文献速递冠心病

人工智能心电图排除急性心肌梗死的多中心研究

Artificial intelligence applied to electrocardiogram to rule out acute myocardial infarction: the ROMIAE multicentre study.
PubMed 文献 · Eur Heart J · 2025-01-01

ROMIAE 多中心前瞻性队列研究在韩国 18 家医院纳入 8493 例急诊疑似 AMI 成人患者,评估 AI-ECG 诊断 AMI 及预测 30 天 MACE 的性能;AI-ECG 的 AUC 为 0.878,与 HEART 评分相当,优于 GRACE 2.0、高敏肌钙蛋白和医生评估,联合 HEART 评分可改善风险分层。

要点

  • AI-ECG 诊断 AMI 的 AUC 为 0.878,与 HEART 评分(0.877)相当。
  • AI-ECG 预测 30 天 MACE 的 AUC 为 0.866,与 HEART 评分(0.858)相当。
  • AI-ECG 联合 HEART 评分使 NRI 提高 19.6%,C-index 达 0.926。

核心结论

  • AI-ECG 对 AMI 的诊断准确性和 30 天 MACE 预测能力与现有传统风险分层方法相当或更优。

主要发现

  • 1586 例(18.6%)诊断为 AMI,AI-ECG 诊断 AMI 的 AUC 为 0.878(95% CI 0.868-0.888)。
  • AI-ECG 预测 30 天 MACE 的 AUC 为 0.866(95% CI 0.856-0.877),HEART 评分为 0.858(95% CI 0.848-0.868)。
  • AI-ECG 联合 HEART 评分的净重分类改善为 19.6%(95% CI 17.38-21.89),C-index 为 0.926(95% CI 0.919-0.933)。

关键数值与推荐

  • AI-ECG 诊断 AMI 的 AUC 与 HEART 评分(0.877;95% CI 0.869-0.886)相当,优于 GRACE 2.0 评分、高敏肌钙蛋白水平和医生 AMI 评分。

临床怎么用

  • AI-ECG 可作为急诊疑似 AMI 的辅助工具,与 HEART 评分联合使用以改善风险分层和 AMI 鉴别。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Emerging evidence supports artificial intelligence-enhanced electrocardiogram (AI-ECG) for detecting acute myocardial infarction (AMI), but real-world validation is needed. The aim of this study was to evaluate the performance of AI-ECG in detecting AMI in the emergency department (ED). METHODS: The Rule-Out acute Myocardial Infarction using Artificial intelligence Electrocardiogram analysis (ROMIAE) study is a prospective cohort study conducted in the Republic of Korea from March 2022 to October 2023, involving 18 university-level teaching hospitals. Adult patients presenting to the ED within 24 h of symptom onset concerning for AMI were assessed. Exposure included AI-ECG score, HEART score, GRACE 2.0 score, high-sensitivity troponin level, and Physician AMI score. The primary outcome was diagnosis of AMI during index admission, and the secondary outcome was 30 day major adverse cardiovascular event (MACE). RESULTS: The study population comprised 8493 adults, of whom 1586 (18.6%) were diagnosed with AMI. The area under the receiver operating characteristic curve for AI-ECG was 0.878 (95% CI, 0.868-0.888), comparable with the HEART score (0.877; 95% CI, 0.869-0.886) and superior to the GRACE 2.0 score, high-sensitivity troponin level, and Physician AMI score. For predicting 30 day MACE, AI-ECG (area under the receiver operating characteristic, 0.866; 95% CI, 0.856-0.877) performed comparably with the HEART score (0.858; 95% CI, 0.848-0.868). The integration of the AI-ECG improved risk stratification and AMI discrimination, with a net reclassification improvement of 19.6% (95% CI, 17.38-21.89) and a C-index of 0.926 (95% CI, 0.919-0.933), compared with the HEART score alone. CONCLUSIONS: In this multicentre prospective study, the AI-ECG demonstrated diagnostic accuracy and predictive power for AMI and 30 day MACE, which was similar to or better than that of traditional risk stratification methods and ED physicians.

来源:Eur Heart J,查看原文。版权归原作者所有。

引用

  1. Lee, Shin, Lee, et al. Artificial intelligence applied to electrocardiogram to rule out acute myocardial infarction: the ROMIAE multicentre study. Eur Heart J. 2025. PMID: 39992309. doi:10.1093/eurheartj/ehaf004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。