文献速递心力衰竭与心肌病心律失常

基于力-频率关系的个体化频率应答编程改善心衰患者运动耐量:一项II期研究

Personalized Rate-Response Programming Improves Exercise Tolerance After 6 Months in People With Cardiac Implantable Electronic Devices and Heart Failure: A Phase II Study.
PubMed 文献 · Circulation · 2020-04-17

本研究为单中心、双盲、随机、平行组II期试验,纳入83例稳定症状性HFrEF且植入心脏电子设备的患者,比较基于个体无创FFR数据定制频率应答编程与常规年龄指导编程。6个月时FFR指导组踏车步行时间平均增加75.4秒,常规组增加3.1秒(组间P=0.044),且FFR指导组峰值平均心率更低,对LV结构和功能无不良影响。

要点

  • 基于无创FFR定制频率应答编程可改善HFrEF患者6个月运动耐量。
  • FFR指导组峰值心率更低但运动时间增加更显著。
  • 常规年龄指导编程与LV射血分数下降相关,FFR指导无此不良影响。

核心结论

  • 基于可重复无创方法测定的FFR指导频率应答编程,似乎可改善HFrEF合并心脏电子设备患者的运动时间并限制LV功能变化。

研究设计与样本

  • 单中心、双盲、随机、平行组II期试验,纳入83例稳定症状性HFrEF且接受指南导向药物治疗并植入CRT或ICD的患者,1:1随机至FFR指导或常规年龄指导频率应答编程。

主要发现

  • 6个月时踏车步行时间平均变化:FFR指导组75.4秒(95%CI 23.4至127.5),常规组3.1秒(95%CI -44.1至50.3),组间P=0.044。
  • FFR指导组峰值平均心率98.6±19.4次/分,低于常规组的112.0±20.3次/分。
  • FFR指导组对LV结构和功能无不良影响,常规组与LV射血分数下降相关。

临床怎么用

  • 对植入心脏电子设备的HFrEF患者,可考虑基于个体无创FFR数据定制频率应答编程以改善运动耐量。

局限性

  • 本研究为单中心II期试验,样本量83例,需多中心及更长随访临床结局验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Heart failure with reduced ejection fraction (HFrEF) is characterized by blunting of the positive relationship between heart rate and left ventricular (LV) contractility known as the force-frequency relationship (FFR). We have previously described that tailoring the rate-response programming of cardiac implantable electronic devices in patients with HFrEF on the basis of individual noninvasive FFR data acutely improves exercise capacity. We aimed to examine whether using FFR data to tailor heart rate response in patients with HFrEF with cardiac implantable electronic devices favorably influences exercise capacity and LV function 6 months later. METHODS: We conducted a single-center, double-blind, randomized, parallel-group trial in patients with stable symptomatic HFrEF taking optimal guideline-directed medical therapy and with a cardiac implantable electronic device (cardiac resynchronization therapy or implantable cardioverter-defibrillator). Participants were randomized on a 1:1 basis between tailored rate-response programming on the basis of individual FFR data and conventional age-guided rate-response programming. The primary outcome measure was change in walk time on a treadmill walk test. Secondary outcomes included changes in LV systolic function, peak oxygen consumption, and quality of life. RESULTS: We randomized 83 patients with a mean±SD age 74.6±8.7 years and LV ejection fraction 35.2±10.5. Mean change in exercise time at 6 months was 75.4 (95% CI, 23.4 to 127.5) seconds for FFR-guided rate-adaptive pacing and 3.1 (95% CI, -44.1 to 50.3) seconds for conventional settings (analysis of covariance; P=0.044 between groups) despite lower peak mean±SD heart rates (98.6±19.4 versus 112.0±20.3 beats per minute). FFR-guided heart rate settings had no adverse effect on LV structure or function, whereas conventional settings were associated with a reduction in LV ejection fraction. CONCLUSIONS: In this phase II study, FFR-guided rate-response programming determined using a reproducible, noninvasive method appears to improve exercise time and limit changes to LV function in people with HFrEF and cardiac implantable electronic devices. Work is ongoing to confirm our findings in a multicenter setting and on longer-term clinical outcomes. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02964650.