房颤患者左心耳电隔离后的卒中风险
该研究纳入1854例连续接受左心耳电隔离(LAAEI)后6个月经食道超声(TEE)评估左心耳(LAA)功能的房颤患者。结果显示,LAA功能正常者未发生卒中;LAA收缩功能异常者中,持续口服抗凝(OAC)者卒中/短暂性脑缺血发作(TIA)发生率为1.7%,而未抗凝者为16.7%(p<0.001)。LAAEI与显著卒中风险相关,优化不间断OAC或左心耳封堵(LAAO)装置可有效降低该风险。
要点
- LAAEI后6个月TEE显示LAA功能正常者未发生卒中。
- LAA功能异常且未抗凝者卒中/TIA风险显著高于持续抗凝者。
- LAAO装置植入后停用OAC的患者未发生血栓栓塞事件。
核心结论
- LAAEI与显著卒中风险相关,优化不间断OAC或LAAO装置可有效降低该风险。
研究设计与样本
- 研究纳入1854例连续接受LAAEI后6个月在窦性心律下经TEE评估LAA功能的患者。
主要发现
- 6个月TEE显示336例(18%)LAA流速、收缩力及A波 preserved,其余1518例参数异常。
- LAA功能正常者(336例)停用OAC,长期随访未发生卒中事件。
- LAA功能异常者中,持续OAC者(1086例)卒中/TIA发生18例(1.7%),停用OAC者(432例)血栓栓塞事件72例(16.7%),p<0.001。
- 90例卒中患者中84例接受了LAAO装置;装置植入中位12.4个月(IQR 9.8-15.3)时,2例(2.4%)因高卒中风险或个人偏好仍用OAC,81例停用OAC后无血栓栓塞事件。
临床怎么用
- LAAEI术后应通过TEE评估LAA功能,功能异常者需持续OAC或考虑LAAO装置以降低卒中风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Loss of contractility leading to stasis of blood flow following left atrial appendage electrical isolation (LAAEI) could lead to thrombus formation. OBJECTIVES: This study evaluated the incidence of thromboembolic events (TE) in post-LAAEI cases "on" and "off" oral anticoagulation (OAC). METHODS: A total of 1,854 consecutive post-LAAEI patients with follow-up transesophageal echocardiography (TEE) performed in sinus rhythm at 6 months to assess left atrial appendage (LAA) function were included in this analysis. RESULTS: The TEE at 6 months revealed preserved LAA velocity, contractility, and consistent A waves in 336 (18%) and abnormal parameters in the remaining 1,518 patients. In the post-ablation period, all 336 patients with preserved LAA function were off OAC. At long-term follow-up, patients with normal LAA function did not experience any stroke events. Of the 1,518 patients with abnormal LAA contractility, 1,086 remained on OAC, and the incidence of stroke/transient ischemic attack (TIA) in this population was 18 of 1,086 (1.7%), whereas the number of TE events in the off-OAC patients (n = 432) was 72 (16.7%); p < 0.001. Of the 90 patients with stroke, 84 received left atrial appendage occlusion (LAAO) devices. At median 12.4 months (interquartile range: 9.8 to 15.3 months) of device implantation, 2 (2.4%) patients were on OAC because of high stroke risk or personal preference, whereas 81 patients discontinued OAC after LAAO device implantation without any TE events. CONCLUSIONS: LAAEI is associated with a significant risk of stroke that can be effectively reduced by optimal uninterrupted OAC or LAAO devices.
引用
- Di Biase L, Mohanty S, Trivedi C, et al. Stroke Risk in Patients With Atrial Fibrillation Undergoing Electrical Isolation of the Left Atrial Appendage. J Am Coll Cardiol. 2019. PMID: 31439209. doi:10.1016/j.jacc.2019.06.045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。