改良心房颤动患者心力衰竭的超声心动图诊断:指数搏动法研究
该研究基于RATE-AF随机试验,在160例房颤患者中比较指数搏动法与常规连续搏动平均法测量LVEF、GLS和E/e'的可重复性、耗时及效度。结果显示指数搏动法变异系数最低、可重复性更优、耗时更短,且不损害与利钠肽的相关性,有望改善房颤患者心衰的诊断与分类。
要点
- 指数搏动法测量LVEF、GLS和E/e'的变异系数低于连续5搏或10搏平均法。
- 指数搏动法操作时间更短,E/e'测量仅需35.4秒,且观察者内和观察者间可重复性均更优。
- 单次指数搏动不损害LVEF、GLS或E/e'与利钠肽水平的关联。
核心结论
- 在房颤患者中,与连续多搏平均法相比,指数搏动法可提高超声心动图测量的可重复性并节省时间,且不影响效度。
研究设计与样本
- 基于RATE-AF随机试验,采用标准化盲法经胸超声心动图方案,纳入160例房颤患者。
主要发现
- 指数搏动法LVEF的搏动内变异系数为32%,低于连续5搏的51%和10搏的53%。
- 指数搏动法GLS的搏动内变异系数为26%,低于连续5搏的43%和10搏的42%。
- 指数搏动法E/e'的搏动内变异系数为25%,低于连续5搏的41%和10搏的41%。
- 指数搏动法观察者内(n=50)和观察者间(n=18)可重复性均优于连续搏动法,且操作更快(p<0.001)。
- 测量E/e'耗时35.4秒(95%CI 33.1-37.8),短于5搏法的44.7秒(95%CI 41.8-47.5)和10搏法的98.1秒(95%CI 91.7-104.4)。
临床怎么用
- 房颤患者心衰的超声评估中,可采用指数搏动法替代连续多搏平均法以减少测量变异并提高效率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To improve the echocardiographic assessment of heart failure in patients with atrial fibrillation (AF) by comparing conventional averaging of consecutive beats with an index-beat approach, whereby measurements are taken after two cycles with similar R-R interval. METHODS: Transthoracic echocardiography was performed using a standardised and blinded protocol in patients enrolled in the RATE-AF (RAte control Therapy Evaluation in permanent Atrial Fibrillation) randomised trial. We compared reproducibility of the index-beat and conventional consecutive-beat methods to calculate left ventricular ejection fraction (LVEF), global longitudinal strain (GLS) and E/e' (mitral E wave max/average diastolic tissue Doppler velocity), and assessed intraoperator/interoperator variability, time efficiency and validity against natriuretic peptides. RESULTS: 160 patients were included, 46% of whom were women, with a median age of 75 years (IQR 69-82) and a median heart rate of 100 beats per minute (IQR 86-112). The index-beat had the lowest within-beat coefficient of variation for LVEF (32%, vs 51% for 5 consecutive beats and 53% for 10 consecutive beats), GLS (26%, vs 43% and 42%) and E/e' (25%, vs 41% and 41%). Intraoperator (n=50) and interoperator (n=18) reproducibility were both superior for index-beats and this method was quicker to perform (p<0.001): 35.4 s to measure E/e' (95% CI 33.1 to 37.8) compared with 44.7 s for 5-beat (95% CI 41.8 to 47.5) and 98.1 s for 10-beat (95% CI 91.7 to 104.4) analyses. Using a single index-beat did not compromise the association of LVEF, GLS or E/e' with natriuretic peptide levels. CONCLUSIONS: Compared with averaging of multiple beats in patients with AF, the index-beat approach improves reproducibility and saves time without a negative impact on validity, potentially improving the diagnosis and classification of heart failure in patients with AF.
引用
- Bunting KV, Gill SK, Sitch A, et al. Improving the diagnosis of heart failure in patients with atrial fibrillation. Heart. 2021. PMID: 33692093. doi:10.1136/heartjnl-2020-318557
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。