文献速递冠心病

限制性上腔静脉-左心房交通合并大量左向右分流:一种既往未描述的静脉窦型缺损变异

Restrictive Superior Vena Cava to Left Atrium Communication With a Large Left‐to‐Right Shunt: A Previously Undescribed Sinus Venosus Defect Variant
RSS 订阅 · Catheterization and Cardiovascular Interventions · 2026-09-28

报道一例40岁女性,因晕厥就诊,发现右心室扩大、部分肺静脉异位连接及静脉窦型缺损。经食管超声显示右上及右中肺静脉异位引流入右上腔静脉,并存在左上腔静脉引流入冠状静脉窦。心内交通仅为上腔静脉与左心房之间的限制性小开窗。有创血流动力学证实大量左向右分流(Qp:Qs 3.3:1),肺动脉压正常(平均19 mmHg)。球囊探查显示限制性交通及球囊脱入肺静脉伴梗阻,不适合经导管矫正,遂行外科手术修复。

要点

  • 此变异中房间隔交通限制性,但大量分流由异位肺静脉连接承担
  • 需注意与传统SVD不同,评估经导管矫正可行性时应用球囊探查
  • 正常肺动脉压下大量分流提示需手术修复,本例不适合介入

核心结论

  • 报道一种既往未描述的静脉窦型缺损变异,其房间隔交通为限制性,但大量左向右分流经异位肺静脉连接输送
  • 该变异对经导管与手术决策有重要影响,本例因限制性交通及球囊脱入肺静脉梗阻不适合经导管矫正

研究设计与样本

  • 单个病例报告,对象为40岁女性患者
  • 患者以晕厥为首发表现,后经影像学、经食管超声及有创血流动力学评估

主要发现

  • 超声显示右心室及肺动脉扩张,轻度三尖瓣反流,右上及右中肺静脉异位引流入右上腔静脉
  • 存在持续左上腔静脉引流入扩张的冠状静脉窦
  • 房间隔交通为上腔静脉与左心房之间的小而限制性开窗
  • 有创血流动力学证实大量左向右分流,Qp:Qs为3.3:1
  • 肺动脉平均压19 mmHg,属正常范围

关键数值与推荐

  • Qp:Qs为3.3:1,对应左向右分流
  • 平均肺动脉压19 mmHg
  • 球囊探查示限制性交通,顺应性球囊脱入肺静脉伴明显梗阻,提示不适合经导管矫正

临床怎么用

  • 面对类似病例,需仔细评估解剖细节,识别此限制性交通变异
  • 使用球囊探查评估经导管矫正可行性,若出现球囊脱入肺静脉伴梗阻则应选择外科手术
  • 尽管肺压正常,大量分流仍提示需要干预

局限性

  • 单病例报告,结论外推需谨慎

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

ABSTRACT A 40-year-old woman was referred for cardiac assessment following a syncopal event. Echocardiography showed a dilated right ventricle and subsequent cross-sectional imaging suggested partial anomalous pulmonary venous connection (PAPVC) and a sinus venosus defect (SVD). She reported exertional dyspnoea, fatigue, paroxysmal nocturnal dyspnoea, longstanding palpitations, and documented runs of atrial tachycardia. Transoesophageal echocardiography demonstrated a dilated right ventricle and pulmonary arteries, mild tricuspid regurgitation, anomalous connection of the right upper and right middle pulmonary veins to the right superior vena cava (SVC), and a persistent left SVC draining to a dilated coronary sinus. Unusually, the interatrial communication consisted of only a small, restrictive fenestration between the SVC and the left atrium. Invasive haemodynamics confirmed a large left-to-right shunt (Qp:Qs 3.3:1) with normal pulmonary artery pressure (mean 19 mmHg). Balloon interrogation demonstrated a restrictive communication and prolapse of the compliant balloon into the pulmonary veins with apparent obstruction, indicating unsuitability for transcatheter correction; the patient underwent surgical repair. We report a previously undescribed SVD in which the interatrial communication is restrictive despite a large shunt carried by the anomalous venous connection and discuss its implications for transcatheter versus surgical decision-making.

来源:Catheterization and Cardiovascular Interventions,查看原文。版权归原作者所有。

引用

  1. Catheterization and Cardiovascular Interventions:Restrictive Superior Vena Cava to Left Atrium Communication With a Large Left‐to‐Right Shunt: A Previously Undescribed Sinus Venosus Defect Variant

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。