文献速递心力衰竭与心肌病心律失常

肥厚型心肌病心肌排列紊乱与室性心律失常的DT-CMR研究

Identification of Myocardial Disarray in Patients With Hypertrophic Cardiomyopathy and Ventricular Arrhythmias.
PubMed 文献 · J Am Coll Cardiol · 2019-01-01

本研究用扩散张量心脏磁共振(DT-CMR)评估肥厚型心肌病(HCM)患者舒张期分数各向异性(FA),发现HCM患者FA较健康对照降低,且肥厚节段FA降低与室性心律失常相关,校正纤维化指标后仍显著。提示FA可能反映心肌排列紊乱并作为室性心律失常的独立风险标志。

要点

  • HCM患者舒张期FA较对照降低,提示心肌排列紊乱。
  • 肥厚节段FA降低与室性心律失常独立相关。
  • FA降低0.05,室性心律失常风险增加2.5倍。

核心结论

  • HCM患者舒张期FA降低,与室性心律失常相关,校正纤维化后仍显著,可能反映心肌排列紊乱。

研究设计与样本

  • 研究纳入50例HCM患者(47±15岁,77%男性)和30例健康对照(46±16岁,70%男性),均行3-T DT-CMR舒张期、电影、LGE和ECV成像。

主要发现

  • HCM患者舒张期FA较对照降低(0.49±0.05 vs. 0.52±0.03;p=0.0005)。
  • 对照存在中层高FA环,HCM中该环被低FA破坏。
  • LGE和ECV是FA的显著预测因素,但校正后HCM FA仍降低(p=0.028)。
  • 合并室性心律失常的HCM患者肥厚节段FA更低(0.41±0.03 vs. 0.46±0.06;p=0.007)。
  • FA降低0.05,室性心律失常风险增加2.5倍(95%CI 1.2-5.3;p=0.015),校正LGE、ECV和壁厚后仍显著(p=0.036)。

临床怎么用

  • DT-CMR测量的舒张期FA可作为HCM心肌排列紊乱的无创影像标志物。
  • FA降低可能提示室性心律失常风险增加,或可作为独立风险因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Myocardial disarray is a likely focus for fatal arrhythmia in hypertrophic cardiomyopathy (HCM). This microstructural abnormality can be inferred by mapping the preferential diffusion of water along cardiac muscle fibers using diffusion tensor cardiac magnetic resonance (DT-CMR) imaging. Fractional anisotropy (FA) quantifies directionality of diffusion in 3 dimensions. The authors hypothesized that FA would be reduced in HCM due to disarray and fibrosis that may represent the anatomic substrate for ventricular arrhythmia. OBJECTIVES: This study sought to assess FA as a noninvasive in vivo biomarker of HCM myoarchitecture and its association with ventricular arrhythmia. METHODS: A total of 50 HCM patients (47 ± 15 years of age, 77% male) and 30 healthy control subjects (46 ± 16 years of age, 70% male) underwent DT-CMR in diastole, cine, late gadolinium enhancement (LGE), and extracellular volume (ECV) imaging at 3-T. RESULTS: Diastolic FA was reduced in HCM compared with control subjects (0.49 ± 0.05 vs. 0.52 ± 0.03; p = 0.0005). Control subjects had a mid-wall ring of high FA. In HCM, this ring was disrupted by reduced FA, consistent with published histology demonstrating that disarray and fibrosis invade circumferentially aligned mid-wall myocytes. LGE and ECV were significant predictors of FA, in line with fibrosis contributing to low FA. Yet FA adjusted for LGE and ECV remained reduced in HCM (p = 0.028). FA in the hypertrophied segment was reduced in HCM patients with ventricular arrhythmia compared to patients without (n = 15; 0.41 ± 0.03 vs. 0.46 ± 0.06; p = 0.007). A decrease in FA of 0.05 increased odds of ventricular arrhythmia by 2.5 (95% confidence interval: 1.2 to 5.3; p = 0.015) in HCM and remained significant even after correcting for LGE, ECV, and wall thickness (p = 0.036). CONCLUSIONS: DT-CMR assessment of left ventricular myoarchitecture matched patterns reported previously on histology. Low diastolic FA in HCM was associated with ventricular arrhythmia and is likely to represent disarray after accounting for fibrosis. The authors propose that diastolic FA could be the first in vivo marker of disarray in HCM and a potential independent risk factor.

来源:J Am Coll Cardiol,查看原文。版权归原作者所有。

引用

  1. Ariga R, Tunnicliffe EM, Manohar SG, et al. Identification of Myocardial Disarray in Patients With Hypertrophic Cardiomyopathy and Ventricular Arrhythmias. J Am Coll Cardiol. 2019. PMID: 31118142. doi:10.1016/j.jacc.2019.02.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。