文献速递心律失常

脉冲电场消融用于肺静脉隔离后复发房性心律失常再次消融的疗效与安全性

Efficacy and Safety of Pulsed Field Ablation During Repeat Procedures for Treatment of Recurrent Atrial Arrhythmias After Pulmonary Vein Isolation
RSS 订阅 · Journal of Cardiovascular Electrophysiology · 2026-07-23

本研究比较脉冲电场消融(PFA)与射频消融(RFA)用于肺静脉隔离后复发房性心律失常的再次消融。共纳入320例患者,其中PFA组200例、RFA组120例。PFA组消融范围更广、手术时间更短,但1年无房性心律失常复发率与RFA组相当。

要点

  • PFA再次消融的手术时间显著短于RFA,主要并发症发生率低。
  • PFA组肺静脉、后壁和上腔静脉隔离均100%由PFA单独完成。
  • PFA组1年无复发率与RFA组相似,更广消融未带来额外获益。

核心结论

  • 使用五瓣花型导管进行PFA再次消融相比RFA消融范围更广、并发症率低,但未提高无房颤复发率。

研究设计与样本

  • 回顾性比较320例接受再次消融的患者,PFA组200例,RFA组120例,平均年龄71±11岁,男性61%。

主要发现

  • 基线肺静脉再连接率两组相当。
  • PFA组靶向肺静脉、后壁和上腔静脉消融的患者比例显著高于RFA组。
  • PFA组中肺静脉、后壁和上腔静脉隔离由PFA单独完成的成功率为100%。
  • 前壁线31%和二尖瓣峡部线50%的PFA病例需要辅助RFA才能达到传导阻滞。
  • PFA组手术时间显著短于RFA组。

关键数值与推荐

  • 主要并发症率:PFA组0%,RFA组1.7%,p=0.067。
  • 1年无房性心律失常复发率:PFA组59%,RFA组56%,log-rank p=0.71。
  • 前壁线需辅助RFA比例31%,二尖瓣峡部线需辅助RFA比例50%。

临床怎么用

  • 对于肺静脉隔离后复发的房性心律失常,PFA可作为再次消融的安全选择,手术时间更短。
  • 若PFA用于前壁线或二尖瓣峡部线消融,需准备辅助RFA以完成传导阻滞。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Use of pulsed field ablation for repeat AF ablation was associated with more extensive ablation, shorter procedure times with a low complication rate compared to radiofrequency ablation. Despite more non-PV ablation with PFA, freedom from atrial arrhythmia recurrence after repeat procedures was comparable between PFA and RFA groups. ABSTRACT Background Little is known about the efficacy and safety of pulsed field ablation (PFA) for repeat ablation procedures for patients with recurrent atrial fibrillation (AF) after pulmonary vein (PV) isolation. Objective The purpose of this study was to evaluate and compare the efficacy and safety of PFA using a pentaspline ablation catheter with radiofrequency ablation (RFA) in repeat ablation procedures for atrial arrhythmia. Methods We compared 320 patients (mean age 71 ± 11 years, 61% male) who underwent repeat ablation procedures with PFA and RFA. Procedural data, including lesion set-specific acute success, safety endpoints, and recurrence of atrial arrhythmia were compared between groups. Results Overall, 200 and 120 patients were treated with PFA and RFA during repeat ablation, respectively. Although the rate of baseline PV reconnection was comparable between groups, PV, posterior wall, and superior vena cava ablation were targeted in significantly more patients in the PFA group compared to the RFA group. In the PFA group, PV, posterior wall, and superior vena cava isolation were successfully achieved by PFA alone in 100% cases. Adjunctive RFA was required in 31% of anterior wall and 50% of lateral mitral isthmus PFA cases to achieve line of block. Procedure times were significantly shorter in the PFA group. Major complication rates were comparable between the groups (PFA vs. RFA, 0% vs. 1.7%, p = 0.067). Freedom from atrial arrhythmia recurrence at 1 year was similar between PFA and RFA groups (59% vs. 56%; log-rank p = 0.71). Conclusion Use of PFA with a pentaspline catheter for repeat AF ablation was associated with more extensive ablation compared to RFA with low complication rates but did not result in increased freedom from AF recurrence.

来源:Journal of Cardiovascular Electrophysiology,查看原文。版权归原作者所有。

引用

  1. Journal of Cardiovascular Electrophysiology:Efficacy and Safety of Pulsed Field Ablation During Repeat Procedures for Treatment of Recurrent Atrial Arrhythmias After Pulmonary Vein Isolation

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。