基于Murray定律的2D-μQFR与3D-μQFR及vFFR诊断准确性比较:VERMONT研究
本研究为前瞻性VERMONT试验的子研究,回顾性分析209例患者225个中间病变的造影图像,以导丝FFR≤0.80为参考标准,评估2D-μQFR的诊断准确性与时间效率。结果显示2D-μQFR的AUC为0.95,敏感度93%、特异度92%;诊断性能与3D-μQFR相当,特异度优于vFFR,且分析时间较导丝FFR快15.1分钟。
要点
- 2D-μQFR诊断FFR≤0.80的AUC达0.95,敏感度93%、特异度92%。
- 2D-μQFR与3D-μQFR诊断性能相当,特异度优于vFFR。
- 2D-μQFR分析较导丝FFR快15.1分钟,观察者间一致性r=0.94。
核心结论
- 单投影2D-μQFR提供准确、快速、可重复的生理学评估,性能与3D-μQFR相当,特异度优于vFFR。
- 研究支持2D-μQFR作为常规临床实践中 invasve FFR 的实用无导丝替代方案。
研究设计与样本
- 前瞻性VERMONT试验的子研究,回顾性分析前瞻性获取的造影图像,以导丝FFR≤0.80为参考标准。
- 共纳入209例患者225个中间病变,其中205个病变被分析。
主要发现
- 2D-μQFR诊断FFR≤0.80的AUC为0.95(95%CI 0.93–0.98),敏感度93%、特异度92%、PPV 88%、NPV 95%。
- 2D-μQFR观察者间一致性极佳(r=0.94,p<0.001),分析时间较导丝FFR快15.1分钟(1.8±0.7 vs. 16.9±5.4分钟,p<0.001)。
- 3D-μQFR的AUC为0.94(95%CI 0.91–0.97),敏感度89%、特异度90%、PPV 86%、NPV 93%。
- vFFR的AUC为0.92(95%CI 0.89–0.96),敏感度90%、特异度79%、PPV 74%、NPV 93%。
- 在因图像质量限制被vFFR排除的病变中,85%可行单投影分析。
临床怎么用
- 2D-μQFR可作为无导丝FFR替代工具,用于中间病变的生理学评估,节省操作时间。
- 对于vFFR因图像质量受限的病变,可尝试单投影2D-μQFR分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
ABSTRACT Background Murray law-based quantitative flow ratio (μQFR) is an angiography-derived physiological index that utilizes a single angiographic projection with artificial intelligence-guided vessel segmentation. Aims To evaluate the diagnostic accuracy and time efficacy of 2D-μQFR against wire-based fractional flow reserve (FFR ≤ 0.80), compare its performance with 3D-μQFR and vessel-FFR (vFFR), and assess feasibility in lesions excluded from vFFR analysis. Methods This sub-study of the prospective VERMONT trial analyzed 2D- and 3D-μQFR retrospectively using prospectively acquired angiograms, with wire-based FFR as the reference standard. Results Among 209 patients with 225 intermediate lesions, 205 lesions were analyzed. 2D-μQFR demonstrated excellent diagnostic accuracy for FFR ≤ 0.80 (AUC 0.95; 95% CI 0.93–0.98), with 93% sensitivity, 92% specificity, 88% positive predictive value (PPV), and 95% negative predictive value (NPV). Inter-observer agreement was excellent (r = 0.94, p < 0.001), and 2D-μQFR analysis was 15.1 min faster than wire-based FFR (1.8 ± 0.7 vs. 16.9 ± 5.4 min, p < 0.001). Diagnostic performance was comparable to that of 3D-μQFR, which achieved an AUC of 0.94 (95% CI 0.91–0.97), with 89% sensitivity, 90% specificity, 86% PPV, and 93% NPV. It was more specific than vFFR, which achieved an AUC of 0.92 (95% CI 0.89–0.96), with 90% sensitivity, 79% specificity, 74% PPV, and 93% NPV. Single-projection analysis was feasible in 85% of lesions excluded from vFFR due to image quality limitations. Conclusion Single-projection 2D-μQFR provides accurate, rapid, and reproducible physiological assessment comparable to 3D-μQFR with superior specificity to vFFR. These findings support 2D-μQFR as a practical, wire-free alternative to invasive FFR in routine clinical practice.