文献速递头颈神经MR

DWI联合常规MRI鉴别鼻腔鼻窦恶性黑色素瘤与鳞状细胞癌

Differentiating sinonasal malignant melanoma from squamous cell carcinoma using DWI combined with conventional MRI.
PubMed 文献 · Neuroradiology · 2023-05-20

回顾性分析37例SNMM和44例SNSCC的常规MRI特征及ADC值,发现SNMM多位于鼻腔、边界清楚、T1呈分隔模式或异质高信号,ADC值显著低于SNSCC;联合位置、T1信号、T2网状/线状高信号及MS ADC阈值0.87×10-3mm2/s,敏感度97.3%、特异度68.2%、AUC 0.89。

要点

  • SNMM多位于鼻腔、边界清楚、T1分隔模式或异质高信号,ADC值更低。
  • SNSCC多位于鼻窦、T1等信号、边界不清、T2网状/线状高信号。
  • 联合常规MRI特征与MS ADC阈值0.87×10-3mm2/s可高效鉴别两者。

关键影像表现/征象

  • SNMM更常位于鼻腔,边界清楚,T1呈分隔模式(T1-SP)和异质性T1高信号。
  • SNSCC更常位于鼻旁窦,T1呈均匀等信号,边界不清,T2呈网状或线状高信号,并常累及翼腭窝或眼眶(均p<0.05)。
  • SNMM的平均ADC(MS ADC 0.85×10-3mm2/s;SSS ADC 0.69×10-3mm2/s)显著低于SNSCC(MS ADC 1.05×10-3mm2/s;SSS ADC 0.82×10-3mm2/s)(p<0.05)。

诊断标准与关键数值

  • 联合位置、T1信号强度、T2网状或线状高信号及MS ADC截断值0.87×10-3mm2/s,鉴别SNMM与SNSCC的敏感度97.3%、特异度68.2%、AUC 0.89。

临床应用与阅片要点

  • 阅片时注意肿瘤位置(鼻腔 vs 鼻旁窦)、边界、T1信号模式及T2网状/线状高信号。
  • 测量ADC时采用最大层面(MS)ROI,以0.87×10-3mm2/s为阈值辅助鉴别。
  • SNMM的ADC值更低,但特异度中等,需结合常规MRI特征综合判断。

局限性

  • 回顾性研究,样本量有限(37例SNMM和44例SNSCC),可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aimed to investigate the feasibility of diffusion-weighted imaging (DWI) in combination with conventional MRI features to differentiate sinonasal malignant melanoma (SNMM) from sinonasal squamous cell carcinoma (SNSCC).

METHODS: A total of 37 patients with SNMM and 44 patients with SNSCC were retrospectively reviewed. Conventional MRI features and apparent diffusion coefficients (ADCs) were evaluated independently by two experienced head and neck radiologists. ADCs were obtained from two different regions of interest (ROIs) including maximum slice (MS) and small solid sample (SSS). Multivariate logistic regression analysis was performed to identify significant MR imaging features in discriminating between SNMM and SNSCC. Receiver operating characteristic (ROC) curves were used to assess the diagnostic performance.

RESULTS: SNMMs were more frequently located in the nasal cavity, with well-defined border, T1 Septate Pattern (T1-SP) and heterogeneous T1 hyperintensity, whereas SNSCCs were more frequently located in the paranasal sinus, with homogenous T1 isointensity, ill-defined border, reticular or linear T2 hyperintensity, and pterygopalatine fossa or orbital involvement (all p < 0.05). The mean ADCs of SNMM (MS ADC, 0.85 × 10-3mm2/s; SSS ADC, 0.69 × 10-3mm2/s) were significantly lower than those of SNSCC (MS ADC, 1.05 × 10-3mm2/s; SSS ADC, 0.82 × 10-3mm2/s) (p < 0.05). With a combination of location, T1 signal intensity, reticular or linear T2 hyperintensity, and a cut-off MS ADC of 0.87 × 10-3mm2/s, the sensitivity, specificity, and AUC were 97.3%, 68.2%, and 0.89, respectively.

CONCLUSION: DWI combined with conventional MRI can effectively improve the diagnostic performance in differentiating SNMM from SNSCC.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Liu, Wang, Su, et al. Differentiating sinonasal malignant melanoma from squamous cell carcinoma using DWI combined with conventional MRI. Neuroradiology. 2023. PMID: 37208530. doi:10.1007/s00234-023-03164-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。