深度学习心电图模型用于急诊冠状动脉血运重建风险分层
本研究开发并验证了一种卷积神经网络心电图模型,用于识别急诊就诊患者中需要冠状动脉血运重建的可能性。测试队列中模型AUROC为0.91,优于临床医生心电图判读(0.65)和传统肌钙蛋白T(0.71);外部验证中模型对血运重建AUROC为0.81、对1型心肌梗死为0.85,与高敏肌钙蛋白T性能相当,但特异性更高、敏感性更低。
要点
- 深度学习心电图模型在测试队列中AUROC达0.91,显著优于临床医生判读和传统肌钙蛋白T。
- 外部验证中模型对血运重建和1型心肌梗死的AUROC分别为0.81和0.85,与高敏肌钙蛋白T相当。
- 模型较高敏肌钙蛋白T特异性更高但敏感性更低,提示可作为现有临床评估的补充工具。
核心结论
- 深度学习心电图模型能检测血运重建需求和1型心肌梗死,性能具有竞争力,可能辅助当前临床评估。
主要发现
- 测试队列中模型AUROC为0.91(95%CI 0.91-0.91),优于临床医生心电图判读(AUROC 0.65,95%CI 0.54-0.76)和传统心脏肌钙蛋白T(AUROC 0.71)。
- 外部验证队列中,模型对血运重建的AUROC为0.81(95%CI 0.81-0.82),对1型心肌梗死的AUROC为0.85(95%CI 0.84-0.85)。
- 外部验证中临床医生判读对血运重建和1型心肌梗死的AUROC分别为0.70(95%CI 0.57-0.83)和0.74(95%CI 0.56-0.92),高敏肌钙蛋白T分别为0.85和0.87。
- 与高敏肌钙蛋白T相比,心电图模型特异性更高但敏感性更低。
临床怎么用
- 该模型可能作为急诊胸痛评估的辅助工具,帮助识别需要血运重建的高危患者,但需结合临床和高敏肌钙蛋白T综合判断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Identification of patients with acute coronary syndrome requiring coronary revascularization can be challenging due to inconclusive electrocardiogram (ECG) findings or biomarker results. A deep learning model to detect ECG patterns associated with revascularization likelihood was developed, aiming to guide further assessment and reduce diagnostic uncertainty. METHODS: A convolutional neural network model was trained on 144 691 ED visits from a US cohort (60 ± 19 years; 53% female; 0.6% revascularization), tested on a separate test cohort (n = 35 995), and benchmarked against clinician ECG interpretation and cardiac troponin T (TnT). External validation was performed for the outcomes revascularization and Type 1 myocardial infarction (MI) on 18 673 ED visits from Europe (55 ± 21 years; 49% female; 1.5% revascularization; 1% Type 1 MI). Primary performance metric was area under the receiver operating characteristic curve (AUROC). RESULTS: In the test cohort, the model achieved an AUROC of 0.91 (95% confidence interval [CI] 0.91-0.91), outperforming clinician ECG interpretation (AUROC 0.65, 95% CI 0.54-0.76) and conventional cardiac TnT (AUROC 0.71). In the external validation cohort, ECG model AUROC was 0.81 (95% CI 0.81-0.82) for revascularization, and 0.85 (95% CI 0.84-0.85) for Type 1 MI, compared with 0.70 (95% CI 0.57-0.83) and 0.74 (95% CI 0.56-0.92) for clinician interpretation, and 0.85 and 0.87 for high-sensitivity (hs)-TnT, respectively. The ECG model had higher specificity but lower sensitivity compared with high-sensitivity-troponin T. CONCLUSIONS: The model was able to detect revascularization and Type 1 MI with competitive performance, suggesting a potential role to complement current clinical assessment.
引用
- Büscher, Plagwitz, Yildirim, et al. Deep learning electrocardiogram model for risk stratification of coronary revascularization need in the emergency department. Eur Heart J. 2026. PMID: 40156923. doi:10.1093/eurheartj/ehaf254
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。