指南与共识心力衰竭与心肌病

英国多学会左心室Impella支持患者急诊管理与复苏共识

UK multisociety consensus statement on the emergency management and resuscitation of patients with left-sided Impella support.
指南 / 共识 · Heart · 2026-10-09

The use of left-sided Impella microaxial flow pumps has expanded rapidly for the management of cardiogenic shock, left ventricular unloading and as a bridge to heart transplantation.…

要点

  • 循环不足早期识别指标包括平均动脉压<30 mm Hg或呼气末二氧化碳<2 kPa。
  • 启动心肺复苏前应将Impella功率降至P2。
  • 共识提供吸引、位置异常、净化系统故障和机械故障的设备排查算法。

核心结论

  • 该多学会共识是首个针对左心室Impella支持患者急诊管理与复苏的国家标准。

研究设计与样本

  • 采用系统文献综述和改良Delphi流程,以欧洲心脏病学会推荐分级框架为指导。

主要发现

  • 专家代表就复苏最初几分钟的关键优先事项和结构化行动达成一致。
  • 共识强调早期识别循环不足、及时启动多学科响应、心肺复苏前降低Impella功率及患者团队与设备团队分工。

关键数值与推荐

  • 循环不足的早期识别标准为平均动脉压<30 mm Hg或呼气末二氧化碳<2 kPa。
  • 启动心肺复苏前应将Impella功率降至P2。

临床怎么用

  • 用于结构化临床培训,通过快速、协调且符合生理的干预改善患者结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The use of left-sided Impella microaxial flow pumps has expanded rapidly for the management of cardiogenic shock, left ventricular unloading and as a bridge to heart transplantation. However, standard life support and resuscitation algorithms are not directly applicable to patients receiving this therapy due to fundamental alterations in circulatory physiology. To address this gap, eleven UK Impella centres and eight national professional societies collaborated to develop a unified national consensus statement on the emergency management of patients with left-sided Impella support. Using a systematic review of the literature and a modified Delphi process guided by the European Society of Cardiology framework for grading recommendations, expert representatives achieved agreement on key priorities and structured actions to be undertaken in the first few minutes of resuscitation. The consensus outlines early recognition of circulatory inadequacy (mean arterial pressure <30 mm Hg or end-tidal CO₂ <2 kPa), prompt activation of multidisciplinary responders, reduction of Impella power to P2 before initiating cardiopulmonary resuscitation and structured division of patient-focused and device-focused teams. Device-specific troubleshooting algorithms are presented for suction, malposition, purge-system failure and mechanical malfunction. This multisociety consensus represents the first national standard for emergency management and resuscitation of patients supported by a left-sided Impella device and is intended to inform structured clinical training and improve patient outcomes through rapid, coordinated and physiologically tailored interventions.

来源:Heart,查看原文。版权归原作者所有。

引用

  1. Akhtar, Bowles, Costanzo, et al. UK multisociety consensus statement on the emergency management and resuscitation of patients with left-sided Impella support. Heart. 2026. PMID: 41412762. doi:10.1136/heartjnl-2025-326896

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。