房颤节律下倒置T波与后续心脏事件的关联
本研究基于日本社区前瞻性Fushimi AF Registry,纳入2709例基线心电图可用的房颤患者,探讨房颤节律下倒置T波对心脏死亡、心肌梗死和心衰住院复合终点的预测价值。中位随访5.0年,倒置T波患者复合心脏终点发生率显著更高(5.8% vs 3.3%每患者年,log-rank p<0.01),多变量分析显示倒置T波是复合终点的独立预测因子(HR 1.53,95%CI 1.26-1.85,p<0.01)。
要点
- 房颤节律下倒置T波常见,41.4%的基线心电图存在倒置T波
- 倒置T波与复合心脏终点风险独立相关(HR 1.53,95%CI 1.26-1.85)
- 倒置T波部位(前壁、下壁、侧壁)与复合终点风险无关
核心结论
- 房颤节律下倒置T波是复合心脏终点(心脏死亡、心肌梗死、心衰住院)的独立预测因子。
研究设计与样本
- 基于日本社区前瞻性Fushimi AF Registry,纳入2709例基线心电图可用的房颤患者,中位随访5.0年。
主要发现
- 倒置T波组复合心脏终点发生率为5.8%每患者年,无倒置T波组为3.3%每患者年(log-rank p<0.01)。
- 多变量分析显示倒置T波预测复合心脏终点的HR为1.53(95%CI 1.26-1.85,p<0.01)。
- 倒置T波在前壁导联检出率15.7%,下壁导联19.8%,侧壁导联26.6%,部位与复合终点风险无关。
关键数值与推荐
- 基线心电图平均心率94.7次/分,室内传导延迟、ST段压低和倒置T波分别占15.8%、24.7%和41.4%。
临床怎么用
- 房颤患者基线心电图出现倒置T波时,提示后续心脏事件风险升高,可考虑加强风险分层与随访。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The clinical significance of ECG abnormalities during atrial fibrillation (AF) rhythm is poorly understood. The aim of the current study was to explore the impact of inverted T wave on cardiac prognosis in patients with AF. METHODS: The current study enrolled 2709 patients with AF whose baseline ECG was available from a Japanese community-based prospective survey, the Fushimi AF Registry, and the impact of inverted T wave in baseline ECG at AF rhythm on the composite of cardiac death, myocardial infarction and hospitalisation due to heart failure was examined. RESULTS: Intraventricular conduction delay, ST segment depression and inverted T wave were observed in 15.8%, 24.7% and 41.4% of baseline ECG with a mean heart rate of 94.7 beats per minute. The median follow-up duration was 5.0 years. The incidence rate of the composite cardiac endpoint was significantly higher in patients with inverted T wave than those without (5.8% vs 3.3% per patient-year, log-rank p<0.01). The higher risk associated with inverted T wave was consistent even for individual components of the composite cardiac endpoint. By multivariable analysis, inverted T wave was an independent predictor of the composite cardiac endpoint (HR 1.53, 95% CI 1.26 to 1.85, p<0.01). Inverted T wave was detected in 15.7% at anterior leads, 19.8% at inferior leads and 26.6% at lateral leads. The location of inverted T wave was not associated with risk of composite cardiac endpoint. CONCLUSIONS: Inverted T wave was commonly observed in patients with AF and its presence during AF rhythm was associated with subsequent cardiac events.
引用
- Kawaji T, Ogawa H, Hamatani Y, et al. Association of inverted T wave during atrial fibrillation rhythm with subsequent cardiac events. Heart. 2021. PMID: 34039678. doi:10.1136/heartjnl-2021-319199
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。