文献速递冠心病心力衰竭与心肌病

臭氧污染与心血管事件住院风险

Ozone pollution and hospital admissions for cardiovascular events.
PubMed 文献 · Eur Heart J · 2023-01-01

该研究采用两阶段多城市时间序列方法,分析2015-17年中国70个城市每日心血管事件住院(n=6 444 441)与臭氧暴露的关联。2日平均每日8小时最大臭氧浓度每升高10 μg/m3,冠心病、急性心肌梗死、心力衰竭、卒中住院风险分别增加0.46%、0.75%、0.50%、0.40%;高臭氧污染日(≥100 μg/m3 vs <70 μg/m3)超额住院风险从卒中3.38%到急性心肌梗死6.52%。结论提示臭氧暴露与心血管事件住院风险增加相关。

要点

  • 臭氧浓度每升高10 μg/m3,急性心肌梗死住院风险增加0.75%(95%CI 0.38%-1.13%)。
  • 高臭氧污染日较对照日,急性心肌梗死超额住院风险达6.52%(95%CI 2.92%-10.24%)。
  • 臭氧暴露与冠心病、心力衰竭、卒中住院风险增加均呈正相关。

核心结论

  • 环境臭氧暴露与心血管事件住院风险增加相关,高臭氧污染日下风险更高。

研究设计与样本

  • 两阶段多城市时间序列研究,覆盖2015-17年中国70个地级及以上城市,每日心血管事件住院共6 444 441例。

主要发现

  • 2日平均每日8小时最大臭氧浓度每升高10 μg/m3,冠心病住院风险增加0.46%(95%CI 0.28%-0.64%)。
  • 每升高10 μg/m3,心绞痛住院风险增加0.45%(95%CI 0.13%-0.77%),急性心肌梗死增加0.75%(95%CI 0.38%-1.13%)。
  • 每升高10 μg/m3,急性冠脉综合征住院风险增加0.70%(95%CI 0.41%-1.00%),心力衰竭增加0.50%(95%CI 0.24%-0.77%)。
  • 每升高10 μg/m3,卒中住院风险增加0.40%(95%CI 0.23%-0.58%),缺血性卒中增加0.41%(95%CI 0.22%-0.60%)。
  • 高臭氧污染日(2日平均8小时最大浓度≥100 μg/m3 vs <70 μg/m3)超额住院风险从卒中3.38%(95%CI 1.73%-5.06%)到急性心肌梗死6.52%(95%CI 2.92%-10.24%)。

临床怎么用

  • 在心血管事件高发时段关注臭氧污染预警,提醒冠心病、心肌梗死、心力衰竭和卒中高风险患者减少户外暴露。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The available literature on morbidity risk of cardiovascular diseases associated with ambient ozone pollution is still limited. This study examined the potential acute effects of exposure to ambient ozone pollution on hospital admissions of cardiovascular events in China. METHODS AND RESULTS: A two-stage multi-city time-series study approach was used to explore the associations of exposure to ambient ozone with daily hospital admissions (n = 6 444 441) for cardiovascular events in 70 Chinese cities of prefecture-level or above during 2015-17. A 10 μg/m3 increment in 2-day average daily 8 h maximum ozone concentrations was associated with admission risk increases of 0.46% [95% confidence interval (CI): 0.28%, 0.64%] in coronary heart disease, 0.45% (95% CI: 0.13%, 0.77%) in angina pectoris, 0.75% (95% CI: 0.38%, 1.13%) in acute myocardial infarction (AMI), 0.70% (95% CI: 0.41%, 1.00%) in acute coronary syndrome, 0.50% (95% CI: 0.24%, 0.77%) in heart failure, 0.40% (95% CI: 0.23%, 0.58%) in stroke and 0.41% (95% CI: 0.22%, 0.60%) in ischemic stroke, respectively. The excess admission risks for these cardiovascular events associated with high ozone pollution days (with 2-day average 8-h maximum concentrations ≥100 µg/m3 vs. < 70 µg/m3) ranged from 3.38% (95% CI: 1.73%, 5.06%) for stroke to 6.52% (95% CI: 2.92%, 10.24%) for AMI. CONCLUSION: Ambient ozone was associated with increased hospital admission risk for cardiovascular events. Greater admission risks for cardiovascular events were observed under high ozone pollution days. These results provide evidence for the harmful cardiovascular effects of ambient ozone and call for special attention on the control of high ozone pollution.

来源:Eur Heart J,查看原文。版权归原作者所有。

引用

  1. Jiang, Huang, Li, et al. Ozone pollution and hospital admissions for cardiovascular events. Eur Heart J. 2023. PMID: 36893798. doi:10.1093/eurheartj/ehad091

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。