ESC 0/1小时算法在已知冠心病患者中的性能评估
本研究为STOP-CP前瞻性多中心队列的预计划亚组分析,纳入1430例疑似急性冠脉综合征患者,评估ESC 0/1小时高敏肌钙蛋白T算法对30天心源性死亡或心肌梗死的诊断性能。已知冠心病患者中该算法排除区阴性预测值仅96.6%,显著低于无冠心病患者的98.9%,且均未达到99%的排除阈值。
要点
- 已知冠心病患者中ESC 0/1小时算法排除区阴性预测值为96.6%,未能达到99%的安全排除标准。
- 已知冠心病患者被归入排除区的比例(39.6%)显著低于无冠心病患者(66.1%)。
- 临床对已知冠心病患者使用该算法排除急性冠脉综合征时应谨慎。
核心结论
- 在已知冠心病患者中,ESC 0/1小时hs-cTnT算法无法安全排除30天心源性死亡或心肌梗死。
- 无冠心病患者中阴性预测值显著更高,但仍低于99%。
研究设计与样本
- STOP-CP前瞻性多中心队列研究的预计划亚组分析,2017年1月25日至2018年9月6日在美国8个急诊科开展。
- 纳入21岁及以上、疑似急性冠脉综合征且初始心电图无ST段抬高的患者,共1430例。
- 根据ESC 0/1小时hs-cTnT算法将患者分为排除区、观察区和纳入区。
主要发现
- 30天内心源性死亡或心肌梗死发生183例(12.8%),已知冠心病449例(31.4%)。
- 已知冠心病患者中178/449(39.6%)被归入排除区,无冠心病患者中648/981(66.1%)被归入排除区(P < .001)。
- 排除区患者中,已知冠心病组30天心源性死亡或心肌梗死发生6/178(3.4%),无冠心病组7/648(1.1%)(P < .001)。
- 已知冠心病组阴性预测值为96.6%(95% CI, 92.8-98.8),无冠心病组为98.9%(95% CI, 97.8-99.6)(P = .04)。
临床怎么用
- 对已知冠心病患者使用ESC 0/1小时hs-cTnT算法排除急性冠脉综合征时应谨慎,因其阴性预测值未达99%阈值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
IMPORTANCE: The European Society of Cardiology (ESC) 0/1-hour algorithm is a validated high-sensitivity cardiac troponin (hs-cTn) protocol for emergency department patients with possible acute coronary syndrome. However, limited data exist regarding its performance in patients with known coronary artery disease (CAD; prior myocardial infarction [MI], coronary revascularization, or ≥70% coronary stenosis). OBJECTIVE: To evaluate and compare the diagnostic performance of the ESC 0/1-hour algorithm for 30-day cardiac death or MI among patients with and without known CAD and determine if the algorithm could achieve the negative predictive value rule-out threshold of 99% or higher. DESIGN, SETTING, AND PARTICIPANTS: This was a preplanned subgroup analysis of the STOP-CP prospective multisite cohort study, which was conducted from January 25, 2017, through September 6, 2018, at 8 emergency departments in the US. Patients 21 years or older with symptoms suggestive of acute coronary syndrome without ST-segment elevation on initial electrocardiogram were included. Analysis took place between February and December 2022. INTERVENTIONS/EXPOSURES: Participants with 0- and 1-hour high-sensitivity cardiac troponin T (hs-cTnT) measures were stratified into rule-out, observation, and rule-in zones using the ESC 0/1-hour hs-cTnT algorithm. MAIN OUTCOMES AND MEASURES: Cardiac death or MI at 30 days determined by expert adjudicators. RESULTS: During the study period, 1430 patients were accrued. In the cohort, 775 individuals (54.2%) were male, 826 (57.8%) were White, and the mean (SD) age was 57.6 (12.8) years. At 30 days, cardiac death or MI occurred in 183 participants (12.8%). Known CAD was present in 449 (31.4%). Among patients with known CAD, the ESC 0/1-hour algorithm classified 178 of 449 (39.6%) into the rule-out zone compared with 648 of 981 (66.1%) without CAD (P < .001). Among rule-out zone patients, 30-day cardiac death or MI occurred in 6 of 178 patients (3.4%) with known CAD and 7 of 648 (1.1%) without CAD (P < .001). The negative predictive value for 30-day cardiac death or MI was 96.6% (95% CI, 92.8-98.8) among patients with known CAD and 98.9% (95% CI, 97.8-99.6) in patients without known CAD (P = .04). CONCLUSIONS AND RELEVANCE: Among patients with known CAD, the ESC 0/1-hour hs-cTnT algorithm was unable to safely exclude 30-day cardiac death or MI. This suggests that clinicians should be cautious if using the algorithm in patients with known CAD. The negative predictive value was significantly higher in patients without a history of CAD but remained less than 99%.
引用
- Ashburn, Snavely, O'Neill, et al. Performance of the European Society of Cardiology 0/1-Hour Algorithm With High-Sensitivity Cardiac Troponin T Among Patients With Known Coronary Artery Disease. JAMA Cardiol. 2023. PMID: 36857071. doi:10.1001/jamacardio.2023.0031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。