设备测量的体力活动与心衰发病风险:英国生物银行94 739人前瞻性队列研究
该研究基于英国生物银行94 739名无心肌梗死和心衰的参与者,采用腕戴加速度计测量体力活动,中位随访6.1年。结果显示,与无中高强度体力活动者相比,每周150-300分钟中等强度体力活动者心衰风险降低(HR 0.37,95%CI 0.34-0.41),每周75-150分钟高强度体力活动者心衰风险也降低(HR 0.34,95%CI 0.25-0.46)。高强度体力活动与心衰风险呈反向J型关联,超过每周150分钟后风险降低幅度可能减小。
要点
- 设备测量的中等强度体力活动每周150-300分钟与心衰风险显著降低相关。
- 高强度体力活动每周75-150分钟也与心衰风险降低相关,但超过150分钟/周风险降低幅度可能减小。
- 当前高强度体力活动推荐应鼓励但不应增加,增加中等强度体力活动可能有益。
核心结论
- 设备测量的体力活动,尤其是中等强度体力活动,与较低的心衰风险相关。
研究设计与样本
- 前瞻性队列研究,纳入94 739名英国生物银行参与者,2013-2015年进行设备测量的体力活动,基线无心肌梗死和心衰。
主要发现
- 中位随访6.1年,心衰总发病率为每10 000人年98.5例。
- 与无中高强度体力活动者相比,每周150-300分钟中等强度体力活动者心衰风险HR为0.37(95%CI 0.34-0.41)。
- 与无中高强度体力活动者相比,每周75-150分钟高强度体力活动者心衰风险HR为0.34(95%CI 0.25-0.46)。
- 高强度体力活动与心衰风险的关联呈反向J型,超过每周150分钟后风险降低可能减弱。
临床怎么用
- 当前高强度体力活动推荐应鼓励但不应增加,增加中等强度体力活动可能有益,即使在已达到当前推荐水平的人群中。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Studies of objectively measured physical activity (PA) have investigated acute cardiovascular outcomes but not heart failure (HF), an emerging chronic condition. This study aimed to investigate the dose-response relationship between device-measured PA and HF by intensity of PA. METHODS: This was a prospective cohort study of 94 739 UK Biobank participants who had device-measured PA in 2013 to 2015 and were free from myocardial infarction and HF. PA was measured with a wrist-worn accelerometer, and time spent on light-, moderate-, and vigorous-intensity PA was extracted. Incident HF was ascertained from linked hospital and death records. Cox proportional hazard models with cubic penalized splines were used to study the associations, which were adjusted for sociodemographic and lifestyle factors. Competing risk was handled with cause-specific hazard ratios. RESULTS: The overall incidence of HF was 98.5 per 10 000 person-years over a median 6.1 years of follow-up. Compared with participants who undertook no moderate- to vigorous-intensity PA, those who performed 150 to 300 min/wk of moderate-intensity PA (hazard ratio, 0.37 [95% CI, 0.34-0.41]) and 75 to 150 min/wk of vigorous-intensity PA (hazard ratio, 0.34 [95% CI, 0.25-0.46]) were at lower HF risk. The association between vigorous-intensity PA and HF was reverse-J shaped with a potentially lower risk reduction above 150 min/wk. CONCLUSIONS: Device-measured PA, especially moderate-intensity PA, was associated with a lower risk of HF. Current vigorous-intensity PA recommendations should be encouraged but not increased. In contrast, increasing moderate-intensity PA may be beneficial even among those meeting current recommendations.
引用
- Ho, Zhou, Petermann-Rocha, et al. Association Between Device-Measured Physical Activity and Incident Heart Failure: A Prospective Cohort Study of 94 739 UK Biobank Participants. Circulation. 2022. PMID: 36036153. doi:10.1161/CIRCULATIONAHA.122.059663
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。