文献速递心力衰竭与心肌病

分级射频房间隔造瘘正常化左房压治疗射血分数保留心衰的单臂先导研究

Left atrial pressure normalisation by graded radiofrequency atrial septostomy in heart failure with preserved ejection fraction: a single-arm pilot study.
PubMed 文献 · Heart · 2025-10-14

31例(97%)达到手术目标,中位平均左房压从19.0 mmHg降至13.0 mmHg,随访15.5个月房间隔缺损保持通畅,NYHA分级、6分钟步行距离和生活质量均有改善。

要点

  • CURB技术在HFpEF伴左房压升高患者中可行,97%达到左房压目标。
  • 中位随访15.5个月房间隔缺损保持通畅,血流动力学和功能指标改善。
  • 需进一步对照研究评估长期结局、安全性和更广泛适用性。

核心结论

  • 在HFpEF伴平均左房压升高的患者中,CURB技术可行,并与中期血流动力学和功能指标改善相关。

研究设计与样本

  • CURB采用分级球囊扩张达到平均左房压<15 mmHg目标,随后用射频消融稳定边缘。

主要发现

  • 31例(97%)达到手术目标。
  • 中位平均左房压从19.0 mmHg(IQR 18.0, 21.0)降至13.0 mmHg(IQR 12.0, 13.3)。
  • 平均肺动脉压从26.9 mmHg(SD 3.9)降至23.5 mmHg(SD 3.7)。
  • 中位随访15.5个月(IQR 11.0, 18.0),房间隔缺损保持通畅。
  • NYHA分级中位变化-1级,6分钟步行距离增加48.5米,生活质量评分降低21.7分;8例超过1年再评估显示平均左房压持续稳定。

关键数值与推荐

  • 纳入标准:HFpEF且静息平均左房压≥18 mmHg。
  • 手术目标:平均左房压<15 mmHg。

临床怎么用

  • 对于HFpEF伴静息平均左房压≥18 mmHg的患者,CURB可作为降低左房压的可行干预选择。
  • 术后需随访房间隔缺损通畅性及血流动力学、功能指标变化。

局限性

  • 需进一步对照研究评估长期结局、安全性和更广泛适用性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In heart failure with preserved ejection fraction (HFpEF), elevated mean left atrial pressure (MLAP) is a recognised haemodynamic feature. This pilot study explored the use of a personalised approach-combined radiofrequency ablation and balloon dilation (CURB)-to establish interatrial communication in patients with elevated resting MLAP. METHODS: Between September 2020 and March 2023, a single-arm study was conducted at Fuwai Hospital (Beijing, China) in patients with HFpEF and resting MLAP ≥18 mm Hg. CURB was performed using graded balloon dilation to achieve an MLAP target of <15 mm Hg, followed by rim stabilisation with radiofrequency ablation. Clinical status, interatrial fenestration and haemodynamic parameters were assessed during follow-up. RESULTS: Thirty-two patients were included (mean age 68.4 years; 59% male). The procedural target was achieved in 31 patients (97%). Median MLAP changed from 19.0 mm Hg (IQR 18.0, 21.0) to 13.0 mm Hg (IQR 12.0, 13.3), and mean pulmonary arterial pressure from 26.9 mm Hg (SD 3.9) to 23.5 mm Hg (SD 3.7). Over a median follow-up of 15.5 months (IQR 11.0, 18.0), fenestrations remained patent. The intervention was associated with favourable change in New York Heart Association functional class (median change: -1 class), 6 min walk distance (+48.5 m) and quality of life scores (-21.7 points). Reassessment in a subset (n=8) beyond 1 year showed sustained MLAP levels. CONCLUSIONS: Among patients with HFpEF and elevated MLAP, the CURB technique was feasible and associated with mid-term changes in haemodynamics and functional measures. Further controlled studies are needed to assess long-term outcomes, safety and broader applicability. TRIAL REGISTRATION NUMBER: NCT04573166.

来源:Heart,查看原文。版权归原作者所有。

引用

  1. Yan, Li, Wan, et al. Left atrial pressure normalisation by graded radiofrequency atrial septostomy in heart failure with preserved ejection fraction: a single-arm pilot study. Heart. 2025. PMID: 40425275. doi:10.1136/heartjnl-2025-325929