文献速递冠心病

ESC 0/1小时心肌梗死诊断算法的安全性与有效性:系统综述与荟萃分析

Safety and efficacy of the European Society of Cardiology 0/1-hour algorithm for diagnosis of myocardial infarction: systematic review and meta-analysis.
PubMed 文献 · Heart · 2020-04-03

基于hs-cTnT(Roche)、hs-cTnI(Abbott)和hs-cTnI(Siemens)的算法汇总敏感性分别为98.4%、98.1%和98.7%;排除组30天和1年死亡率分别为0.1%和0.8%。结论认为该算法诊断准确性高,但若追求1%的心肌梗死漏诊率,其安全性可能不足。

要点

  • ESC 0/1小时算法基于hs-cTnT(Roche)和hs-cTnI(Siemens)的汇总特异性分别为91.2%和95.9%。
  • 排除组30天死亡率为0.1%,1年死亡率为0.8%。
  • 观察区30天死亡率为0.7%,1年死亡率升至8.1%,与确诊组相当。

核心结论

  • ESC 0/1小时算法具有高诊断准确性,但若要求心肌梗死漏诊率低于1%,其安全性可能不足。

研究设计与样本

  • 系统综述与荟萃分析,检索PubMed、Embase、Scopus、Web of Science和Cochrane Central Register of Controlled Trials于2008年1月1日至2019年5月31日发表的相关研究。

主要发现

  • 基于hs-cTnT(Roche)、hs-cTnI(Abbott)和hs-cTnI(Siemens)的算法汇总敏感性分别为98.4%(95% CI=95.1%至99.5%)、98.1%(95% CI=94.6%至99.3%)和98.7%(95% CI=97.3%至99.3%)。
  • 基于hs-cTnT(Roche)和hs-cTnI(Siemens)的算法汇总特异性分别为91.2%(95% CI=86.0%至94.6%)和95.9%(95% CI=94.1%至97.2%)。
  • 排除组30天和1年汇总死亡率分别为0.1%(95% CI=0.0%至0.4%)和0.8%(95% CI=0.5%至1.2%)。
  • 观察区30天汇总死亡率为0.7%(95% CI=0.3%至1.2%),1年升至8.1%(95% CI=6.1%至10.4%),与确诊组死亡率相当。

临床怎么用

  • 临床使用ESC 0/1小时算法时需注意其诊断准确性虽高,但可能无法满足1%心肌梗死漏诊率的安全性要求,应结合临床评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The European Society of Cardiology (ESC) 0/1 hour algorithm has been primarily validated in Europe, America and Australasia with less knowledge of its performance outside of these settings. We aim to evaluate the performance of the ESC 0/1 hour algorithm across different contexts. METHODS: We searched PubMed, Embase, Scopus, Web of Science and the Cochrane Central Register of Controlled Trials for relevant studies published between 1 January 2008 and 31 May 2019. The primary outcome was index myocardial infarction and the secondary outcome was major adverse cardiac event or mortality. A bivariate random-effects meta-analysis was used to derive the pooled estimate of each outcome. RESULTS: A total of 11 014 patients from 10 cohorts were analysed for the primary outcome. The algorithm based on high-sensitivity cardiac troponin (hs-cTn)T (Roche), hs-cTnI (Abbott) and hs-cTnI (Siemens) had pooled sensitivity of 98.4% (95% CI=95.1% to 99.5%), 98.1% (95% CI=94.6% to 99.3%) and 98.7% (95% CI=97.3% to 99.3%), respectively. The algorithm based on hs-cTnT (Roche) and hs-cTnI (Siemens) had pooled specificity of 91.2% (95% CI=86.0% to 94.6%) and 95.9% (95% CI=94.1% to 97.2%), respectively. Among patients in the rule-out category, the pooled mortality rate at 30 days and at 1 year was 0.1% (95% CI=0.0% to 0.4%) and 0.8% (95% CI=0.5% to 1.2%), respectively. Among patients in the observation zone, the pooled mortality rate was 0.7% (95% CI=0.3% to 1.2%) at 30 days but increased to 8.1% (95% CI=6.1% to 10.4%) at 1 year, comparable to the mortality rate in the rule-in group. CONCLUSION: The ESC 0/1 hour algorithm has high diagnostic accuracy but may not be sufficiently safe if the 1% miss-rate for myocardial infarction is desired. PROSPERO REGISTRATION NUMBER: CRD42019142280.

来源:Heart,查看原文。版权归原作者所有。

引用

  1. Chiang CH, Chiang CH, Lee GH, et al. Safety and efficacy of the European Society of Cardiology 0/1-hour algorithm for diagnosis of myocardial infarction: systematic review and meta-analysis. Heart. 2020. PMID: 32245882. doi:10.1136/heartjnl-2019-316343

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。