电解剖电压标测指导心内膜心肌活检的诊断价值
该研究纳入2010至2019年连续162例接受心内膜心肌活检(EMB)的患者,比较电解剖电压标测(EVM)与心脏磁共振(CMR)指导活检的诊断价值。EVM识别低电压区的灵敏度与CMR相似(74%对77%),两者联合灵敏度达95%,且EVM能发现CMR未识别的病变区域。EVM联合CMR对EMB的阳性预测值为89%。
要点
- EVM指导EMB安全可行,并发症率低,主要与血管入路相关。
- EVM识别心肌病理基质的灵敏度与CMR相似,联合应用灵敏度达95%。
- EVM可发现CMR未检测到的病变区域,联合阳性预测值89%。
核心结论
- EVM是指导靶向EMB的有前景工具,其识别心肌病理基质的灵敏度和特异度与CMR相似。
- EVM与CMR联合应用可提高诊断效能,阳性预测值达89%。
研究设计与样本
- 回顾性纳入2010至2019年连续162例接受EMB的患者。
- 在EVM和CMR识别的病理区域进行EMB,根据EMB结果评估EVM和CMR识别病理基质的灵敏度和特异度。
主要发现
- 术前CMR显示70%患者存在晚期钆增强,EVM识别61%患者存在低电压区。
- 取样部位为右室73%、左室19%、双室8%。
- EVM灵敏度74%、特异度70%;CMR灵敏度77%、特异度47%。
- 12例EMB证实心肌病的患者中,EVM识别出CMR未检测到的病理区域。
- EVM联合CMR的灵敏度高达95%,对EMB的阳性预测值为89%。
临床怎么用
- 对于需要EMB明确诊断的心肌病或心肌炎患者,可考虑EVM指导活检以提高诊断阳性率。
- EVM可与CMR联合使用,以互补识别病理区域,提高活检的准确性。
局限性
- 本研究为单中心回顾性队列,样本量有限。
- EVM特异度(70%)低于CMR(47%),可能存在假阳性区域。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Electroanatomic voltage mapping (EVM) is a promising modality for guiding endomyocardial biopsies (EMBs). However, few data support its feasibility and safety. We now report the largest cohort of patients undergoing EVM-guided EMBs to show its diagnostic yield and to compare it with a cardiac magnetic resonance (CMR)-guided approach. METHODS: We included 162 consecutive patients undergoing EMB at our institution from 2010 to 2019. EMB was performed in pathological areas identified at EVM and CMR. CMR and EVM sensitivity and specificity regarding the identification of pathological substrates of myocardium were evaluated according to EMB results. RESULTS: Preoperative CMR showed late gadolinium enhancement in 70% of the patients, whereas EVM identified areas of low voltage in 61%. Right (73%), left (19%), or both ventricles (8%) underwent sampling. EVM proved to have sensitivity similar to CMR (74% versus 77%), with specificity being 70% and 47%, respectively. In 12 patients with EMB-proven cardiomyopathy, EVM identified pathological areas that had been undetected at CMR evaluation. Sensitivity of pooled EVM and CMR was as high as 95%. EMB analysis allowed us to reach a new diagnosis, different from the suspected clinical diagnosis, in 39% of patients. The complications rate was low, mostly related to vascular access, with no patients requiring urgent management. CONCLUSIONS: EVM proved to be a promising tool for targeted EMB because of its sensitivity and specificity for identification of myocardial pathological substrates. EVM was demonstrated to have accuracy similar to CMR. EVM and CMR together conferred a positive predictive value of 89% on EMB.
引用
- Casella M, Dello Russo A, Bergonti M, et al. Diagnostic Yield of Electroanatomic Voltage Mapping in Guiding Endomyocardial Biopsies. Circulation. 2020. PMID: 32791857. doi:10.1161/CIRCULATIONAHA.120.046900
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。