文献速递妇产影像MR

鉴别正常胎盘与胎儿生长受限并发症胎盘:T2*成像是否比常规扩散加权成像更准确?

Differentiating between normal and fetal growth restriction-complicated placentas: is T2∗ imaging imaging more accurate than conventional diffusion-weighted imaging?
PubMed 文献 · Clin Radiol · 2023-02-16

这项前瞻性研究纳入28例对照胎盘和30例胎儿生长受限(FGR)胎盘,在3T磁共振上比较T2*成像与表观扩散系数(ADC)的鉴别效能。FGR胎盘的T2*成像Z评分与ADC均显著降低;T2*成像Z评分的曲线下面积(AUC)为0.917,ADC为0.788,T2*成像鉴别FGR胎盘的效能显著优于ADC(Z=2.043,p=0.041)。作者结论为胎盘T2*成像在区分正常与FGR胎盘方面比ADC更可靠。

要点

  • FGR胎盘ADC与T2*成像Z评分均显著低于正常胎盘(p<0.001)。
  • T2*成像Z评分鉴别FGR胎盘的AUC为0.917,高于ADC的0.788。
  • T2*成像鉴别FGR胎盘的效能显著优于ADC(Z=2.043,p=0.041)。

核心结论

  • 胎盘T2*成像在区分正常与FGR胎盘方面比ADC更可靠。

研究设计与样本

  • 前瞻性研究,纳入28例对照胎盘和30例FGR胎盘,使用3T磁共振系统,对所有孕妇行16个不同回波时间的梯度回波磁共振成像及b值为0和800 s/mm²的扩散加权成像。

关键影像表现/征象

  • FGR胎盘ADC为(1.42±0.28)×10⁻³ mm²/s,低于对照胎盘的(1.69±0.19)×10⁻³ mm²/s(p<0.001)。
  • FGR胎盘T2*成像Z评分为-2.441±1.48,低于对照胎盘的-0.004±0.95(p<0.001)。

诊断标准与关键数值

  • T2*成像Z评分鉴别FGR胎盘的AUC为0.917(95%CI=0.842-0.991)。
  • ADC鉴别FGR胎盘的AUC为0.788(95%CI=0.655-0.887)。
  • T2*成像与ADC鉴别FGR胎盘的效能比较:Z=2.043,p=0.041。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare the performance of T2∗ imaging and apparent diffusion coefficient (ADC) in differentiating normal placentas from those complicated by fetal growth restriction (FGR).

MATERIALS AND METHODS: This prospective study included 28 control and 30 FGR placentas. Gradient-echo magnetic resonance imaging (MRI) at 16 different echo times and diffusion-weighted imaging (b-value of 0 and 800 s/mm2) were performed on all pregnant women using a 3 T MRI system.

RESULTS: Both T2∗ imaging Z-score and ADC were significantly lower in the FGR placentas (ADC, (1.69 ± 0.19) × 10-3 versus (1.42 ± 0.28) × 10-3 mm2/s, p<0.001; T2∗ imaging Z-score, -0.004 ± 0.95 versus -2.441 ± 1.48, p<0.001). The area under the curve for T2∗ imaging Z-score and ADC was 0.917 (95% confidence interval [CI] = 0.842-0.991) and 0.788 (95% CI = 0.655-0.887), respectively. The performance of T2∗ imaging in differentiating FGR placentas was significantly better than that of ADC (Z = 2.043, p=0.041).

CONCLUSION: Placental T2∗ imaging was found to be more reliable than ADC in differentiating between normal and FGR placentas.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Wen, Chang, He, et al. Differentiating between normal and fetal growth restriction-complicated placentas: is T2∗ imaging imaging more accurate than conventional diffusion-weighted imaging? Clin Radiol. 2023. PMID: 36858925. doi:10.1016/j.crad.2023.01.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。