文献速递心律失常瓣膜病与结构性心脏病

左室机械离散度预测二尖瓣脱垂患者心律失常风险

Left ventricular mechanical dispersion predicts arrhythmic risk in mitral valve prolapse.
PubMed 文献 · Heart · 2019-02-12

本研究纳入32例有心律失常并发症的二尖瓣脱垂(MVP)患者、27例无心律失常并发症的MVP患者及39例对照,采用斑点追踪超声心动图(STE)计算左室整体纵向应变(GLS)和机械离散度。结果显示心律失常性MVP的机械离散度显著高于无心律失常MVP(59 vs 43 ms,p=0.0002),且多因素分析中机械离散度是心律失常风险的唯一显著预测因子(OR 1.1,95%CI 1.02-1.11,p=0.006)。

要点

  • MVP患者机械离散度显著高于对照(52 vs 42 ms,p=0.005)。
  • 心律失常性MVP机械离散度高于无心律失常MVP(59 vs 43 ms,p=0.0002)。
  • 机械离散度是多因素分析中心律失常风险的唯一显著预测因子。

核心结论

  • STE衍生的机械离散度可能有助于识别心律失常风险较高的MVP患者。

研究设计与样本

  • 研究纳入32例有心律失常并发症的MVP(A-MVP),其中23例Holter/事件监测显示复杂室性早搏、9例植入除颤器;另纳入27例无心律失常并发症的MVP(NA-MVP)和39例对照。
  • 采用斑点追踪超声心动图计算左室整体纵向应变(GLS)和机械离散度(各节段达峰应变时间的标准差)。

主要发现

  • MVP患者机械离散度显著高于对照(52 vs 42 ms,p=0.005),尽管左室射血分数(62% vs 63%,p=0.42)和GLS(-19.7 vs -21,p=0.045)相似。
  • A-MVP与NA-MVP人口学特征、左室射血分数和GLS均无显著差异(所有p>0.05)。
  • A-MVP双叶脱垂比例更高(69% vs 44%,p=0.031),二尖瓣反流程度相似(两组多为微量或轻度)(p>0.05)。
  • A-MVP机械离散度显著大于NA-MVP(59 vs 43 ms,p=0.0002)。
  • 多因素分析中机械离散度是心律失常风险的唯一显著预测因子(OR 1.1,95%CI 1.02-1.11,p=0.006)。

临床怎么用

  • 对于二尖瓣脱垂患者,可考虑应用斑点追踪超声心动图测量左室机械离散度以辅助心律失常风险分层。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Bileaflet mitral valve prolapse (MVP) with either focal or diffuse myocardial fibrosis has been linked to ventricular arrhythmia and/or sudden cardiac arrest. Left ventricular (LV) mechanical dispersion by speckle-tracking echocardiography (STE) is a measure of heterogeneity of ventricular contraction previously associated with myocardial fibrosis. The aim of this study is to determine whether mechanical dispersion can identify MVP at higher arrhythmic risk. METHODS: We identified 32 consecutive arrhythmic MVPs (A-MVP) with a history of complex ventricular ectopy on Holter/event monitor (n=23) or defibrillator placement (n=9) along with 27 MVPs without arrhythmic complications (NA-MVP) and 39 controls. STE was performed to calculate global longitudinal strain (GLS) as the average peak longitudinal strain from an 18-segment LV model and mechanical dispersion as the SD of the time to peak strain of each segment. RESULTS: MVPs had significantly higher mechanical dispersion compared with controls (52 vs 42 ms, p=0.005) despite similar LV ejection fraction (62% vs 63%, p=0.42) and GLS (-19.7 vs -21, p=0.045). A-MVP and NA-MVP had similar demographics, LV ejection fraction and GLS (all p>0.05). A-MVP had more bileaflet prolapse (69% vs 44%, p=0.031) with a similar degree of mitral regurgitation (mostly trace or mild in both groups) (p>0.05). A-MVP exhibited greater mechanical dispersion when compared with NA-MVP (59 vs 43 ms, p=0.0002). Mechanical dispersion was the only significant predictor of arrhythmic risk on multivariate analysis (OR 1.1, 95% CI 1.02 to 1.11, p=0.006). CONCLUSIONS: STE-derived mechanical dispersion may help identify MVP patients at higher arrhythmic risk.

来源:Heart,查看原文。版权归原作者所有。

引用

  1. Ermakov S, Gulhar R, Lim L, et al. Left ventricular mechanical dispersion predicts arrhythmic risk in mitral valve prolapse. Heart. 2019. PMID: 30755467. doi:10.1136/heartjnl-2018-314269

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。