文献速递冠心病

基于冠状动脉造影的无导丝FFR计算准确性研究

Accuracy of Fractional Flow Reserve Derived From Coronary Angiography.
PubMed 文献 · Circulation · 2019-01-01

FAST-FFR为前瞻性多中心国际试验,在301例患者319支血管中比较造影衍生的FFRangio与压力导丝FFR。以0.80为界,FFRangio的敏感性和特异性分别为94%和91%,总体诊断准确率92%。FFRangio与导丝FFR相关性良好(r=0.80,P<0.001),有望提升导管室内生理学评估的应用。

要点

  • FFRangio以压力导丝FFR≤0.80为参考,敏感性94%、特异性91%。
  • 总体诊断准确率92%,在FFR 0.75–0.85灰区仍达87%。
  • FFRangio与导丝FFR相关性r=0.80,设备成功率99%。

核心结论

  • 仅基于冠状动脉造影计算的FFRangio与压力导丝FFR相比具有高敏感性、高特异性和高准确率。
  • FFRangio有望在导管室大幅增加冠状动脉生理学评估的应用,从而可能改善患者结局。

研究设计与样本

  • 共纳入301例受试者、319支符合入选/排除标准的血管进入最终分析。
  • 在常规冠状动脉造影后,由对FFR设盲的现场操作者使用专有软件基于≥2个体位造影计算FFRangio。
  • 共同主要终点为FFRangio以0.80为界二分类预测压力导丝FFR的敏感性和特异性。

主要发现

  • 平均FFR为0.81,43%的血管FFR≤0.80。
  • 按血管计算的敏感性和特异性分别为94%(95%CI,88%–97%)和91%(86%–95%),均超过预设性能目标。
  • FFRangio总体诊断准确率为92%,仅考虑FFR值在0.75至0.85之间时仍达87%。
  • FFRangio值与FFR测量值相关性良好(r=0.80,P<0.001),Bland-Altman 95%置信限为-0.14至0.12。
  • FFRangio的设备成功率为99%。

关键数值与推荐

  • FFRangio以压力导丝FFR≤0.80为参考标准进行二分类评分。
  • 敏感性94%(95%CI,88%–97%)和特异性91%(86%–95%)均超过预设性能目标。
  • 总体诊断准确率92%,FFR 0.75–0.85范围内准确率87%。
  • FFRangio与FFR相关性r=0.80(P<0.001),Bland-Altman 95%置信限-0.14至0.12。
  • 设备成功率99%。

临床怎么用

  • 在常规冠状动脉造影基础上,可无需压力导丝和充血刺激即可计算FFRangio评估整个冠状动脉树的FFR值。
  • FFRangio对以0.80为界判断血流动力学显著狭窄具有高敏感性和特异性,可作为压力导丝FFR的替代评估手段。
  • 该技术有望在导管室增加冠状动脉生理学评估的应用,但临床结局获益尚需进一步验证。

局限性

  • 原文摘要未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Measuring fractional flow reserve (FFR) with a pressure wire remains underutilized because of the invasiveness of guide wire placement or the need for a hyperemic stimulus. FFR derived from routine coronary angiography (FFRangio) eliminates both of these requirements and displays FFR values of the entire coronary tree. The FFRangio Accuracy versus Standard FFR (FAST-FFR) study is a prospective, multicenter, international trial with the primary goal of determining the accuracy of FFRangio. METHODS: Coronary angiography was performed in a routine fashion in patients with suspected coronary artery disease. FFR was measured in vessels with coronary lesions of varying severity using a coronary pressure wire and hyperemic stimulus. Based on angiograms of the respective arteries acquired in ≥2 different projections, on-site operators blinded to FFR then calculated FFRangio using proprietary software. Coprimary end points were the sensitivity and specificity of the dichotomously scored FFRangio for predicting pressure wire-derived FFR using a cutoff value of 0.80. The study was powered to meet prespecified performance goals for sensitivity and specificity. RESULTS: Ten centers in the United States, Europe, and Israel enrolled a total of 301 subjects and 319 vessels meeting inclusion/exclusion criteria which were included in the final analysis. The mean FFR was 0.81 and 43% of vessels had an FFR≤0.80. The per-vessel sensitivity and specificity were 94% (95% CI, 88% to 97%) and 91% (86% to 95%), respectively, both of which exceeded the prespecified performance goals. The diagnostic accuracy of FFRangio was 92% overall and remained high when only considering FFR values between 0.75 to 0.85 (87%). FFRangio values correlated well with FFR measurements ( r=0.80, P<0.001) and the Bland-Altman 95% confidence limits were between -0.14 and 0.12. The device success rate for FFRangio was 99%. CONCLUSIONS: FFRangio measured from the coronary angiogram alone has a high sensitivity, specificity, and accuracy compared with pressure wire-derived FFR. FFRangio has the promise to substantially increase physiological coronary lesion assessment in the catheterization laboratory, thereby potentially leading to improved patient outcomes. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique Identifier: NCT03226262.

来源:Circulation,查看原文。版权归原作者所有。

引用

  1. Fearon WF, Achenbach S, Engstrom T, et al. Accuracy of Fractional Flow Reserve Derived From Coronary Angiography. Circulation. 2019. PMID: 30586699. doi:10.1161/CIRCULATIONAHA.118.037350

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。