文献速递心律失常

持续性房颤驱动区的电压特征:电压移行带内的马赛克模式

Identifying Driver Regions in Persistent Atrial Fibrillation: A Mosaic Pattern Within the Atrial Voltage Transition Zone
RSS 订阅 · Journal of Cardiovascular Electrophysiology · 2026-07-16

本研究基于201例持续性房颤患者的多中心回顾性探索队列,分析241个驱动区的电压特征,提出最佳电压移行带(0.16–0.61 mV)可识别78.8%的驱动区,且驱动区常表现为低电压、移行区和正常电压交界处的马赛克模式。,在53例前瞻性验证队列中,采用该电压阈值引导消融,急性终止率(69.8%)与12个月无房性心律失常率与探索队列相当,但无房颤率较低(p=0.035),复发中房颤比例减少(p=0.009),手术时间及消融驱动区数量亦减少。

要点

  • 驱动区常见于低电压、移行区与正常电压交界处的马赛克模式
  • 马赛克模式识别敏感性94.2%,特异性77.1%,优于传统低电压区方法

核心结论

  • 持续性房颤驱动区在优化电压阈值下常呈现马赛克模式,可作为心电图标测的辅助手段;是否改善临床结局尚待确定

研究设计与样本

  • 多中心回顾性探索队列(201例PsAF患者,241个驱动区)
  • 前瞻性验证队列(53例患者)
  • 探索队列分析驱动区电压特征以推导最佳电压移行带,验证队列采用该映射引导消融

主要发现

  • 最佳电压阈值(0.16–0.61 mV)识别驱动区的比例为78.8%
  • 驱动区常在低电压、移行区、正常电压交界处呈马赛克模式
  • 马赛克模式识别敏感性94.2%,特异性77.1%
  • 验证队列中,无房颤率较探索队列低(p=0.035),但复发中房颤比例减少(p=0.009)

关键数值与推荐

  • 最佳电压阈值范围:0.16–0.61 mV
  • 两阈值马赛克模式识别:敏感性94.2%,特异性77.1%
  • 传统低电压区识别驱动区比例42.3%(p=0.004)

临床怎么用

  • 可采用电压移行带阈值(0.16–0.61 mV)识别潜在驱动区,辅助驱动区消融靶点选择
  • 马赛克模式可识别多数急性未终止病例中的驱动区(87.5%)

局限性

  • 该研究为探索性假设提出,临床结局改善尚待随机对照验证

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

ABSTRACT Background and Aims Driver-targeted ablation is a potential adjunct to pulmonary vein isolation (PVI) in persistent atrial fibrillation (PsAF), yet identifying drivers remains challenging. This study investigates whether voltage characteristics can facilitate driver identification. Methods In a multicenter retrospective exploratory cohort of 201 patients with PsAF undergoing PVI plus driver ablation, voltage characteristics within 241 driver regions were analyzed to derive an optimal voltage transition zone. A prospective validation cohort of 53 patients subsequently underwent ablation guided by this mapping approach. Results The optimal voltage threshold (0.16–0.61 mV) captured 78.8% of driver regions, which frequently exhibited a mosaic pattern at the interface of low-, transition-, and normal-voltage areas. This approach outperformed conventional low-voltage area–based identification (42.3%, p = 0.004). Mosaic pattern recognition using two voltage thresholds achieved 94.2% sensitivity and 77.1% specificity. Among cases without acute AF termination, the mosaic pattern was still observed in 87.5% of driver regions. In the validation cohort, acute AF termination (69.8%) and 12-month freedom from atrial arrhythmias were comparable to the exploratory cohort, though freedom from AF was lower (p = 0.035) but AF proportion among recurrences was reduced (p = 0.009). Procedure time and number of drivers ablated were also decreased (p = 0.001 and 0.003, respectively). Conclusion This work proposes a hypothesis that AF driver regions in PsAF frequently exhibit a mosaic pattern under optimized voltage thresholds, which may provide a feasible adjunct to electrogram-guided mapping; whether this approach improves clinical outcomes remains to be determined.

来源:Journal of Cardiovascular Electrophysiology,查看原文。版权归原作者所有。

引用

  1. Journal of Cardiovascular Electrophysiology:Identifying Driver Regions in Persistent Atrial Fibrillation: A Mosaic Pattern Within the Atrial Voltage Transition Zone

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。