射血分数降低心衰一级预防ICD与死亡率关联的瑞典心衰登记倾向评分匹配分析
本研究基于瑞典心衰登记,纳入符合ESC一级预防ICD指征的射血分数降低心衰患者,采用1:1倾向评分匹配分析ICD使用与1年和5年全因及心血管死亡的关系。
要点
- 当代HFrEF人群中一级预防ICD使用率仅10%,存在明显未充分利用
- 倾向评分匹配后ICD使用与1年及5年全因死亡风险降低相关
- 缺血与非缺血、性别、年龄、CRT等各亚组结果一致
核心结论
- 在当代HFrEF人群中一级预防ICD使用不足,但与短期和长期全因死亡率降低相关,且各亚组一致。
研究设计与样本
- 基于瑞典心衰登记的前瞻性倾向评分匹配分析,纳入符合ESC一级预防ICD指征的HFrEF患者。
主要发现
- ICD使用与1年全因死亡风险降低相关(HR 0.73,95%CI 0.60-0.90)。
- ICD使用与5年全因死亡风险降低相关(HR 0.88,95%CI 0.78-0.99)。
- 各预设亚组(缺血与非缺血、男女、<75与≥75岁、登记入组早晚、是否CRT)结果一致。
关键数值与推荐
- 合格患者需符合ESC一级预防ICD指征。
临床怎么用
- 应加强HFrEF患者一级预防ICD的临床实施,评估符合ESC指征者是否植入。
局限性
- 为观察性登记分析,即使经倾向评分匹配仍可能存在残余混杂。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Most randomized trials on implantable cardioverter-defibrillator (ICD) use for primary prevention of sudden cardiac death in heart failure with reduced ejection fraction enrolled patients >20 years ago. We investigated the association between ICD use and all-cause mortality in a contemporary heart failure with reduced ejection fraction cohort and examined relevant subgroups. METHODS: Patients from the Swedish Heart Failure Registry fulfilling the European Society of Cardiology criteria for primary-prevention ICD were included. The association between ICD use and 1-year and 5-year all-cause and cardiovascular (CV) mortality was assessed by Cox regression models in a 1:1 propensity score-matched cohort and in prespecified subgroups. RESULTS: Of 16 702 eligible patients, only 1599 (10%) had an ICD. After matching, 1305 ICD recipients were compared with 1305 nonrecipients. ICD use was associated with a reduction in all-cause mortality risk within 1 year (hazard ratio, 0.73 [95% CI, 0.60-0.90]) and 5 years (hazard ratio, 0.88 [95% CI, 0.78-0.99]). Results were consistent in all subgroups including patients with versus without ischemic heart disease, men versus women, those aged <75 versus ≥75 years, those with earlier versus later enrollment in the Swedish heart failure registry, and patients with versus without cardiac resynchronization therapy. CONCLUSIONS: In a contemporary heart failure with reduced ejection fraction population, ICD for primary prevention was underused, although it was associated with reduced short- and long-term all-cause mortality. This association was consistent across all the investigated subgroups. These results call for better implementation of ICD therapy.
引用
- Schrage B, Uijl A, Benson L, et al. Association Between Use of Primary-Prevention Implantable Cardioverter-Defibrillators and Mortality in Patients With Heart Failure: A Prospective Propensity Score-Matched Analysis From the Swedish Heart Failure Registry. Circulation. 2019. PMID: 31476893. doi:10.1161/CIRCULATIONAHA.119.043012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。