文献速递心律失常

窦律下波前不连续引导的室速靶向消融:一种新的功能性基质标测策略

Targeted Ablation of Ventricular Tachycardia Guided by Wavefront Discontinuities During Sinus Rhythm: A New Functional Substrate Mapping Strategy.
PubMed 文献 · Circulation · 2019-09-19

95%的DZ与成功终止位点共定位,中位射频时间29分钟,随访12±10个月无室速复发率70%,总生存率87%。

要点

  • 窦律下等时图识别DZ可指导室速靶向消融
  • DZ与成功终止位点共定位率达95%
  • 靶向DZ消融射频时间短且复发率可控

核心结论

  • 窦律下高密度标测显示的功能性基质可识别室速折返巢,指导靶向消融,无需广泛射频。

主要发现

  • 窦律下高密度标测识别平均2±1个DZ,95%与室速成功终止位点共定位。
  • 靶向DZ消融中位射频时间29分钟,占低电压区18%。
  • 随访12±10个月,无室速复发率70%(缺血性心肌病80%,非缺血性63%),总生存率87%。

关键数值与推荐

  • DZ定义为1cm半径内超过3条等时线。
  • 优先消融激动较晚且等时线最密集的区域。

临床怎么用

  • 窦律下构建等时图识别DZ,可指导室速靶向消融,减少射频时间。
  • DZ共定位成功终止位点,提示其作为折返巢的机制价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Accurate and expedited identification of scar regions most prone to reentry is needed to guide ventricular tachycardia (VT) ablation. We aimed to prospectively assess outcomes of VT ablation guided primarily by the targeting of deceleration zones (DZ) identified by propagational analysis of ventricular activation during sinus rhythm. METHODS: Patients with scar-related VT were prospectively enrolled in the University of Chicago VT Ablation Registry between 2016 and 2018. Isochronal late activation maps annotated to the latest local electrogram deflection were created with high-density multielectrode mapping catheters. Targeted ablation of DZ (>3 isochrones within 1cm radius) was performed, prioritizing later activated regions with maximal isochronal crowding. When possible, activation mapping of VT was performed, and successful ablation sites were compared with DZ locations for mechanistic correlation. Patients were prospectively followed for VT recurrence and mortality. RESULTS: One hundred twenty patients (median age 65 years [59-71], 15% female, 50% nonischemic, median ejection fraction 31%) underwent 144 ablation procedures for scar-related VT. 57% of patients had previous ablation and epicardial access was employed in 59% of cases. High-density mapping during baseline rhythm was performed (2518 points [1615-3752] endocardial, 5049±2580 points epicardial) and identified an average of 2±1 DZ, which colocalized to successful termination sites in 95% of cases. The median total radiofrequency application duration was 29 min (21-38 min) to target DZ, representing ablation of 18% of the low-voltage area. At 12±10 months, 70% freedom from VT recurrence (80% in ischemic cardiomyopathy and 63% in nonischemic cardiomyopathy) was achieved. The overall survival rate was 87%. CONCLUSIONS: A novel voltage-independent high-density mapping display can identify the functional substrate for VT during sinus rhythm and guide targeted ablation, obviating the need for extensive radiofrequency delivery. Regions with isochronal crowding during the baseline rhythm were predictive of VT termination sites, providing mechanistic evidence that deceleration zones are highly arrhythmogenic, functioning as niduses for reentry.

来源:Circulation,查看原文。版权归原作者所有。

引用

  1. Aziz Z, Shatz D, Raiman M, et al. Targeted Ablation of Ventricular Tachycardia Guided by Wavefront Discontinuities During Sinus Rhythm: A New Functional Substrate Mapping Strategy. Circulation. 2019. PMID: 31533463. doi:10.1161/CIRCULATIONAHA.119.042423

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。