PROTECTION VI:心血管CT成像辐射暴露显著降低——2017年多中心注册研究
结果显示冠状动脉CTA的中位剂量长度乘积(DLP)为195 mGy*cm,较2007年降低78%(P < 0.001),且非诊断性冠状动脉CTA比例未增加(2007年1.7% vs 2017年1.9%,P = 0.55)。但医院间中位DLP差异达37倍(范围57-2090 mGy*cm),提示仍需针对性地培训和优化扫描方案。
要点
- 2017年冠状动脉CTA中位DLP为195 mGy*cm,较2007年降低78%。
- 非诊断性冠状动脉CTA比例未增加(1.7% vs 1.9%,P=0.55)。
- 医院间中位DLP差异达37倍,需针对性培训优化方案。
核心结论
- 过去十年冠状动脉CTA辐射暴露显著降低,但院间差异巨大,需进一步站点特异性培训和方案优化。
主要发现
- 冠状动脉CTA最常见适应证为评估冠状动脉疾病,占89%患者。
- 冠状动脉CTA中位DLP为195 mGy*cm(四分位距110-338 mGy*cm)。
- 与2007年相比,DLP降低78%(P < 0.001),非诊断性冠状动脉CTA比例无增加(1.7% vs 1.9%,P = 0.55)。
- 医院间中位DLP差异达37倍(中位DLP范围57-2090 mGy*cm)。
- 辐射剂量的独立预测因素包括体重、心率、窦性心律、管电压、迭代图像重建和扫描方案选择。
临床怎么用
- 临床实践中应优先采用低剂量扫描策略(如根据体重和心率调整管电压、使用迭代重建、选择合适扫描方案)以降低辐射暴露。
- 医院间辐射剂量差异巨大,提示需开展站点特异性培训和当代心脏扫描方案适配。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Advances of cardiac computed tomography angiography (CTA) have been developed for dose reduction, but their efficacy in clinical practice is largely unknown. This study was designed to evaluate radiation dose exposure and utilization of dose-saving strategies for contrast-enhanced cardiac CTA in daily practice. METHODS AND RESULTS: Sixty one hospitals from 32 countries prospectively enrolled 4502 patients undergoing cardiac CTA during one calendar month in 2017. Computed tomography angiography scan data and images were analysed in a central core lab and compared with a similar dose survey performed in 2007. Linear regression analysis was performed to identify independent predictors associated with dose. The most frequent indication for cardiac CTA was the evaluation of coronary artery disease in 89% of patients. The median dose-length product (DLP) of coronary CTA was 195 mGy*cm (interquartile range 110-338 mGy*cm). When compared with 2007, the DLP was reduced by 78% (P < 0.001) without an increase in non-diagnostic coronary CTAs (1.7% in 2007 vs. 1.9% in 2017 surveys, P = 0.55). A 37-fold variability in median DLP was observed between the hospitals with lowest and highest DLP (range of median DLP 57-2090 mGy*cm). Independent predictors for radiation dose of coronary CTA were: body weight, heart rate, sinus rhythm, tube voltage, iterative image reconstruction, and the selection of scan protocols. CONCLUSION: This large international radiation dose survey demonstrates considerable reduction of radiation exposure in coronary CTA during the last decade. However, the large inter-site variability in radiation exposure underlines the need for further site-specific training and adaptation of contemporary cardiac scan protocols.
引用
- Stocker TJ, Deseive S, Leipsic J, et al. Reduction in radiation exposure in cardiovascular computed tomography imaging: results from the PROspective multicenter registry on radiaTion dose Estimates of cardiac CT angIOgraphy iN daily practice in 2017 (PROTECTION VI). Eur Heart J. 2018. PMID: 30165629. doi:10.1093/eurheartj/ehy546
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。