RAPID-TnT多中心随机试验在疑似急性冠脉综合征急诊患者中比较0/1小时高敏肌钙蛋白T方案与0/3小时盲法方案,30天全因死亡和心肌梗死非劣效成立(1.0% vs 1.0%,非劣效P=0.006),0/1小时组急诊出院率更高、留观时间更短且功能检查更少,但观察到心肌损伤增加。

要点

  • 0/1小时hs-cTnT方案30天死亡或心肌梗死非劣效于0/3小时标准方案。
  • 0/1小时组急诊出院率45.1%高于标准组32.3%,中位留观时间4.6小时短于5.6小时。
  • 0/1小时方案心肌损伤检出增加,需优化新发肌钙蛋白T升高患者的管理。

核心结论

  • 在疑似急性冠脉综合征急诊患者中,0/1小时hs-cTnT方案在30天全因死亡和心肌梗死方面非劣效于0/3小时盲法hs-cTnT标准方案,且可更快速出院。

研究设计与样本

  • 最终0/1小时hs-cTnT组1646例、0/3小时标准盲法hs-cTnT组1642例,随访30天;中位年龄59(49-70)岁,47%为女性。

主要发现

  • 0/1小时组急诊出院率45.1%高于标准组32.3%(P<0.001),中位急诊留观时间4.6(IQR 3.4-6.4)小时短于标准组5.6(IQR 4.0-7.1)小时(P<0.001)。
  • 0/1小时组接受功能性心脏检查的比例7.5%低于标准组11.0%(P<0.001)。
  • 30天主要终点0/1小时组17/1646(1.0%)对标准组16/1642(1.0%),发生率比1.06(95%CI 0.53-2.11),非劣效P=0.006,优效性P=0.867。
  • 0/1小时方案观察到心肌损伤增加。
  • 急诊出院患者中,0/1小时方案对30天死亡或心肌梗死的阴性预测值为99.6%(95%CI 99.0-99.9%)。

关键数值与推荐

  • 0/1小时hs-cTnT方案报告至检测下限(<5 ng/L),标准组为0/3小时盲法hs-cTnT报告至≤29 ng/L。
  • 非劣效界值为绝对界值0.5%,由泊松回归确定。

临床怎么用

  • 在急诊疑似急性冠脉综合征评估中可采用0/1小时hs-cTnT方案以加快低危患者出院并缩短留观时间。
  • 对新发肌钙蛋白T升高的患者需发展更优管理策略以改善短期结局。

局限性

  • 原文未报告局限性内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: High-sensitivity troponin assays promise earlier discrimination of myocardial infarction. Yet, the benefits and harms of this improved discriminatory performance when incorporated within rapid testing protocols, with respect to subsequent testing and clinical events, has not been evaluated in an in-practice patient-level randomized study. This multicenter study evaluated the noninferiority of a 0/1-hour high-sensitivity cardiac troponin T (hs-cTnT) protocol in comparison with a 0/3-hour masked hs-cTnT protocol in patients with suspected acute coronary syndrome presenting to the emergency department (ED). METHODS: Patients were randomly assigned to either a 0/1-hour hs-cTnT protocol (reported to the limit of detection [<5 ng/L]) or masked hs-cTnT reported to ≤29 ng/L evaluated at 0/3-hours (standard arm). The 30-day primary end point was all-cause death and myocardial infarction. Noninferiority was defined as an absolute margin of 0.5% determined by Poisson regression. RESULTS: In total, 3378 participants with an emergency presentation were randomly assigned between August 2015 and April 2019. Ninety participants were deemed ineligible or withdrew consent. The remaining participants received care guided either by the 0/1-hour hs-cTnT protocol (n=1646) or the 0/3-hour standard masked hs-cTnT protocol (n=1642) and were followed for 30 days. Median age was 59 (49-70) years, and 47% were female. Participants in the 0/1-hour arm were more likely to be discharged from the ED (0/1-hour arm: 45.1% versus standard arm: 32.3%, P<0.001) and median ED length of stay was shorter (0/1-hour arm: 4.6 [interquartile range, 3.4-6.4] hours versus standard arm: 5.6 (interquartile range, 4.0-7.1) hours, P<0.001). Those randomly assigned to the 0/1-hour protocol were less likely to undergo functional cardiac testing (0/1-hour arm: 7.5% versus standard arm: 11.0%, P<0.001). The 0/1-hour hs-cTnT protocol was not inferior to standard care (0/1-hour arm: 17/1646 [1.0%] versus 16/1642 [1.0%]; incidence rate ratio, 1.06 [ 0.53-2.11], noninferiority P value=0.006, superiority P value=0.867), although an increase in myocardial injury was observed. Among patients discharged from ED, the 0/1-hour protocol had a negative predictive value of 99.6% (95% CI, 99.0-99.9%) for 30-day death or myocardial infarction. CONCLUSIONS: This in-practice evaluation of a 0/1-hour hs-cTnT protocol embedded in ED care enabled more rapid discharge of patients with suspected acute coronary syndrome. Improving short-term outcomes among patients with newly recognized troponin T elevation will require an evolution in management strategies for these patients. CLINICAL TRIAL REGISTRATION: URL: https://www.anzctr.org.au. Unique identifier: ACTRN12615001379505.

来源:Circulation,查看原文。版权归原作者所有。

引用

  1. Chew DP, Lambrakis K, Blyth A, et al. A Randomized Trial of a 1-Hour Troponin T Protocol in Suspected Acute Coronary Syndromes: The Rapid Assessment of Possible Acute Coronary Syndrome in the Emergency Department With High-Sensitivity Troponin T Study (RAPID-TnT). Circulation. 2019. PMID: 31478763. doi:10.1161/CIRCULATIONAHA.119.042891