状面图像提取影像组学特征。模型在区分无撕裂与撕裂方面表现优异(AUC 0.98),在区分全层与部分层撕裂方面表现中等(AUC 0.79)。

要点

  • 影像组学模型可高精度排除冈上肌腱撕裂,准确率93.6%,敏感度91.6%,特异度95.2%。
  • 模型区分全层与部分层撕裂性能中等,准确率76.4%,敏感度79.2%,特异度74.3%。
  • 基于脂肪抑制T2加权冠状面图像提取特征,使用逻辑回归建模,外部验证集验证。

局限性

  • 原文未明确提及研究局限性;但外部验证集样本量较小(100例),可能影响泛化性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To develop and validate MRI-based radiomics models capable of evaluating supraspinatus tendon tears within the shoulder joints by using arthroscopy as the reference standard.

METHODS: A total of 432 patients (332 in the training set and 100 in the external validation set) with intact supraspinatus tendon (n = 202) and supraspinatus tendon tear (n = 230, 130 full-thickness tears and 100 partial-thickness tears) were enrolled. Radiomics features were extracted from fat-saturated T2-weighted coronal images. Two radiomics signature models for detecting supraspinatus tendon abnormalities (tear or not), and stage lesion severity (full- or partial-thickness tear) and radiomics scores (Rad-score), were constructed and calculated using multivariate logistic regression analysis. The diagnostic performance of the two models was validated using ROC curves on the training and validation datasets.

RESULTS: For the radiomics model of no tears or tears, thirteen features from MR images were used to build the radiomics signature with an AUC value of 0.98 in the training set, 0.97 in the internal validation set, and 0.98 in the external validation set. For the radiomics model of full- or partial-thickness tears, thirteen features from MR images were used to build the radiomics signature with an AUC value of 0.79 in the training set, 0.69 in the internal validation set, and 0.77 in the external validation set.

CONCLUSION: The proposed radiomics models in this study can accurately rule out supraspinatus tendon tears and are capable of assessing the severity staging of tears with moderate accuracy based on shoulder MR images.

KEY POINTS: • The radiomics model of no tears or tears achieved a high overall accuracy of 93.6%, sensitivity of 91.6%, and specificity of 95.2% for supraspinatus tendon tears. • The radiomics model of full- or partial-thickness tears displayed moderate performance with an accuracy of 76.4%, a sensitivity of 79.2%, and a specificity of 74.3% for supraspinatus tendon tears severity staging.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zhan, Liu, Dong, et al. Shoulder MRI-based radiomics for diagnosis and severity staging assessment of surgically treated supraspinatus tendon tears. Eur Radiol. 2023. PMID: 36856840. doi:10.1007/s00330-023-09523-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。