文献速递心力衰竭与心肌病心律失常

左心室电激动延迟与右左心室起搏间距优化左心室起搏位点的应用与疗效

[Application and efficacy of the adjustment on left ventricular electrical delay and the distance between right and left ventricular pacing polar in optimizing the left ventricular pacing polar].
PubMed 文献 · Zhonghua Xin Xue Guan Bing Za Zhi · 2020-01-01

本研究纳入29例植入左心室四极电极行心脏再同步治疗(CRT)的心力衰竭患者,按避免膈神经刺激、合适阈值、避开心尖、最大左心室电激动延迟(LVED)及最大右左心室起搏间距(DRLV)的流程选择左心室起搏位点。术后6个月双心室起搏百分比均大于95%,QRS波时限、左心室收缩末容积、左心室射血分数、左心室舒张末内径、6分钟步行距离及NYHA分级均较术前明显改善(P均<0.001),CRT应答率97%、超声心动图应答率83%。

要点

  • 按最大LVED和DRLV优化左心室起搏位点,CRT应答率较高。
  • 66%患者应用了四极电极特异的M3或P4起搏位点,传统双极电极无法实现。
  • 术后6个月双心室起搏百分比均大于95%,心功能及超声指标显著改善。

核心结论

  • 左心室四极电极的LVED和DRLV可用于选择左心室起搏位点,以最大LVED及DRLV为依据选择起搏位点时CRT应答率较高。

研究设计与样本

  • 单中心研究,纳入2014年1月至2018年1月在北部战区总医院接受左心室四极电极CRT的心力衰竭患者29例,男性19例(66%),年龄(61.7±7.6)岁。
  • 扩张型心肌病17例(59%),缺血性心脏病12例(41%)。

主要发现

  • 所有患者均成功置入左心室四极电极至靶血管内,且4个起搏位点均在靶血管内;侧静脉15例(52%)、前静脉2例(7%)、后静脉11例(38%)、心大静脉侧分支1例(3%)。
  • 术后6个月双心室起搏百分比均大于95%。
  • 以最大LVED选择起搏位点19例(66%),以最大DRLV选择4例(14%);最终D1起搏5例(17%)、M2起搏5例(17%)、M3起搏7例(24%)、P4起搏12例(41%)。
  • 10例(34%)应用传统双极电极具备的起搏位点(D1、M2),19例(66%)应用四极电极特异的起搏位点(M3、P4),后者传统双极电极无法实现。
  • 术前QRS波时限、左心室收缩末容积、左心室射血分数、左心室舒张末内径、6分钟步行距离、NYHA分级分别为(171±24)ms、(231±79)ml、(28±5)%、(74±11)mm、(294±103)m、(3.2±1.0)级,术后6个月分别为(130±12)ms、(158±73)ml、(36±10)%、(66±12)mm、(371±86)m、(1.9±0.5)级,均较术前明显改善(P均<0.001)。

