主动脉根部形态对二叶式主动脉瓣狭窄TAVR瓣膜置入深度的影响
回顾性分析40例二叶式主动脉瓣狭窄患者采用Venus-A自膨胀瓣膜行TAVR,按瓣膜置入深度分为未过深组(≤10 mm,29例)和过深组(>10 mm,11例)。过深组主动脉-左心室成角更大、瓣叶钙化呈轻度或重度比例更高、左心室流出道周长/瓣环周长更大,且住院期间新发传导阻滞比例更高、术后30天左心室射血分数更低。结论认为主动脉根部形态与瓣膜置入深度相关,并可能影响传导系统及左心室功能。
要点
- 二叶式主动脉瓣TAVR中,主动脉-左心室成角大、瓣叶钙化呈轻度或重度、左心室流出道周长/瓣环周长更大者更易发生瓣膜置入过深。
- 瓣膜置入过深者住院期间新发束支传导阻滞或房室传导阻滞比例更高(6/11比2/29,P=0.030)。
- 瓣膜置入过深者术后30天左心室射血分数低于未过深组[(51.6±12.8)%比(60.9±8.1)%,P=0.020]。
核心结论
- 二叶式主动脉瓣狭窄患者主动脉根部形态特点与TAVR术中瓣膜置入深度有一定关系,并可能影响术后心脏传导系统及左心室功能。
研究设计与样本
- 回顾性分析2014年1月至2017年10月阜外医院40例采用Venus-A自膨胀式人工主动脉瓣膜行TAVR的二叶式主动脉瓣狭窄患者临床资料。
- 按术中即刻造影测量的第1个人工瓣膜下缘与瓣环距离分为未过深组(≤10 mm,29例)和过深组(>10 mm,11例)。
- 患者均在术前检查CT,记录主动脉根部钙化、角度和径线等形态学特点。
主要发现
- 患者年龄(75.1±5.9)岁,带嵴二叶式主动脉瓣21例(52.5%),无嵴二叶式主动脉瓣19例(47.5%)。
- 过深组主动脉-左心室成角大于未过深组[(56.5±4.5)°比(47.4±9.4)°,P=0.004]。
- 过深组左心室流出道周长/瓣环周长大于未过深组[(109.2±7.5)%比(101.5±6.5)%,P=0.004]。
- 住院期间过深组新发束支传导阻滞或房室传导阻滞比例高于未过深组(6/11比2/29,P=0.030)。
临床怎么用
- 对于二叶式主动脉瓣狭窄患者,术前CT评估主动脉-左心室成角、瓣叶钙化体积及左心室流出道周长/瓣环周长有助于预判TAVR瓣膜置入过深风险。
- 术中应关注瓣膜置入深度,置入过深者需警惕新发传导阻滞及术后左心室射血分数降低。
局限性
- 本研究为单中心回顾性分析,样本量40例,过深组仅11例,结论需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To investigate the impact of aortic root morphology on the implantation depth of aortic valve prosthesis during trans-catheter aortic valve replacement (TAVR) in bicuspid aortic valve patients. Methods: Clinical data of 40 patients with native bicuspid aortic valve stenosis who underwent TAVR using the self-expandable prosthesis (the Venus A-valve) from 2014 to 2017 in Fuwai Hospital was retrospectively analyzed. The patients were divided into non-deep implantation group (implant depth ≤10 mm by instant angiogram after implantation,29 cases) and deep implantation group (implant depth> 10 mm by instant angiogram after implantation,11 cases).Pre-procedural aortic root characteristics (e.g. calcification, angle and dimensions) were assessed by CT. The impact of aortic root morphology on the implantation depth and clinical outcomes were also evaluated. Results: The age was (75.1±5.9) years with equal representation from the raphe-type and non-raphe type (52.5%(21/40) and 47.5%(19/40)).The bigger aorta angle ((56.5±4.5)° vs. (47.4±9.4)°, P=0.004),more frequent mild-calcification (HU850, <200 mm(3)) or severe-calcification(HU850, >1 000 mm(3)) of aortic leaflets (7/11 vs. 4/29, P=0.006), as well as higher ratio of left ventricular outflow tract perimeter to annulus perimeter ((109.2±7.5)% vs. (101.5±6.5)%, P=0.004) were found in the deep implantation group compared to the non-deep implantation group. The new in-hospital onset of bundle-branchheart-block or atrioventricular block conduction disturbance rate was higher in the deep implantation group than in the non-deep implantation group (6/11 vs. 2/29, P=0.030).Left ventricular ejection fraction was similar between deep implantation group and non-deep implantation group at baseline((49.9±8.9)% vs. (55.8±10.4)%, P=0.117), and was significantly lower in the deep implantation group than in the non-deep implantation group at 30 days after implantation ((51.6±12.8)% vs. (60.9±8.1)%, P=0.020). Conclusion: Aortic root morphology of bicuspid aortic valve patients is associated with implantation depth of the prosthesis during TAVR, which affects the conduction system and left ventricular function during and post TAVR. 目的: 探讨二叶式主动脉瓣狭窄患者主动脉根部形态学特点对经导管主动脉瓣置换术(TAVR)中瓣膜置入深度的影响。 方法: 回顾性分析2014年1月至2017年10月在阜外医院采用Venus-A自膨胀式人工主动脉瓣膜行TAVR的40例二叶式主动脉瓣狭窄患者的临床资料,并将患者分为瓣膜置入未过深组(术中即刻造影图像测量的第1个人工瓣膜下缘与瓣环距离≤10 mm,29例)和瓣膜置入过深组(术中即刻造影图像测量的第1个人工瓣膜下缘与瓣环距离>10 mm,11例)。患者均在术前检查CT,记录主动脉根部钙化、角度和径线等形态学特点,分析其对TAVR术中瓣膜置入深度及预后的影响。 结果: 患者年龄(75.1±5.9)岁,无嵴二叶式主动脉瓣19例(占47.5%),带嵴二叶式主动脉瓣21例(占52.5%)。与瓣膜置入未过深组比较,瓣膜置入过深组主动脉-左心室成角更大[(56.5±4.5)°比(47.4±9.4)°,P=0.004],主动脉瓣钙化体积(HU850)<200 mm(3)或>1 000 mm(3)的比例更高(7/11比4/29,P=0.006),左心室流出道周长/瓣环周长更大[(109.2±7.5)%比(101.5±6.5)%,P=0.004]。住院期间,瓣膜置入过深组患者新发束支传导阻滞或房室传导阻滞比例高于瓣膜置入未过深组(6/11比2/29,P=0.030)。术前瓣膜置入过深组与瓣膜置入未过深组患者的左心室射血分数差异无统计学意义[(49.9±8.9)%比(55.8±10.4)%,P=0.117],术后30 d瓣膜置入过深组患者的左心室射血分数低于瓣膜置入未过深组[(51.6±12.8)%比(60.9±8.1)%,P=0.020]。 结论: 二叶式主动脉瓣狭窄患者的主动脉根部形态特点与TAVR术中瓣膜置入深度有一定关系,并可能影响术后心脏传导系统及左心室功能。.
引用
- Wang MY, Song GY, Wang Y, et al. [Impact of aortic root morphology on the implantation depth of aortic valve prosthesis during trans-catheter aortic valve replacement in patients with native bicuspid aortic valve stenosis]. Zhonghua Xin Xue Guan Bing Za Zhi. 2018. PMID: 30139014. doi:10.3760/cma.j.issn.0253-3758.2018.08.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。