术前CT引导可提高起搏器右心室间隔部导线植入准确性
该研究回顾性分析501例因心动过缓接受首次双腔起搏器植入的患者,比较术前CT引导与非CT引导的右心室导线植入结果。CT引导组的间隔部导线植入率更高,放射剂量更低,完全性房室传导阻滞患者术后起搏QRS时限更短。两组总手术时间、透视时间和起搏参数相当,CT引导组囊袋血肿发生率更低。
要点
- 术前CT多平面重建可预先确定右心室中间隔靶点,并投影到定位像上引导导线植入。
- CT引导组间隔部植入率93.0%,显著高于非CT引导组的55.6%。
- CT引导不延长手术时间,且放射剂量更低,囊袋血肿更少见。
核心结论
- 术前CT引导通过定位像实现右心室导线靶点的精确规划,可在不延长手术时间或影响电学性能的情况下实现可重复的间隔部植入。
研究设计与样本
- 回顾性分析501例因心动过缓接受首次双腔起搏器植入的连续患者,其中非CT引导组243例,CT引导组258例。
- CT引导组术前通过CT多平面重建确定中间隔靶点,并将参考线投影到定位像上引导导线植入。
主要发现
- CT引导组间隔部导线植入率高于非CT引导组(93.0% vs. 55.6%,p < 0.001),游离壁植入率更低(7.0% vs. 44.4%,p < 0.001)。
- CT引导组手术放射剂量低于非CT引导组(100.2 ± 124.6 mGy vs. 169.1 ± 152.4 mGy;p < 0.001)。
- 在完全性房室传导阻滞且有术后起搏QRS测量值的303例患者中,CT引导组QRS时限短于非CT引导组(145.3 ± 22.3 ms vs. 155.4 ± 19.0 ms,p < 0.001)。
- CT引导组囊袋血肿发生率低于非CT引导组(0.4% vs. 2.9%,p = 0.03)。
关键数值与推荐
- 多变量校正后,CT引导与间隔部植入的关联仍然存在(校正OR,10.30;95% CI,5.91–17.97;p < 0.001)。
- 两组总手术时间、透视时间和起搏参数相当。
临床怎么用
- 对于计划行右心室间隔部起搏的患者,可考虑术前CT多平面重建确定靶点并投影到定位像,以提高植入准确性并降低放射暴露。
局限性
- 回顾性单中心设计,可能存在选择偏倚和未知混杂因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
ABSTRACT Introduction Accurate right ventricular septal lead placement is crucial for optimal pacemaker performance and procedural safety, yet conventional fluoroscopy-guided implantation is limited by inter-individual anatomical variability. We therefore examined whether preprocedural computed tomography (CT) can provide patient-specific anatomical guidance to enable precise lead positioning. Methods and Results We retrospectively analyzed 501 consecutive patients who underwent initial dual-chamber pacemaker implantation for bradycardia pacing (non-CT-guided, n = 243; CT-guided, n = 258). In the CT-guided group, the midseptal target was determined preoperatively using multiplanar reconstruction of CT images, and reference lines were projected onto the scout image to guide lead placement. We evaluated the total procedure time, fluoroscopy time, right ventricular lead electrical parameters, implantation site, and complications. CT guidance was associated with a higher rate of septal lead placement than non-CT guidance (93.0% vs. 55.6%, p < 0.001), whereas free-wall lead placement was less frequent (7.0% vs. 44.4%, p < 0.001). The procedural radiation dose was lower with CT guidance (CT-guided, 100.2 ± 124.6 mGy vs. non-CT-guided, 169.1 ± 152.4 mGy; p < 0.001). Among patients with complete atrioventricular block and available postoperative paced QRS measurements (n = 303), QRS duration was shorter in the CT-guided group than in the non-CT-guided group (145.3 ± 22.3 ms [n = 165] vs. 155.4 ± 19.0 ms [n = 138], p < 0.001). The association persisted after multivariable adjustment ((adjusted OR, 10.30; 95% CI, 5.91–17.97; p < 0.001). The total procedure time, fluoroscopy time, and pacing parameters were comparable between the groups. Complication rates were low overall, and pocket hematoma was less frequent in the CT-guided group (0.4% vs. 2.9%, p = 0.03). Conclusion Preprocedural CT guidance facilitated precise planning of the right ventricular lead target using scout images and was associated with accurate and reproducible placement at the intended septal site without prolonging procedural time or compromising electrical performance. This approach may represent a practical strategy for optimizing lead placement in bradycardia pacing.
引用
- Journal of Cardiovascular Electrophysiology:Preprocedural Computed Tomography Guidance Improves Accuracy of Right Ventricular Septal Lead Placement in Pacemaker Implantation
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。