文献速递心律失常

超声引导与常规静脉穿刺用于心房颤动消融的 ULYSSES 试验

Ultrasound-guided vs conventional venous puncture for atrial fibrillation ablation: the ULYSSES trial.
PubMed 文献 · Eur Heart J · 2026-01-01

ULYSSES 试验纳入 986 例接受心房颤动或左心房心动过速导管消融的患者,随机比较超声引导股静脉穿刺与触诊引导常规穿刺。试验在入组计划一半患者后因疗效显著提前终止。超声引导组 30 天静脉穿刺部位复合并发症发生率为 0.6%,显著低于常规组的 3.3%(P = .002)。

要点

  • 超声引导显著减少误穿动脉和需要交叉换组的失败穿刺。
  • 该结果支持在房颤消融中优先采用超声引导静脉穿刺策略。

核心结论

  • 超声引导静脉穿刺用于心房颤动消融可显著降低血管穿刺部位并发症。

研究设计与样本

  • 研究者发起、多中心、开放标签、优效性随机对照试验,计划纳入接受房颤或左心房心动过速导管消融的患者。
  • 在 6 个中心共随机 986 例患者,其中超声引导组 496 例,常规穿刺组 490 例。
  • 试验在入组计划患者数一半后的首次期中分析因疗效显著而提前终止。
  • 随机比较超声引导股静脉穿刺策略与触诊引导常规穿刺策略。

主要发现

  • 超声引导组复合主要结局发生率为 0.6%(3/496),常规组为 3.3%(16/490),风险比为 0.19,95% 置信区间 0.05-0.63,P = .002。
  • 超声引导组非预期动脉穿刺率为 2%,常规组为 16%,P < .0001。
  • 超声引导组需要交叉至另一组的静脉穿刺失败率为 0.2%,常规组为 8.2%,P < .0001。

关键数值与推荐

  • 复合主要结局定义为术后 30 天内发生动静脉瘘、假性动脉瘤或需要干预或导致住院延长的穿刺部位出血。
  • 次要终点包括操作时长、穿刺时长、30 天内操作相关卒中/短暂性脑缺血发作、非预期动脉穿刺次数、静脉穿刺失败次数及住院时长。

临床怎么用

  • 对于接受房颤或左心房心动过速导管消融的患者,可考虑常规采用超声引导股静脉穿刺以降低血管穿刺并发症。

局限性

  • 试验采用开放标签设计,未对操作者设盲。
  • 因期中分析显示疗效显著而提前终止,实际样本量为计划样本量的一半。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Vascular access site complications are the most common procedure-related adverse event of atrial fibrillation catheter ablation. Whether ultrasound-guided femoral venous puncture reduces these vascular access complications remains uncertain. METHODS: In this investigator-initiated, multicentre, open-label, superiority trial, patients undergoing atrial fibrillation or left atrial tachycardia catheter ablation were randomized to an ultrasound-guided venous puncture strategy (intervention group) or to a conventional venous puncture group guided by palpation (control group). The composite primary outcome was the occurrence of venous access site complications until 30 days after the procedure, defined as arteriovenous fistula, false aneurysm, or access site bleeding requiring intervention or leading to prolonged hospitalization. Secondary endpoints included procedure duration, puncture duration, procedure-related stroke/transient ischaemic attack within 30 days, number of unintended arterial punctures, and number of failed venous access attempts, as well as hospital stay duration. RESULTS: In six centres, 986 patients were randomized. A total of 496 patients were assigned to the ultrasound-guided puncture group, and 490 patients to the conventional puncture group. The trial was stopped for efficacy, following the first interim analysis after enrolment of half of the planned patients. The composite primary outcome occurred in 3 patients (0.6%) in the intervention group and 16 patients (3.3%) in the control group (risk ratio 0.19; 95% confidence interval 0.05-0.63; P = .002). Additionally, ultrasound-guided venous puncture significantly reduced the rate of an unintended arterial puncture (2% vs 16%, P < .0001) and the rate of unsuccessful venous access attempts requiring crossover to the other group (0.2% vs 8.2%, P < .0001). CONCLUSIONS: Ultrasound-guided venous access for atrial fibrillation ablation procedures significantly reduced vascular access site complications. ULYSSES CLINICALTRIALS.GOV NUMBER: NCT06403527.

来源:Eur Heart J,查看原文。版权归原作者所有。

引用

  1. Schaack, Chun, Neven, et al. Ultrasound-guided vs conventional venous puncture for atrial fibrillation ablation: the ULYSSES trial. Eur Heart J. 2026. PMID: 41979041. doi:10.1093/eurheartj/ehag291

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。