左束支传导阻滞时急性心肌梗死的诊断
该研究在三个国际前瞻性诊断研究中评估了因胸部不适就诊于26个急诊科的8830例患者,其中247例(2.8%)存在左束支传导阻滞(LBBB)。LBBB患者中30%最终诊断为急性心肌梗死(AMI),已知LBBB与推测新发LBBB的AMI发生率相似(29% vs 35%,p=0.42)。心电图标准敏感度低(1%-12%)但特异度高(95%-100%),而高敏肌钙蛋白T/I及其0/1小时或0/2小时变化诊断准确性很高,联合心电图标准与肌钙蛋白的算法在外部验证中表现良好。
要点
- LBBB患者中仅30%最终诊断为AMI,多数为其他诊断。
- 心电图标准诊断AMI敏感度低(1%-12%),特异度高(95%-100%)。
- 联合心电图与高敏肌钙蛋白0/1或0/2小时检测可早期准确诊断AMI。
核心结论
- 多数疑似AMI的LBBB患者最终诊断为非AMI。
- 联合心电图标准与高敏肌钙蛋白T/I在0/1小时或0/2小时的检测可实现LBBB患者AMI的早期准确诊断。
研究设计与样本
- 研究为三个国际前瞻性诊断研究,纳入因胸部不适就诊于26个急诊科的患者。
- 共8830例患者,其中247例(2.8%)存在LBBB。
- AMI最终诊断由两名独立心内科医生根据心肌梗死通用定义集中裁定。
主要发现
- LBBB患者中AMI最终诊断率为30%。
- 已知LBBB与推测新发LBBB的AMI发生率相似(29% vs 35%,p=0.42)。
- 心电图标准诊断AMI的敏感度为1%-12%,特异度为95%-100%。
- 高敏肌钙蛋白T就诊时浓度ROC曲线下面积(AUC)为0.91(95% CI 0.85 to 0.96)。
- 高敏肌钙蛋白I就诊时浓度AUC为0.89(95% CI 0.83 to 0.95),其0/1小时和0/2小时变化诊断准确性也很高。
关键数值与推荐
- 联合心电图标准与高敏肌钙蛋白T/I浓度及其1小时或2小时绝对变化的诊断算法在队列1中正确识别45/45例(100%)AMI患者。
- 该算法在队列2和3外部验证中正确识别28/29例(97%)患者。
临床怎么用
- 对于疑似AMI的LBBB患者,应结合心电图标准与高敏肌钙蛋白T/I的0/1小时或0/2小时动态检测进行早期诊断。
- 心电图标准敏感度低,不能单独用于排除AMI。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Patients with suspected acute myocardial infarction (AMI) in the setting of left bundle branch block (LBBB) present an important diagnostic and therapeutic challenge to the clinician. METHODS: We prospectively evaluated the incidence of AMI and diagnostic performance of specific ECG and high-sensitivity cardiac troponin (hs-cTn) criteria in patients presenting with chest discomfort to 26 emergency departments in three international, prospective, diagnostic studies. The final diagnosis of AMI was centrally adjudicated by two independent cardiologists according to the universal definition of myocardial infarction. RESULTS: Among 8830 patients, LBBB was present in 247 (2.8%). AMI was the final diagnosis in 30% of patients with LBBB, with similar incidence in those with known LBBB versus those with presumably new LBBB (29% vs 35%, p=0.42). ECG criteria had low sensitivity (1%-12%) but high specificity (95%-100%) for AMI. The diagnostic accuracy as quantified by the receiver operating characteristics (ROC) curve of hs-cTnT and hs-cTnI concentrations at presentation (area under the ROC curve (AUC) 0.91, 95% CI 0.85 to 0.96 and AUC 0.89, 95% CI 0.83 to 0.95), as well as that of their 0/1-hour and 0/2-hour changes, was very high. A diagnostic algorithm combining ECG criteria with hs-cTnT/I concentrations and their absolute changes at 1 hour or 2 hours derived in cohort 1 (45 of 45(100%) patients with AMI correctly identified) showed high efficacy and accuracy when externally validated in cohorts 2 and 3 (28 of 29 patients, 97%). CONCLUSION: Most patients presenting with suspected AMI and LBBB will be found to have diagnoses other than AMI. Combining ECG criteria with hs-cTnT/I testing at 0/1 hour or 0/2 hours allows early and accurate diagnosis of AMI in LBBB. TRIAL REGISTRATION NUMBER: APACE: NCT00470587; ADAPT: ACTRN12611001069943; TRAPID-AMI: RD001107;Results.
引用
- Nestelberger T, Cullen L, Lindahl B, et al. Diagnosis of acute myocardial infarction in the presence of left bundle branch block. Heart. 2019. PMID: 31142594. doi:10.1136/heartjnl-2018-314673
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。