人类室速折返环组成决定心动过速周期长度:快慢与不稳定性室速的特征分析
外环传导速度是唯一与周期长度相关的环组成部分,且慢传导区域提示峡部空间受限。
要点
- 室速折返环尺寸不能预测心动过速周期长度
- 外环传导速度是室速速率的主要决定因素
- 长而连续的心内电图提示峡部空间受限
核心结论
- 由于人类室速折返路径中传导速度存在广泛差异,折返环尺寸不能预测室速周期长度。
- 外环传导速度而非峡部是室速速率的主要决定因素。
- 快慢室速之间以及不稳定与稳定室速之间的折返环尺寸相似。
研究设计与样本
- 患者中男性占88%,年龄65岁(58-71岁),非缺血性占47%。
- 快室速定义为周期长度<333毫秒(频率>180次/分);不稳定室速定义为持续性发作时内在平均动脉压<60毫米汞柱伴血流动力学恶化。
主要发现
- 室速周期长度中位数为365毫秒(306-443毫秒),其中24个为快室速。
- 传导速度在入口(0.03-0.55米/秒)、共同通路(0.03-0.77米/秒)、出口(0.03-0.53米/秒)和外环(0.17-1.13米/秒)均呈现宽范围。
- 快与慢室速之间、不稳定与稳定室速之间,峡部和路径长度的中位尺寸无显著差异。
- 外环传导速度是唯一与周期长度相关的环组成部分,在缺血性心肌病(r=-0.5,P=0.006)和非缺血性心肌病(r=-0.45,P=0.028)中均相关。
- 最长舒张期电图持续时间与共同通路尺寸(长度:r=-0.46,P=0.001;宽度:r=-0.3,P=0.047)呈负相关,并预测单次射频消融快速终止室速(r=-0.41,P=0.023)。
临床怎么用
- 室速消融时不应仅根据折返环尺寸判断心动过速速率,应关注外环传导速度。
- 长而连续的心内电图可提示峡部空间受限,有助于预测射频消融能否快速终止室速。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Fast ventricular tachycardias (VTs) have historically been attributed to shorter path lengths with smaller reentrant circuit dimensions in animal models. The relationship between the dimensions of the reentrant VT circuit and tachycardia cycle length (TCL) has not been examined in humans. This study aimed to analyze the determinants of the rate of human VT with comparison of circuit dimensions and conduction velocity (CV) across a wide range of both stable and unstable VTs delineated by high-resolution mapping. METHODS: Fifty-four VTs with complete circuit delineation (>90% TCL) by high-resolution multielectrode mapping were analyzed in 49 patients (men, 88%; age, 65 years [58-71 years]; nonischemic, 47%). Fast VT was defined as TCL <333 milliseconds (rate >180 bpm). Unstable VT was defined by hemodynamic deterioration with an intrinsic mean arterial pressure <60 mm Hg during a sustained episode. RESULTS: The median TCL of VT was 365 milliseconds (306-443 milliseconds), and 24 fast VTs were characterized. A wide range of CVs was observed within the entrance (0.03-0.55 m/s), common pathway (0.03-0.77 m/s), exit (0.03-0.53 m/s), and outer loop (0.17-1.13 m/s). There were no significant differences in the median dimensions of the isthmus and path length between fast and slow VTs and between unstable and stable VTs. The outer loop CV was the only circuit component that correlated with TCL in both ischemic cardiomyopathy (r=-0.5, P=0.006) and nonischemic cardiomyopathy (r=-0.45, P=0.028). The duration of the longest diastolic electrogram was inversely correlated with the dimensions of common pathway (length: r=-0.46, P=0.001, width: r=-0.3, P=0.047) and predictive of rapid VT termination by a single radiofrequency application (r=-0.41, P=0.023). CONCLUSIONS: Because of a wide spectrum of CV observed within the reentrant path during human VT, the dimensions of the circuit were not predictive of VT cycle length. For the first time, we demonstrate that the CV of the outer loop, rather than isthmus, is the principal determinant of the rate of VT. The size of the circuit was similar between fast and slow VTs and between unstable and stable VTs. Long, continuous electrograms were indicative of spatially confined isthmus dimensions, confirmed by rapid termination of VT during radiofrequency delivery.
引用
- Nishimura T, Upadhyay GA, Aziz ZA, et al. Circuit Determinants of Ventricular Tachycardia Cycle Length: Characterization of Fast and Unstable Human Ventricular Tachycardia. Circulation. 2020. PMID: 33169628. doi:10.1161/CIRCULATIONAHA.120.050363
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。