PCSK9功能缺失变异与心力衰竭风险无关联
该研究为UK Biobank嵌套病例对照研究,纳入完成心脏磁共振成像且有遗传数据的个体,分析PCSK9功能缺失变异、R46L错义变异及遗传风险评分与心脏结构、功能及心衰诊断的关联,未发现显著关联。
要点
- PCSK9功能缺失变异与左心室质量、射血分数及心衰风险均无显著关联。
- R46L错义变异及遗传风险评分与心脏磁共振指标和心衰也无显著关联。
- 动物研究提示的PCSK9缺乏致心脏重构和心衰的担忧在人类遗传学中未得到支持。
核心结论
- 在人类中,PCSK9遗传变异与心脏结构、功能改变或心衰无关联。
研究设计与样本
- UK Biobank嵌套病例对照研究,纳入完成心脏磁共振成像且有遗传数据的个体。
临床怎么用
- 本研究结果不支持PCSK9功能缺失变异增加心衰风险的担忧。
- 对于使用PCSK9抑制剂的患者,无需基于此遗传学证据额外担忧心衰风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
IMPORTANCE: An animal (mouse) study indicated that deficiency of proprotein convertase subtilisin/kexin type 9 (PCSK9) causes cardiac remodeling and heart failure (HF). Cardiac remodeling after PCSK9-inhibitor treatment is a concern for patients and for development of treatment directed against PCSK9. OBJECTIVE: To determine whether genetic variants in the PCSK9 gene are associated with altered cardiac structure, cardiac function, and HF in humans. DESIGN, SETTING, PARTICIPANTS: This was a nested case-control study within the UK Biobank. Between March 13, 2006, and October 1, 2010, the UK Biobank enrolled 502 480 individuals aged 40 to 69 years. This study focused on a subset of those individuals, who completed cardiac magnetic resonance (CMR) imaging and had available genetic data. Analyses were conducted between November 2, 2021, and October 28, 2022. EXPOSURES: Carrier status of predicted loss-of-function (pLoF) PCSK9 variants, R46L missense variant, and a genetic risk score (GRS). MAIN OUTCOMES AND MEASURES: A total of 11 CMR imaging measurements, generated using a machine learning algorithm, and HF diagnosis. RESULTS: In up to 35 135 individuals with CMR images, 18 252 (52%) were female individuals, and mean (SD) age was 55.0 (7.4) years. No significant association between PCSK9 carrier status and CMR indices were found for left ventricular mass (pLoF: β = -1.01; 95% CI, -2.99 to 0.98; P = .32; R46L: β = -0.18; 95% CI, -0.55 to 0.19; P = .35; GRS: β = -0.19; 95% CI, -0.50 to 0.11; P = .22) and left ventricular ejection fraction (pLoF: β = 0.43; 95% CI, -1.32 to 2.18; P = .63; R46L: β = -0.19; 95% CI, -0.52 to 0.14; P = .26; GRS: β = -0.08; 95% CI, -0.35 to 0.20; P = .58) or HF (pLoF: odds ratio [OR], 1.14; 95% CI, 0.56-2.05; P = .69; R46L: OR, 0.99; 95% CI, 0.90-1.10; P = .91; GRS: OR, 1.04; 95% CI, 0.96-1.13; P = .32). CONCLUSIONS AND RELEVANCE: Results of this case-control study suggest that there was no association between PCSK9 genetic variants and altered cardiac structure, cardiac function, or HF in humans.
引用
- Trudsø, Ghouse, Ahlberg, et al. Association of PCSK9 Loss-of-Function Variants With Risk of Heart Failure. JAMA Cardiol. 2023. PMID: 36542369. doi:10.1001/jamacardio.2022.4798
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。