运动时外周静脉压变化与Fontan不良结局相关
结果显示,无负荷运动和峰值运动时的PVP较静息PVP与不良Fontan结局(包括心律失常、非计划入院、需利尿剂的心衰、再干预及复合终点)关联更强。结论提示运动PVP监测可用于Fontan患者风险分层。
要点
- 运动时PVP升高与Fontan不良结局增多相关。
- 无负荷和峰值PVP的关联强于静息PVP。
- PVP监测或有助于Fontan风险分层。
核心结论
- 无负荷运动和峰值运动时较高的PVP与不良Fontan结局患病率较高强烈相关。
主要发现
- 运动过程中PVP从静息13.6±3.5 mm Hg升至无负荷 cycling 16.5±3.9 mm Hg,峰值达23.0±5.5 mm Hg。
- 除再干预外,无负荷和峰值PVP与所有不良结局的关联强于静息PVP(复合终点:静息PVP OR 2.8,p=0.023;无负荷PVP OR 6.1,p=0.001;峰值PVP OR 4.0,p<0.001)。
关键数值与推荐
- ROC曲线分析确定截断值对复合结局具有高特异性:无负荷PVP ≥18 mm Hg特异性88%;峰值PVP ≥25 mm Hg特异性89%。
临床怎么用
- 心肺运动试验中微创PVP监测可作为Fontan患者风险分层的工具。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Elevated central venous pressure (CVP) plays an important role in the development of adverse Fontan outcomes. Peripheral venous pressure (PVP) has been validated as a surrogate for CVP in Fontan patients. We hypothesised that PVP in response to exercise will be associated with a greater prevalence of Fontan morbidity. METHODS: Adult Fontan patients had cardiopulmonary exercise testing (CPET) with PVP monitoring in the upper extremity between 2015 and 2018. PVP at rest, during unloaded cycling and at peak exercise was compared between those with and without adverse Fontan outcomes including arrhythmia, unscheduled hospital admissions, heart failure requiring diuretics, need for reintervention and a composite outcome of the above morbidities, heart transplantation and death. RESULTS: Forty-six patients with a mean age at CPET of 26.9±9.5 years. During exercise, PVP increased from 13.6±3.5 mm Hg at rest, to 16.5±3.9 mm Hg during unloaded cycling, to 23.0±5.5 mm Hg at peak exercise. Unloaded and peak PVP were more strongly associated than resting PVP with all adverse outcomes, except reintervention (composite outcome: resting PVP: OR 2.8, p=0.023; unloaded PVP: OR 6.1, p=0.001; peak PVP: OR 4.0, p<0.001). Cut-offs determined using ROC curve analysis had high specificity for the composite outcome (88% unloaded PVP ≥18 mm Hg; 89% peak PVP ≥25 mm Hg). CONCLUSION: Higher PVP at unloaded and peak exercise was strongly associated with a higher prevalence of adverse Fontan outcomes. Minimally invasive PVP monitoring during CPET may serve as a useful tool for risk stratifying individuals with a Fontan.
引用
- Colman K, Alsaied T, Lubert A, et al. Peripheral venous pressure changes during exercise are associated with adverse Fontan outcomes. Heart. 2021. PMID: 33127650. doi:10.1136/heartjnl-2020-317179
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。