文献速递瓣膜病与结构性心脏病血脂与心血管预防

经导管主动脉瓣植入通过减少剪切应力诱导的Piezo-1介导的单核细胞活化发挥抗炎治疗作用

Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation.
PubMed 文献 · Circulation · 2020-07-08

本研究探讨主动脉瓣狭窄中高剪切应力对单核细胞的促炎效应及TAVI后的变化。通过比较TAVI前后单核细胞活化状态,并结合微流控系统、功能实验及基因/药理干预,发现高剪切应力经Piezo-1介导钙内流和单核细胞黏附,TAVI可降低单核细胞活化、黏附、吞噬、oxLDL摄取及炎症标志物表达,提示TAVI具有抗炎获益。

要点

  • TAVI解除高剪切应力后,单核细胞Mac-1活化、黏附、吞噬及炎症标志物表达降低。
  • Piezo-1是高剪切应力激活单核细胞的主要机械感受器,为潜在药物靶点。
  • TAVI除改善血流动力学外,还具有抗炎治疗效应。

核心结论

  • 高剪切应力通过Piezo-1激活单核细胞多种功能,TAVI可减轻该炎症反应并展现抗炎治疗获益。

研究设计与样本

  • 研究比较TAVI前后(高剪切应力与低剪切应力)单核细胞活化状态,使用MAN-1单链抗体检测活化β2整合素Mac-1。
  • 通过单核细胞黏附、吞噬、oxLDL摄取和细胞因子表达等功能实验,结合微流控系统模拟TAVI前后剪切率。
  • 采用功能实验、Ca2+成像、siRNA基因沉默及药理激动剂/拮抗剂鉴定关键机械感受器,并对摘除的狭窄主动脉瓣进行单核细胞染色。

主要发现

  • TAVI解除高剪切应力后,单核细胞Mac-1活化、细胞黏附、吞噬、oxLDL摄取及单核细胞和血浆炎症标志物表达均降低。
  • 微流控及药理/遗传学研究显示,剪切应力依赖性钙内流和单核细胞黏附由机械敏感离子通道Piezo-1介导。
  • Piezo-1表达呈剪切应力依赖性,接受TAVI的患者中其表达下调。
  • 摘除的狭窄主动脉瓣叶主动脉侧可见单核细胞积聚。

临床怎么用

  • TAVI不仅解除主动脉瓣狭窄的血流动力学梗阻,还可能通过降低剪切应力减轻单核细胞介导的炎症。
  • Piezo-1作为高剪切应力激活单核细胞的主要机械感受器,为主动脉瓣狭窄相关炎症提供潜在药物靶点。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Aortic valve stenosis is an increasingly prevalent degenerative and inflammatory disease. Transcatheter aortic valve implantation (TAVI) has revolutionized its treatment, thereby avoiding its life-threatening/disabling consequences. Whether aortic valve stenosis is accelerated by inflammation and whether it is itself a cause of inflammation are unclear. We hypothesized that the large shear forces exerted on circulating cells, particularly on the largest circulating cells, monocytes, while passing through stenotic aortic valves result in proinflammatory effects that are resolved with TAVI. METHODS: TAVI provides a unique opportunity to compare the activation status of monocytes under high shear stress (before TAVI) and under low shear stress (after TAVI). The activation status of monocytes was determined with a single-chain antibody, MAN-1, which is specific for the activated β2-integrin Mac-1. Monocyte function was further characterized by the adhesion of myocytes to stimulated endothelial cells, phagocytic activity, uptake of oxidized low-density lipoprotein, and cytokine expression. In addition, we designed a microfluidic system to recapitulate the shear rate conditions before and after TAVI. We used this tool in combination with functional assays, Ca2+ imaging, siRNA gene silencing, and pharmacological agonists and antagonists to identify the key mechanoreceptor mediating the shear stress sensitivity of monocytes. Last, we stained for monocytes in explanted stenotic aortic human valves. RESULTS: The resolution of high shear stress through TAVI reduces Mac-1 activation, cellular adhesion, phagocytosis, oxidized low-density lipoprotein uptake, and expression of inflammatory markers in monocytes and plasma. Using microfluidics and pharmacological and genetic studies, we could recapitulate high shear stress effects on isolated human monocytes under highly controlled conditions, showing that shear stress-dependent calcium influx and monocyte adhesion are mediated by the mechanosensitive ion channel Piezo-1. We also demonstrate that the expression of this receptor is shear stress dependent and downregulated in patients receiving TAVI. Last, we show monocyte accumulation at the aortic side of leaflets of explanted aortic valves. CONCLUSIONS: We demonstrate that high shear stress, as present in patients with aortic valve stenosis, activates multiple monocyte functions, and we identify Piezo-1 as the mainly responsible mechanoreceptor, representing a potentially druggable target. We demonstrate an anti-inflammatory effect and therefore a novel therapeutic benefit of TAVI.

来源:Circulation,查看原文。版权归原作者所有。

引用

  1. Baratchi S, Zaldivia MTK, Wallert M, et al. Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation. Circulation. 2020. PMID: 32697107. doi:10.1161/CIRCULATIONAHA.120.045536

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。