跨瓣流量速率决定主动脉瓣面积在主动脉瓣狭窄中的预后价值
本研究基于1131例中重度主动脉瓣狭窄(AS)患者的纵向数据库,评估跨瓣流量速率对主动脉瓣面积(AVA)≤1.0 cm²预后价值的影响,并在939例外部队列中验证。结果显示,AVA≤1.0 cm²仅在流量速率高于中位数(>242 ml/s)时对死亡有显著预后价值(p=0.003),低于中位数(≤242 ml/s)时无预后价值(p=0.15);最佳流量速率截断值为210 ml/s。结论提示低流量下测得的AVA不是真正重度AS的良好诊断或预后标志物,应将流量速率评估纳入AS的临床诊断、分类和预后。
要点
- AVA≤1.0 cm²仅在流量速率>242 ml/s时对死亡有显著预后价值(p=0.003)。
- 流量速率≤242 ml/s时AVA≤1.0 cm²无预后价值(p=0.15),验证队列一致。
- 最佳流量速率截断值为210 ml/s,低流量下AVA不宜作为真正重度AS的标志。
核心结论
- 跨瓣流量速率决定AVA在AS中的预后价值,低流量下测得的AVA≤1.0 cm²不是良好的预后或诊断标志物。
研究设计与样本
- 纵向数据库纳入1131例中重度AS且临床随访完整的患者,并在939例独立外部队列中验证。
- 评估流量速率(每搏输出量与射血时间之比)对AVA≤1.0 cm²预测死亡时间的影响,并做多变量校正和敏感性分析。
主要发现
- 流量速率对AVA的预后价值有显著影响:AVA≤1.0 cm²在流量速率≤242 ml/s时对死亡无预后价值(p=0.15)。
- AVA≤1.0 cm²在流量速率>242 ml/s时对死亡有高度预后价值(p=0.003),且不受多变量校正影响。
- 验证队列中,流量速率低于中位数时AVA≤1.0 cm²同样不是死亡的独立预测因子。
- 预后阈值的最佳流量速率截断值为210 ml/s。
关键数值与推荐
- AVA≤1.0 cm²为重度AS的定义特征,但低流量速率下可被低估。
- 流量速率中位数为242 ml/s,最佳预后截断值为210 ml/s。
临床怎么用
- 临床诊断、分类和预后评估AS时应纳入跨瓣流量速率评估。
- 低流量速率下测得的AVA≤1.0 cm²不应单独作为真正重度AS的诊断依据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Aortic valve area (AVA) ≤1.0 cm2 is a defining characteristic of severe aortic stenosis (AS). AVA can be underestimated at low transvalvular flow rate. Yet, the impact of flow rate on prognostic value of AVA ≤1.0 cm2 is unknown and is not incorporated into AS assessment. OBJECTIVES: This study aimed to evaluate the effect of flow rate on prognostic value of AVA in AS. METHODS: In total, 1,131 patients with moderate or severe AS and complete clinical follow-up were included as part of a longitudinal database. The effect of flow rate (ratio of stroke volume to ejection time) on prognostic value of AVA ≤1.0 cm2 for time to death was evaluated, adjusting for confounders. Sensitivity analysis was performed to identify the optimal cutoff for prognostic threshold of AVA. The findings were validated in a separate external longitudinal cohort of 939 patients. RESULTS: Flow rate had a significant effect on prognostic value of AVA. AVA ≤1.0 cm2 was not prognostic for mortality (p = 0.15) if AVA was measured at flow rates below median (≤242 ml/s). In contrast, AVA ≤1.0 cm2 was highly prognostic for mortality (p = 0.003) if AVA was measured at flow rates above median (>242 ml/s). Findings were irrespective of multivariable adjustment for age, sex, and surgical/transcatheter aortic valve replacement (as time-dependent covariates); comorbidities; medications; and echocardiographic features. AVA ≤1.0 cm2 was also not an independent predictor of mortality below median flow rate in the validation cohort. The optimal flow rate cutoff for prognostic threshold was 210 ml/s. CONCLUSIONS: Transvalvular flow rate determines prognostic value of AVA in AS. AVA measured at low flow rate is not a good prognostic marker and therefore not a good diagnostic marker for truly severe AS. Flow rate assessment should be incorporated into clinical diagnosis, classification, and prognosis of AS.