文献速递瓣膜病与结构性心脏病

瓣口面积与主动脉瓣狭窄高估风险

Valve area and the risk of overestimating aortic stenosis.
PubMed 文献 · Heart · 2019-02-16

结果显示,无瓣膜梗阻者中AVA≤1.0 cm²和≤1.5 cm²的比例分别为0.5%和3.1%(正常瓣膜)及1.8%和9.3%(主动脉瓣硬化),提示现有cutoff值可能在无AS患者中检出小AVA,血流校正指标可能高估AS。

要点

  • 正常瓣膜者AVA≤1.0 cm²的比例为0.5%,主动脉瓣硬化者为1.8%。
  • 无梗阻患者中Vratio≤0.25的比例为0.1%。
  • 小AVA风险因素包括主动脉瓣硬化、女性、体表面积小、低射血分数和二尖瓣反流。

核心结论

  • 连续方程衍生的正常AVA值小于既往认为的数值。
  • 无AS患者中可发现低于中重度AScutoff的AVA值。
  • 血流校正指标可能高估低梯度患者的AS,尤其存在明确风险因素时。

主要发现

  • 正常瓣膜者AVA≤1.0 cm²占0.5%,≤1.5 cm²占3.1%;主动脉瓣硬化者分别为1.8%和9.3%。
  • 无梗阻患者中Vratio≤0.25占0.1%。
  • 无梗阻患者小AVA的风险因素为主动脉瓣硬化、女性、小体表面积、低射血分数和二尖瓣反流。

临床怎么用

  • 解读AVA时需结合血流校正指标和形态学,避免在低梯度患者中高估AS。
  • 对于存在主动脉瓣硬化、女性、小体表面积、低射血分数或二尖瓣反流的患者,应警惕AVA假性变小。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To obtain reference values of aortic valve area (AVA) in a large population and to infer the risk of overestimating aortic stenosis (AS) when focusing on flow-corrected indices of severity. METHODS: We prospectively measured indices of AS in all consecutive echocardiograms performed in a large referral cardiac imaging laboratory for 1 year. We specifically analysed the distribution of AVA, indexed AVA and velocity ratio (Vratio) in patients with and without AS, the latter defined as the coexistence of valvular outflow obstruction (Vmax ≥2.5 m/s) and morphological findings of valve degeneration. RESULTS: 16 156 echocardiograms were analysed, 14 669 of which did not show valvular obstruction (peak jet velocity <2.5 m/s). In the latter group, AVA was 2.6±0.7 cm2 in 8190 studies with normal valves and 2.3±0.7 cm2 in 6479 studies with aortic sclerosis (AScl). There was a relatively wide overlap between values of AVA, indexed AVA and velocity ratio between studies of patients with AScl and AS. Values of AVA ≤1.0 cm2 were found in 0.5% of studies with normal valves and 1.8% of studies with AScl. These proportions were 3.1% and 9.3% for AVA ≤1.5 cm2, respectively. Vratio ≤0.25 were found in 0.1% of patients without obstruction. Risk factors for a small AVA in patients without obstruction were AScl, female sex, small body surface area, low ejection fraction and mitral regurgitation. CONCLUSIONS: Normal values of continuity-equation derived AVA are smaller than previously considered. AVA values below cutoffs of moderate or severe AS can be found in patients without the disease. Flow-corrected indices may overestimate AS in patients with low gradients, particularly in the presence of well-identified risk factors.

来源:Heart,查看原文。版权归原作者所有。

引用

  1. González-Mansilla A, Martinez-Legazpi P, Prieto A, et al. Valve area and the risk of overestimating aortic stenosis. Heart. 2019. PMID: 30772823. doi:10.1136/heartjnl-2018-314482