文献速递心血管MR

深度学习约束压缩感知加速非增强全心bSSFP冠状动脉MR血管成像的可行性

Feasibility of accelerated non-contrast-enhanced whole-heart bSSFP coronary MR angiography by deep learning-constrained compressed sensing.
PubMed 文献 · Eur Radiol · 2023-05-20

CSAI采集时间显著短于SENSE(10.2±3.2 min vs 13.0±4.1 min),且图像质量评分、血池均匀性、SNR和CNR均最高(均p<0.001)。CSAI诊断显著狭窄(≥50%直径狭窄)的每患者敏感度87.5%、特异度91.7%、准确率90.0%。

要点

  • CSAI将采集时间较SENSE缩短22%,同时提供更优的诊断图像质量。
  • CSAI在CS算法中以CNN替代小波变换作为稀疏变换,降低噪声并提高冠状动脉MR图像质量。
  • CSAI对显著冠状动脉狭窄(≥50%直径狭窄)的每患者敏感度87.5%、特异度91.7%。

关键影像表现/征象

  • CSAI组图像质量评分、血池均匀性、平均SNR值和平均CNR值均最高(均p<0.001)。
  • CSAI和CS组采集时间均显著短于SENSE组(10.2±3.2 min vs 10.9±2.9 min vs 13.0±4.1 min,p<0.001)。

诊断标准与关键数值

  • 以CCTA为参考,CSAI冠状动脉MRA诊断显著狭窄(≥50%直径狭窄)的每患者敏感度87.5%(7/8)、特异度91.7%(11/12)、准确率90.0%(18/20)。
  • 每血管敏感度81.8%(9/11)、特异度93.9%(46/49)、准确率91.7%(55/60)。
  • 每节段敏感度84.6%(11/13)、特异度98.0%(244/249)、准确率97.3%(255/262)。

临床应用与阅片要点

  • CSAI可在约10分钟采集时间内提供高质量非增强冠状动脉MRA图像,适合疑似CAD患者的无辐射筛查。
  • 判读时关注CSAI图像噪声降低和血池均匀性提升,有助于提高冠状动脉管腔评估可信度。
  • 以CCTA为参考时,CSAI对显著狭窄的每患者敏感度87.5%、特异度91.7%,需注意假阳性和假阴性可能。

局限性

  • 患者样本量较小(20例),诊断性能评估的准确性有限。
  • 仅疑似CAD患者行CSAI,未在患者中头对头比较CSAI与CS或SENSE。
  • 参考标准为CCTA而非有创冠状动脉造影。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To examine a compressed sensing artificial intelligence (CSAI) framework to accelerate image acquisition in non-contrast-enhanced whole-heart bSSFP coronary magnetic resonance (MR) angiography.

METHODS: Thirty healthy volunteers and 20 patients with suspected coronary artery disease (CAD) scheduled for coronary computed tomography angiography (CCTA) were enrolled. Non-contrast-enhanced coronary MR angiography was performed with CSAI, compressed sensing (CS), and sensitivity encoding (SENSE) methods in healthy participants and with CSAI in patients. Acquisition time, subjective image quality score, and objective image quality measurement (blood pool homogeneity, signal-to-noise ratio [SNR], and contrast-to-noise ratio [CNR]) were compared among the three protocols. The diagnostic performance of CASI coronary MR angiography for predicting significant stenosis (≥ 50% diameter stenosis) on CCTA was evaluated. The Friedman test was performed to compare the three protocols.

RESULTS: Acquisition time was significantly shorter in the CSAI and CS groups than in the SENSE group (10.2 ± 3.2 min vs. 10.9 ± 2.9 min vs. 13.0 ± 4.1 min, p < 0.001). However, the CSAI approach had the highest image quality scores, blood pool homogeneity, mean SNR value, and mean CNR value (all p < 0.001) compared with the CS and SENSE approaches. The sensitivity, specificity, and accuracy of CSAI coronary MR angiography per patient were 87.5% (7/8), 91.7% (11/12), and 90.0% (18/20); those per vessel were 81.8% (9/11), 93.9% (46/49), and 91.7% (55/60); and those per segment were 84.6% (11/13), 98.0% (244/249), and 97.3% (255/262), respectively.

CONCLUSIONS: CSAI yielded superior image quality within a clinically feasible acquisition time in healthy participants and patients with suspected CAD.

CLINICAL RELEVANCE STATEMENT: The non-invasive and radiation-free CSAI framework could be a promising tool for rapid screening and comprehensive examination of the coronary vasculature in patients with suspected CAD.

KEY POINTS: • This prospective study showed that CSAI enables a reduction in acquisition time by 22% with superior diagnostic image quality compared with the SENSE protocol. • CSAI replaces the wavelet transform with a CNN as a sparsifying transform in the CS algorithm, achieving high coronary MR image quality with reduced noise. • CSAI achieved per-patient sensitivity of 87.5% (7/8) and specificity of 91.7% (11/12) respectively for detecting significant coronary stenosis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Wu, Tang, Li, et al. Feasibility of accelerated non-contrast-enhanced whole-heart bSSFP coronary MR angiography by deep learning-constrained compressed sensing. Eur Radiol. 2023. PMID: 37209126. doi:10.1007/s00330-023-09740-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。