文献速递瓣膜病与结构性心脏病

人工智能心电图筛查主动脉瓣狭窄

Electrocardiogram screening for aortic valve stenosis using artificial intelligence.
PubMed 文献 · Eur Heart J · 2021-01-01

测试集AUC为0.85,敏感度78%、特异度74%、准确率74%;加入年龄和性别后AUC升至0.87,无高血压患者中达0.90。假阳性患者15年内发生中重度AS风险为真阴性者的2.18倍。

要点

  • AI-ECG可识别中重度主动脉瓣狭窄,测试集AUC 0.85。
  • 加入年龄和性别后AUC升至0.87,无高血压者达0.90。
  • 假阳性者15年内发生中重度AS风险为真阴性者的2.18倍。

核心结论

  • AI-ECG能够识别中重度主动脉瓣狭窄患者,可能成为社区AS筛查的有力工具。

主要发现

  • 测试集中AI-ECG标记3833例(3.7%)为阳性,AUC为0.85。
  • 敏感度78%、特异度74%、准确率74%。
  • 敏感度随年龄增加而升高、特异度随年龄增加而降低;女性各年龄组敏感度低于男性但特异度高于男性。
  • 加入年龄和性别后模型AUC为0.87,无高血压患者中AUC进一步升至0.90。
  • 假阳性AI-ECG患者15年内发生中重度AS的风险为真阴性者的2.18倍(95%CI 1.90-2.50)。

临床怎么用

  • AI-ECG可作为社区筛查工具,用于识别中重度主动脉瓣狭窄患者。
  • 假阳性结果提示未来15年中重度AS风险升高,需加强随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Early detection of aortic stenosis (AS) is becoming increasingly important with a better outcome after aortic valve replacement in asymptomatic severe AS patients and a poor outcome in moderate AS. We aimed to develop artificial intelligence-enabled electrocardiogram (AI-ECG) using a convolutional neural network to identify patients with moderate to severe AS. METHODS AND RESULTS: Between 1989 and 2019, 258 607 adults [mean age 63 ± 16.3 years; women 122 790 (48%)] with an echocardiography and an ECG performed within 180 days were identified from the Mayo Clinic database. Moderate to severe AS by echocardiography was present in 9723 (3.7%) patients. Artificial intelligence training was performed in 129 788 (50%), validation in 25 893 (10%), and testing in 102 926 (40%) randomly selected subjects. In the test group, the AI-ECG labelled 3833 (3.7%) patients as positive with the area under the curve (AUC) of 0.85. The sensitivity, specificity, and accuracy were 78%, 74%, and 74%, respectively. The sensitivity increased and the specificity decreased as age increased. Women had lower sensitivity but higher specificity compared with men at any age groups. The model performance increased when age and sex were added to the model (AUC 0.87), which further increased to 0.90 in patients without hypertension. Patients with false-positive AI-ECGs had twice the risk for developing moderate or severe AS in 15 years compared with true negative AI-ECGs (hazard ratio 2.18, 95% confidence interval 1.90-2.50). CONCLUSION: An AI-ECG can identify patients with moderate or severe AS and may serve as a powerful screening tool for AS in the community.

来源:Eur Heart J,查看原文。版权归原作者所有。

引用

  1. Cohen-Shelly M, Attia ZI, Friedman PA, et al. Electrocardiogram screening for aortic valve stenosis using artificial intelligence. Eur Heart J. 2021. PMID: 33748852. doi:10.1093/eurheartj/ehab153

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。