文献速递心律失常

低钾血症与植入式循环记录仪检测的心房颤动

Hypokalaemia and atrial fibrillation detected by implanted loop recorders.
PubMed 文献 · Eur Heart J · 2025-01-01

本研究为 LOOP 试验的事后分析,纳入 1334 名有卒中危险因素并接受植入式循环记录仪(ILR)监测的受试者,将血浆钾与每日心房颤动(AF)进行关联分析。

要点

  • 低钾血症时 AF 发生率比为 2.24(1.29-3.88)。

核心结论

  • 低血钾与逐日 AF 发生相关,尤其见于较长 AF 发作及偏离个体惯常血钾水平时。

研究设计与样本

  • LOOP 试验事后分析,纳入 1334 名有卒中危险因素并接受 ILR 监测的受试者。
  • 关联分析采用广义和线性混合效应模型,血钾与 AF 允许 1 天时间差。

主要发现

  • 低钾血症 vs 正常血钾的 AF 发生率比为 2.24(1.29-3.88)。
  • AF <60 分钟日中低钾占 5.1%,AF >240 分钟日中低钾占 19.1%。

临床怎么用

  • 对接受连续心电监测的 AF 高危人群,关注血钾水平及个体惯常值偏离可能有助于评估 AF 风险。

局限性

  • 本研究为探索性事后分析,血钾与 AF 允许 1 天时间差,关联性不能直接推断因果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Potassium levels influence cardiac electrophysiology, yet their day-to-day association with atrial fibrillation (AF) remains unclear. This study investigated the association between plasma potassium (p-potassium) and daily AF in at-risk individuals undergoing continuous electrocardiographic monitoring. METHODS: This is a post hoc analysis of the LOOP study randomizing participants with stroke risk factors to implantable loop recorder (ILR) screening for AF (n = 1501) or usual care. The ILR raw data were linked to p-potassium measurements collected in routine care allowing for 1-day time difference. Associations between p-potassium and daily AF > 60 min (main outcome) were analysed using generalized and linear mixed effect models. RESULTS: The ILR data and blood tests results were available for 1334 participants combining >1.6 million days of heart rhythm monitoring (including 50 746 days with AF) with 12 136 p-potassium measurements. P-potassium was lower on days with AF [mean difference -.21 mmol/L (-.25; -.18)]. Self-controlled case analyses comparing AF incidence during hypokalaemia (p-potassium <3.5 mmol/L) vs in normal range yielded an incidence rate ratio of 2.24 (1.29-3.88). Hypokalaemia was present in 5.1% of days with AF lasting <60 min and 19.1% with AF lasting >240 min. Each mmol/L decrease in p-potassium was associated with a five-fold increase in odds of AF [adjusted odds ratio (aOR) .20 (.15-.28)], more strongly when p-potassium deviated from the individual's usual value [aOR .15 (.10-.24); P-interaction = .001], and less in participants receiving diuretics [aOR .28 (.17-.47); P-interaction < .0001]. CONCLUSIONS: This exploratory study found that low p-potassium was associated with day-to-day AF occurrence, particularly for longer episodes and when deviating from the individual's usual level.

来源:Eur Heart J,查看原文。版权归原作者所有。