本文报道两例经皮冠状动脉介入治疗中导丝头端嵌顿、核心断裂后弹簧圈沿主动脉延伸解旋的病例。两例均采用一种新型圈套器回收技术成功完整取出弹簧圈丝。研究者并通过实验室台架测试评估该技术的物理基础,以支持其可重复性。

要点

  • PCI中导丝嵌顿断裂虽不常见,但复杂病变中需警惕弹簧圈解旋栓塞风险。
  • 圈套器回收技术可完整取出沿主动脉延伸的解旋弹簧圈丝。
  • 处理策略仍取决于术者,可选择留置异物或紧急外科手术。

核心结论

  • 两例PCI导丝核心断裂后弹簧圈沿主动脉解旋的并发症均通过新型圈套器回收技术成功完整取出。
  • 该技术经实验室台架测试验证其物理基础,提示具有可重复性。

研究设计与样本

  • 本文为两例PCI并发症的病例报告。
  • 研究者对所用回收技术进行实验室台架测试以评估其物理基础。

主要发现

  • 两例PCI均发生导丝头端嵌顿,进而导致核心断裂。
  • 核心断裂后弹簧圈解旋并沿主动脉向深部延伸。
  • 两例均采用一种新型圈套器回收技术完整取出全部弹簧圈丝。

关键数值与推荐

  • 病例回收方法为一种用于完整取出解旋弹簧圈丝的新型圈套器回收技术。

临床怎么用

  • PCI中遇到导丝核心断裂伴弹簧圈解旋延伸时,可考虑使用该圈套器回收技术。
  • 复杂PCI场景中应警惕导丝嵌顿及断裂风险。

局限性

  • 管理策略仍取决于术者偏好,缺乏统一标准。
  • 本文仅基于两例病例报告,实验室台架测试结果对临床场景的代表性有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

ABSTRACT Guidewire entrapment and fracture is an uncommon but potentially hazardous event during percutaneous coronary intervention (PCI), and may lead to thrombosis, vessel occlusion, and embolization. In clinical practice interventional cardiologists are aware that such complication is not that rare, especially in complex PCI scenarios. However, its management is still left to the operator's preferences, with individual choices ranging from leaving the fragment in place to urgent cardiac surgery. We report two cases of PCI complicated by entrapment of the guidewire tip, leading to the fracture of the core and subsequent unraveling of the coil that extended deeply along the aorta. Both cases were solved with a novel bailout technique for controlled retrieval of the entire coil filament. The physical bases of such a technique was assessed with laboratory bench tests to extend the reproducibility beyond the two reported cases.