梅氏微创消融术治疗导管消融失败房颤患者的临床结果
本研究回顾性分析48例既往1~3次导管消融失败的房颤患者,接受梅氏微创消融术(胸腔镜下双极射频环肺静脉隔离、左房顶部和后壁线性消融、心外膜自主神经节消融及左心耳切除)。出院时91.7%维持窦性心律,平均随访28.0个月后82.6%维持窦性心律,无严重并发症及卒中、肺静脉狭窄或左房血栓。
要点
- 导管消融失败后行梅氏微创消融术仍可获得较高窦性心律维持率。
- 术后平均随访28.0个月,82.6%患者维持窦性心律且无严重并发症。
- 长程持续性房颤成功率低于阵发性房颤,但差异无统计学意义(P>0.05)。
核心结论
- 梅氏微创消融术对导管消融失败的房颤患者有较高成功率,可完整隔离双侧肺静脉和左房后壁并同期切除左心耳。
研究设计与样本
- 回顾性分析2011年8月至2016年5月在上海新华医院住院的48例经导管消融失败后接受梅氏微创消融术的房颤患者,男29例、女19例,年龄(62.5±7.3)岁。
- 48例中阵发性房颤8例、持续性房颤15例、长程持续性房颤25例,术前接受过1~3次导管消融术。
主要发现
- 出院时44例(91.7%)维持窦性心律,平均随访(28.0±17.2)个月后38例(82.6%)维持窦性心律。
- 8例阵发性房颤中7例转复成功,38例非阵发性房颤中31例转复为窦性心律,15例持续性房颤中13例转复为窦性心律。
- 随访期间无卒中等脑血管不良事件、无肺静脉狭窄和左心房血栓。
- Kaplan-Meier曲线分析显示长程持续性房颤成功率低于阵发性房颤,但差异无统计学意义(P>0.05)。
关键数值与推荐
- 48例患者房颤病史(8.1±6.3)年,左心房直径(44.1±6.2)mm。
- 全部患者手术时间(142.3±35.6)min,住院(9.3±1.8)d,无严重并发症。
- 21例患者心包内有不同程度粘连,均予顺利分离。
临床怎么用
- 对于既往导管消融失败的房颤患者,梅氏微创消融术可作为可选的治疗策略,其左心房消融路线完整、消融线质量较高。
- 术中可同期切除左心耳,术后随访需关注窦性心律维持情况。
局限性
- 本研究为单中心回顾性分析,样本量48例,随访时间(28.0±17.2)个月,长程持续性房颤成功率低于阵发性房颤但差异无统计学意义。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To evaluate the efficacy of Mei mini maze procedure for treating atrial fibrillation (AF) patients with previously failed catheter ablation. Methods: Between August 2010 and May 2016, 48 AF (8 proximal AF, 15 persistent AF and 25 long-standing persistent AF) patients (29 males, 19 females, mean age: (62.5±7.3) years old) with previously 1-3 failed catheter ablation results were treated with Mei mini maze procedure in our department. Under thoracoscopic assistance, the procedure was performed through three ports on left chest wall, pulmonary vein isolation and ablations of the roof and posterior wall of left atrium was made by bipolar radiofrequency ablation. Ganglionic plexus ablation was made by the ablation pen. Left atrial appendage was excluded. Patients were followed at outpatient clinic and per telephone. Electrocardiogram, CT and echocardiography examinations were performed at 1, 3, 6 and 12 months post operation. The success rate of the procedure was analyzed by Kaplan-Meier curves and evaluated by the log-rank test. Results: Mean AF history was (8.1±6.3) years and left atria dimension was (44.1±6.2) mm in this patient cohort. All procedures were performed successfully in these 48 patients. Pericardial adhesions were dissected in 21 patients. Durations of the procedures were (142.3±35.6) minutes.There were no serious complications. The hospital stay was (9.3±1.8) days. Sinus rhythm was documented in 44 patients (91.7%) at discharge. The mean follow-up duration was (28.0±17.2) months. Thirty-eight patients (82.6%) were in sinus rhythm. There was no stroke, thrombus in the left atrium and stenosis of pulmonary vein during the follow-up. Sinus rhythm was achieved in 7 out of 8 paroxysmal AF patients, in 31 out of 38 non-paroxysmal AF patients, and in 13 out of 15 persistent AF patients. Kaplan-Meier curve showed that the success rate in the long-standing persistent AF group was lower than in the other two groups, but there was no statistical difference. Conclusions: Mei mini maze procedure has a high success rate for AF patients with previously failed catheter ablation history, which could completely isolate the bilateral pulmonary vein and left atrial posterior wall with good quality and integrity of ablation line, and left atrial appendage is also resected during the procedure. 目的: 分析梅氏微创消融术治疗对导管消融失败的心房颤动(房颤)患者的临床结果。 方法: 回顾性分析2011年8月至2016年5月,在上海新华医院住院的48例经导管消融失败后接受梅式微创消融术的房颤患者,其中男29例,女19例,年龄(62.5±7.3)岁。48例患者中阵发性房颤8例,持续性房颤15例,长程持续性房颤25例,术前接受过1~3次的导管消融术。手术经左胸路径,在全胸腔镜下施行,房颤消融术式包括双极消融钳行双侧环肺静脉消融、连接两侧肺静脉的左心房顶部和左心房后壁线性消融,Marshall韧带、心外膜自主神经节消融和左心耳切除等。采用门诊复诊和电话等方式进行随访,术后1、3、6和12个月复查心电图、CT和心脏超声心动图。用Kaplan-Meier曲线分析治疗的成功率,log-rank法进行检验。 结果: 48例患者房颤病史(8.1±6.3)年,左心房直径(44.1±6.2)mm。均顺利完成手术,21例患者心包内有不同程度的粘连,均予顺利分离。全部患者手术时间(142.3±35.6)min。所有患者无严重并发症,住院(9.3±1.8)d。44例(91.7%)出院时维持窦性心律。术后随访(28.0±17.2)个月,仍有38例(82.6%)维持窦性心律。随访期间所有患者无卒中等脑血管不良事件,无肺静脉狭窄和左心房血栓。8例阵发性房颤患者7例转复成功,38例非阵发性房颤患者31例转复为窦性心律,15例持续性房颤患者13例转复为窦性心律。Kaplan-Meier曲线分析显示长程持续性房颤的成功率低于阵发性房颤,但差异无统计学意义(P>0.05)。 结论: 梅氏消融术的左心房消融路线完整,各消融线质量较高,可以完全隔离双侧肺静脉和左心房后壁,同期切除左心耳,对于导管消融失败的患者也有较高的成功率。.
引用
- Ma N, Mei J, Lu RX, et al. [Clinical results of Mei mini maze procedure for atrial fibrillation patients with previously failed catheter ablation]. Zhonghua Xin Xue Guan Bing Za Zhi. 2018. PMID: 30139009. doi:10.3760/cma.j.issn.0253-3758.2018.08.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。