文献速递冠心病血脂与心血管预防

血管内超声对冠心病患者的预后价值

Prognostic Value of Intravascular Ultrasound in Patients With Coronary Artery Disease.
PubMed 文献 · J Am Coll Cardiol · 2018-01-01

研究纳入581例因急性冠脉综合征或稳定心绞痛行冠脉造影的患者,对非罪犯血管的非狭窄段行(射频)血管内超声检查,中位随访4.7年。结果显示最小管腔面积≤4.0 mm²与主要不良心血管事件独立相关,而薄纤维帽粥样斑块或斑块负荷≥70%单独未显示独立关联。

要点

  • 最小管腔面积≤4.0 mm²是非罪犯病变长期MACE的独立预测因素。
  • 薄纤维帽粥样斑块或斑块负荷≥70%单独未独立预测MACE。
  • 排除罪犯病变相关事件后,斑块负荷≥70%与心脏死亡、非致命ACS或非计划血运重建复合终点独立相关。

核心结论

  • IVUS衍生的最小管腔面积≤4.0 mm²和较大斑块负荷可预测冠心病患者长期不良心血管结局。
  • 射频IVUS衍生的斑块成分特征单独未显示独立预测价值。

研究设计与样本

  • 2008至2011年,581例因急性冠脉综合征或稳定心绞痛行冠脉造影的患者,对一条非罪犯冠脉的非狭窄段行(射频)血管内超声检查。
  • 预设主要终点为主要不良心血管事件,即全因死亡、非致命ACS或非计划血运重建的复合终点。
  • 风险比经年龄、性别和临床危险因素校正。

主要发现

  • 中位随访4.7年,152例(26.2%)发生MACE。
  • 最小管腔面积≤4.0 mm²的病变与MACE独立相关(HR: 1.49; 95% CI: 1.07 to 2.08; p = 0.020)。
  • 薄纤维帽粥样斑块病变或斑块负荷≥70%的病变单独与MACE无独立关联。
  • 以心脏死亡替代全因死亡的复合终点结果相似。
  • 排除罪犯病变相关事件后,斑块负荷≥70%的病变与心脏死亡、非致命ACS或非计划血运重建复合终点独立相关(HR: 1.66; 95% CI: 1.06 to 2.58; p = 0.026)。

临床怎么用

  • 对冠心病患者非罪犯病变行IVUS评估时,最小管腔面积≤4.0 mm²和斑块负荷≥70%可辅助长期风险分层。
  • 射频IVUS斑块成分特征单独不推荐用于独立预后判断。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: It has been shown that intravascular ultrasound (IVUS) and radiofrequency (RF-)IVUS can detect high-risk coronary plaque characteristics. OBJECTIVES: The authors studied the long-term prognostic value of (RF-)IVUS-derived plaque characteristics in patients with coronary artery disease (CAD) undergoing coronary angiography. METHODS: From 2008 to 2011, (RF-)IVUS was performed in 1 nonstenotic segment of a nonculprit coronary artery in 581 patients undergoing coronary angiography for acute coronary syndrome (ACS) or stable angina. The pre-defined primary endpoint was major adverse cardiovascular events (MACE), defined as the composite of all-cause death, nonfatal ACS, or unplanned revascularization. Hazard ratios (HRs) were adjusted for age, sex, and clinical risk factors. RESULTS: During a median follow-up of 4.7 years, 152 patients (26.2%) had MACE. The presence of a lesion with a minimal luminal area ≤4.0 mm2 was independently associated with MACE (HR: 1.49; 95% CI: 1.07 to 2.08; p = 0.020), whereas the presence of a thin-cap fibroatheroma lesion or a lesion with a plaque burden ≥70% on its own were not. Results were comparable when the composite endpoint included cardiac death instead of all-cause death. The presence of a lesion with a plaque burden of ≥70% was independently associated with the composite endpoint of cardiac death, nonfatal ACS, or unplanned revascularization after exclusion of culprit lesion-related events (HR: 1.66; 95% CI: 1.06 to 2.58; p = 0.026). Likewise, each 10-U increase in segmental plaque burden was independently associated with a 26% increase in risk of this composite endpoint (HR: 1.26 per 10-U increase; 95% CI: 1.03 to 1.52; p = 0.022). CONCLUSIONS: IVUS-derived small luminal area and large plaque burden, and not RF-IVUS-derived compositional plaque features on their own, predict adverse cardiovascular outcome during long-term follow-up in patients with CAD. (The European Collaborative Project on Inflammation and Vascular Wall Remodeling in Atherosclerosis-Intravascular Ultrasound Study [AtheroRemoIVUS]; NCT01789411).

来源:J Am Coll Cardiol,查看原文。版权归原作者所有。

引用

  1. Schuurman AS, Vroegindewey MM, Kardys I, et al. Prognostic Value of Intravascular Ultrasound in Patients With Coronary Artery Disease. J Am Coll Cardiol. 2018. PMID: 30336823. doi:10.1016/j.jacc.2018.08.2140

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。