经皮移除延伸至右心房并致肺栓塞的骨水泥一例
本文报告一例72岁女性在经皮椎体成形术1个月后出现胸痛、呼吸困难、低血压和心房颤动,超声心动图见右心房内自由活动的线状高回声结构,估测肺动脉收缩压45 mmHg,CT血管造影显示骨水泥从L2椎体经下腔静脉延伸至右心房并伴远端肺动脉分支骨水泥栓塞,采用三叶圈套器联合球囊辅助成功经皮移除心内骨水泥。
要点
- 椎体成形术后心内骨水泥栓塞是罕见但可能危及生命的并发症。
- 经胸超声心动图和CT血管造影有助于诊断心内及肺血管骨水泥栓塞。
- 对选定患者,经皮移除心内骨水泥可考虑作为开放手术的安全有效替代。
核心结论
- 心内骨水泥栓塞是椎体成形术后罕见且可能危及生命的并发症,经皮移除在选定患者中可考虑为开放手术的安全有效替代。
研究设计与样本
- 病例报告:一例72岁女性在经皮椎体成形术后1个月出现胸痛、呼吸困难、低血压和心房颤动。
主要发现
- 经胸超声心动图显示右心房内自由活动的线状高回声结构,估测肺动脉收缩压为45 mmHg。
- CT血管造影显示骨水泥从L2椎体经下腔静脉延伸至右心房,并见远端肺动脉分支骨水泥栓塞。
- 采用三叶圈套器联合球囊辅助成功经皮移除心内骨水泥。
临床怎么用
- 椎体成形术后患者出现胸痛、呼吸困难、低血压或心房颤动时,应警惕心内骨水泥栓塞可能。
- 经胸超声心动图和CT血管造影可用于评估心内及肺血管骨水泥栓塞。
- 对选定患者,可考虑经皮移除心内骨水泥作为开放手术的替代方案。
局限性
- 本文为单例病例报告,结论的普遍适用性有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
ABSTRACT Percutaneous vertebroplasty is a minimally invasive procedure injecting polymethylmethacrylate cement to increase vertebral stability in vertebral compression fractures. We present a patient who presented with recurrent pulmonary embolism due to intracardiac cement embolism after vertebroplasty with successful percutaneous cement removal. A 72-year-old woman presented with chest pain, dyspnea, hypotension, and atrial fibrillation 1 month after vertebroplasty. Transthoracic echocardiography revealed a freely mobile hyperechoic linear structure in the right atrium; estimated pulmonary artery systolic pressure was 45 mmHg. Computed tomography angiography demonstrated a cement cast extending from L2 vertebra through the inferior vena cava into the right atrium and cement emboli in distal pulmonary arterial branches. Intracardiac cement was successfully removed using a three-lobed snare with balloon assist. Intracardiac cement embolism is a rare, potentially life-threatening complication following vertebroplasty. Percutaneous removal may be considered a safe and effective alternative to open surgery in selected patients.
引用
- Catheterization and Cardiovascular Interventions:Percutaneous Removal of Cement Extending to the Right Atrium and Causing Pulmonary Embolism After Percutaneous Vertebroplasty: A Case Report
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。