文献速递冠心病

切割球囊 rescue 治疗重度钙化颈动脉狭窄:病例报告与文献综述

Rescue Cutting Balloon Angioplasty for Heavily Calcified Carotid Artery Stenosis: A Case Report and Narrative Review
RSS 订阅 · Catheterization and Cardiovascular Interventions · 2026-09-30

报告一例83岁男性症状性颈动脉重度钙化狭窄(HCLs),造影示91%狭窄、最小管腔直径(MLD)0.4 mm。标准预扩张导致狗骨畸形(残余狭窄74%、MLD 1.1 mm),支架无法输送;改用3.0 mm Wolverine冠脉切割球囊成功将MLD增至2.4 mm,无血流动力学不稳,随后成功植入自膨支架,后扩张后残余狭窄19%。术后第4天亚急性支架内血栓经强化抗栓治疗完全消失,3个月随访无卒中或再狭窄,mRS评分2。文献支持新一代切割球囊是顽固性颈动脉HCLs安全有效的救援策略。

要点

  • 重度钙化颈动脉狭窄标准预扩张可能失败,切割球囊可作救援手段
  • 3.0 mm Wolverine切割球囊将MLD从1.1增至2.4 mm,避免血流动力学不稳
  • 支架植入后残余狭窄19%,3个月无卒中且支架内血栓经抗栓治疗消失

核心结论

  • 新一代切割球囊改善通过外径,对顽固性颈动脉重度钙化狭窄是一种安全有效的救援策略,可获得必要的管腔增益并减少操作风险

研究设计与样本

  • 病例报告附叙述性文献回顾
  • 单例患者为83岁男性症状性颈动脉重度钙化狭窄

主要发现

  • 标准预扩张致狗骨畸形,残余狭窄74%、MLD 1.1 mm,支架无法输送
  • 3.0 mm Wolverine切割球囊成功将MLD增至2.4 mm,未引起压力感受器介导的血流动力学不稳
  • 自膨支架植入并后扩张后,最终残余狭窄19%
  • 术后第4天亚急性支架内血栓经强化抗栓治疗后完全消退,3个月随访无卒中复发或支架内再狭窄,mRS评分2

关键数值与推荐

  • 造影示91%狭窄,MLD 0.4 mm
  • 预扩张后残余狭窄74%,MLD 1.1 mm
  • 切割球囊后MLD达2.4 mm
  • 最终残余狭窄19%
  • 3个月随访mRS评分为2

临床怎么用

  • 当颈动脉重度钙化病变标准预扩张失败时,可考虑使用冠脉切割球囊进行救援性血管成形
  • 切割球囊扩张虽为救援手段,但仍需配合标准支架植入及后扩张完成血运重建
  • 术后需强化抗栓治疗以应对可能的亚急性支架内血栓风险

局限性

  • 单例个案报告,缺乏对照及大样本验证
  • 文献综述部分未系统检索,可能遗漏相关证据
  • 长期疗效及安全性超过3个月随访期未报告

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

ABSTRACT Carotid artery stenting for heavily calcified lesions (HCLs) poses significant therapeutic challenges. We report an 83-year-old male with symptomatic carotid stenosis of HCLs. Angiography demonstrated 91% stenosis with a minimum lumen diameter (MLD) of 0.4 mm. Standard pre-dilation resulted in a “dog-bone” deformity (residual stenosis 74%, MLD 1.1 mm), preventing stent delivery. As a rescue technique, a 3.0 mm Wolverine coronary cutting balloon (Boston Scientific, Marlborough, MA, USA) was employed, successfully increasing the MLD to 2.4 mm without inducing baroreceptor-mediated hemodynamic instability. This luminal gain facilitated the successful delivery and deployment of a self-expanding stent, followed by post-dilation that achieved a final residual stenosis of 19%. A subacute in-stent thrombus detected on post-procedure day 4 resolved completely with intensified antithrombotic therapy, and at 3-month follow-up the patient had no recurrent stroke or in-stent restenosis, with a modified Rankin Scale score of 2. Supported by a literature review, this case demonstrates that newer-generation cutting balloons with improved crossing profiles offer a safe, effective rescue strategy for unyielding carotid HCLs, achieving essential luminal gain while minimizing procedural risks.

来源:Catheterization and Cardiovascular Interventions,查看原文。版权归原作者所有。

引用

  1. Catheterization and Cardiovascular Interventions:Rescue Cutting Balloon Angioplasty for Heavily Calcified Carotid Artery Stenosis: A Case Report and Narrative Review

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。