深度学习在致密乳腺等密度隐匿性肿块检测中的应用
本研究回顾性分析深度学习在致密乳腺等密度/隐匿性肿块检测中的性能,通过融入传统乳腺影像学教学原则构建模型,并在诊断性及筛查性乳腺X线数据集上验证。结果显示,在0.2假阳性/图像下,致密乳腺患者敏感度从67.9%提升至73.8%,等密度/隐匿性癌敏感度从74.6%提升至85.3%,外部验证筛查数据集敏感度从84.9%提升至88.7%。
要点
- 深度学习模型结合传统影像学特征可提高致密乳腺中癌的检出敏感度。
- 在0.2假阳性/图像条件下,等密度/隐匿性癌的敏感度提升至85.3%。
- 外部验证显示模型在筛查性乳腺X线分布中敏感度达88.7%。
局限性
- 回顾性研究设计。
- 单机构来源,外部验证仅来自一个不同中心。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To analyze the performance of deep learning in isodense/obscure masses in dense breasts. To build and validate a deep learning (DL) model using core radiology principles and analyze its performance in isodense/obscure masses. To show performance on screening mammography as well as diagnostic mammography distribution.
METHODS: This was a retrospective, single-institution, multi-centre study with external validation. For model building, we took a 3-pronged approach. First, we explicitly taught the network to learn features other than density differences: such as spiculations and architectural distortion. Second, we used the opposite breast to enable the detection of asymmetries. Third, we systematically enhanced each image by piece-wise-linear transformation. We tested the network on a diagnostic mammography dataset (2569 images with 243 cancers, January to June 2018) and a screening mammography dataset (2146 images with 59 cancers, patient recruitment from January to April 2021) from a different centre (external validation).
RESULTS: When trained with our proposed technique (and compared with baseline network), sensitivity for malignancy increased from 82.7 to 84.7% at 0.2 False positives per image (FPI) in the diagnostic mammography dataset, 67.9 to 73.8% in the subset of patients with dense breasts, 74.6 to 85.3 in the subset of patients with isodense/obscure cancers and 84.9 to 88.7 in an external validation test set with a screening mammography distribution. We showed that our sensitivity exceeded currently reported values (0.90 at 0.2 FPI) on a public benchmark dataset (INBreast).
CONCLUSION: Modelling traditional mammographic teaching into a DL framework can help improve cancer detection accuracy in dense breasts.
CLINICAL RELEVANCE STATEMENT: Incorporating medical knowledge into neural network design can help us overcome some limitations associated with specific modalities. In this paper, we show how one such deep neural network can help improve performance on mammographically dense breasts.
KEY POINTS: • Although state-of-the-art deep learning networks achieve good results in cancer detection in mammography in general, isodense, obscure masses and mammographically dense breasts posed a challenge to deep learning networks. • Collaborative network design and incorporation of traditional radiology teaching into the deep learning approach helped mitigate the problem. • The accuracy of deep learning networks may be translatable to different patient distributions. We showed the results of our network on screening as well as diagnostic mammography datasets.
引用
- Rangarajan, Aggarwal, Gupta, et al. Deep learning for detection of iso-dense, obscure masses in mammographically dense breasts. Eur Radiol. 2023. PMID: 37209125. doi:10.1007/s00330-023-09717-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。