关键数值与推荐

  • 左心室起搏位点选择流程依次为:(1)避免膈神经刺激;(2)合适起搏阈值;(3)避开心尖部起搏;(4)选择最大LVED;(5)选择最大DRLV。

临床怎么用

  • 对植入左心室四极电极行CRT的心力衰竭患者,可按避免膈神经刺激、合适阈值、避开心尖、最大LVED及最大DRLV的流程优化左心室起搏位点。
  • 四极电极可使多数患者(66%)选用传统双极电极无法实现的M3或P4起搏位点。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To investigate the application and efficacy of left ventricular (LV) electrical delay (LVED) and the distance of right ventricular(RV) pacing polar to LV(DRLV) in optimizing LV pacing polar. Methods: Heart failure (HF) patients who implanted cardiac resynchronization therapy (CRT) device with a LV quadripolar lead from January 2014 to January 2018 at General Hospital of Northern Theater Command were enrolled in the study. Measurements of LVED and DRLV of each polar of the lead were performed in patients with HF who underwent CRT with LV quadripolar lead. The principle in turn for polar selecting used for clinical LV pacing was the pacing polar: (1)without phrenic nerve stimulation(PNS); (2)with appropriate capture threshold; (3)not located in apical; (4)with maximal LVED; (5)with maximal DRLV. The LV pacing polar was selected for CRT according to the procedure. The distribution of target veins implanted with LV quadripolar lead were calculated. The percentage of biventricular pacing at 6-month follow-up was recorded. The following indexes were compared before and 6-month after surgery, including QRS duration, LV end-systolic volume(LVESV), LV ejection fraction(LVEF), LV end-diastolic dimension(LVEDD), 6 minute walking distance(6MWD), New York Heart Association(NYHA) class. The efficacy and echocardiographic efficacy of CRT was evaluated. Results: There were twenty-nine HF patients enrolled. The mean age of enrolled patients was(61.7±7.6)years old, nineteen (66%)of them were male. There were seventeen(59%) patients diagnosed as dilated cardiomyopathy and twelve(41%) patients as ischemic cardiomyopathy. All patients were successfully implanted with LV quadripolar lead into target veins, and all four pacing sites were also in target veins. Target veins were located in lateral veins in 15 patients (52%), anterior veins in 2 patients (7%), posterior veins in 11 patients (38%), and lateral branches of great cardiac veins in 1 patient (3%). After 6-month of follow-up, the percentage of biventricular pacing was greater than 95%.There were nineteen(66%) patients optimized LV pacing polar by the largest LVED and four (14%) patients by the DRLV. Of the 29 patients, 5(17%) patients used D1 as the pacing polar, 5(17%) patients used M2 as the pacing polar, 7(24%) patients used M3 as the pacing polar, and 12(41%) patients used P4 as the pacing polar. The pacing polars (D1, M2) of traditional bipolar lead were used in 10(34%) patients, and the LV quadripolar lead specific pacing polars (M3, P4) were used in 19(66%) patients.Compared to a LV quadripolar lead, the LV pacing polar (M3, P4) selected in 19(66%) patients were not achievable with the traditional LV bipolar lead (D1, M2). Preoperative QRS duration, LVESV, LVEF, LVEDD, 6MWD and NYHA class were (171±24)ms, (231±79)ml, (28±5)%, (74±11)mm, (294±103)m, (3.2±1.0)class and the postoperative 6-month were (130±12)ms, (158±73)ml, (36±10)%, (66±12)mm, (371±86)m, (1.9±0.5)class. These indexes were significantly improved after 6 months operation(P<0.001). 97% and 83% patients were responders of CRT as assessed by 6-month efficacy and echocardiographic efficacy. Conclusion: The maximal LVED and DRLV can be used to select LV pacing polar with a high rate of CRT response rate. 目的: 探讨左心室电激动延迟程度(LVED)及右心室与左心室起搏位点的距离(DRLV)在优化左心室起搏位点中的应用及疗效。 方法: 选取2014年1月至2018年1月在北部战区总医院接受应用左心室四极电极进行心脏再同步治疗(CRT)的心力衰竭患者,测量其左心室4个起搏位点的LVED及DRLV。按如下流程优化选择左心室起搏位点:(1)避免膈神经刺激(PNS);(2)合适的起搏阈值;(3)避开心尖部起搏;(4)选择最大LVED;(5)选择最大DRLV。按流程选择左心室起搏位点进行CRT,统计左心室四极电极置入的靶血管分布情况。记录术后6个月随访时患者的双心室起搏百分比;比较患者术前及术后6个月的QRS波时限、左心室收缩末容积、左心室射血分数、左心室舒张末内径、6 min步行距离、纽约心脏病协会(NYHA)心功能分级,并统计CRT术后有应答及超声心动图检查有应答的患者比例。 结果: 入选29例心力衰竭患者,男性19例(66%),年龄(61.7±7.6)岁。扩张型心肌病17例(59%),缺血性心脏病12例(41%)。所有患者均成功置入左心室四极电极至靶血管内,且4个起搏位点亦均在靶血管内,侧静脉15例(52%),前静脉2例(7%),后静脉11例(38%),心大静脉侧分支1例(3%)。术后6个月双心室起搏百分比均大于95%。以最大的LVED及最大的DRLV作为依据选择左心室起搏位点的患者分别有19例(66%)和4例(14%)。最终29例患者中,有5例(17%)以D1作为起搏位点,5例(17%)以M2作为起搏位点,7例(24%)以M3作为起搏位点,12例(41%)以P4作为起搏位点。10例(34%)患者应用了传统双极电极具备的起搏位点(D1、M2),19例(66%)患者应用了左心室四极电极特异的起搏位点(M3、P4)。29例患者术前QRS波时限、左心室收缩末容积、左心室射血分数、左心室舒张末内径、6 min步行距离、NYHA分级分别为(171±24)ms、(231±79)ml、(28±5)%、(74±11)mm、(294±103)m、(3.2±1.0)级;术后6个月分别为(130±12)ms、(158±73)ml、(36±10)%、(66±12)mm、(371±86)m、(1.9±0.5)级,均较术前明显改善(P均<0.001)。CRT术后6个月应答率及超声心动图检查应答率分别为97%(28例)、83%(24例)。 结论: 左心室四极电极的4个LVED和DRLV可用来选择左心室起搏位点,且以最大LVED及DRLV作为依据选择起搏位点,CRT应答率较高。.

来源:Zhonghua Xin Xue Guan Bing Za Zhi,查看原文。版权归原作者所有。

引用

  1. Yan XL, Liang YC, Yu HB, et al. [Application and efficacy of the adjustment on left ventricular electrical delay and the distance between right and left ventricular pacing polar in optimizing the left ventricular pacing polar]. Zhonghua Xin Xue Guan Bing Za Zhi. 2020. PMID: 32847323. doi:10.3760/cma.j.cn112148-20200227-00132

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。