文献速递瓣膜病与结构性心脏病

常规超声心动图数据在重度主动脉瓣狭窄诊断中的应用

Use of routinely captured echocardiographic data in the diagnosis of severe aortic stenosis.
PubMed 文献 · Heart · 2018-06-20

相对于记录的解读,主动脉瓣面积(AVA)诊断重度主动脉瓣狭窄的敏感性高(94.1%)但阳性预测值低(37.5%);峰值流速和平均压差特异性高(>99%)但敏感性较低(<70%);结合峰值流速、平均压差和无量纲指数(通过速度时间积分或峰值流速比)的指标达到敏感性92%和特异性99%的平衡,准确性98.9% vs 99.3%略低于单独使用峰值流速和平均压差。使用所有可用数据,可评估主动脉瓣狭窄的患者比例为79.8%,而仅依据记录解读为52.7%。结论:使用无量纲指数替代AVA的指标解决了定量超声数据与记录解读之间的差异。

要点

  • AVA诊断重度AS敏感性高但阳性预测值低,峰值流速和平均压差特异性高但敏感性低。
  • 结合峰值流速、平均压差和无量纲指数的指标平衡敏感性92%和特异性99%。
  • 使用所有可用数据可评估AS的比例(79.8%)高于仅依据记录解读(52.7%)。

核心结论

  • 使用无量纲指数替代AVA的指标解决了定量超声数据与记录解读之间的差异。

主要发现

  • AVA诊断重度主动脉瓣狭窄的敏感性94.1%,阳性预测值37.5%。
  • 峰值流速和平均压差特异性>99%,敏感性<70%。
  • 结合峰值流速、平均压差和无量纲指数的指标敏感性92%,特异性99%,准确性98.9% vs 99.3%。
  • 使用所有可用数据可评估主动脉瓣狭窄的比例为79.8%,仅依据记录解读为52.7%。

关键数值与推荐

  • AVA诊断重度主动脉瓣狭窄的敏感性94.1%,阳性预测值37.5%。
  • 峰值流速和平均压差特异性>99%,敏感性<70%。
  • 结合峰值流速、平均压差和无量纲指数的指标敏感性92%,特异性99%,准确性98.9% vs 99.3%。

临床怎么用

  • 在常规超声数据中,使用无量纲指数替代AVA可提高与临床解读的一致性。
  • 结合峰值流速、平均压差和无量纲指数可平衡诊断敏感性和特异性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To determine the implications of applying guideline-recommended definitions of aortic stenosis to echocardiographic data captured in routine clinical care. METHODS: Retrospective observational study of 213 174 patients who underwent transthoracic echocardiographic imaging within Allina Health between January 2013 and October 2017. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of echocardiographic measures for severe aortic stenosis were determined relative to the documented interpretation of severe aortic stenosis. RESULTS: Among 77 067 patients with complete assessment of the aortic valve, 1219 (1.6%) patients were categorised as having severe aortic stenosis by the echocardiographic reader. Relative to the documented interpretation, aortic valve area (AVA) as a measure of severe aortic stenosis had the high sensitivity (94.1%) but a low positive predictive value (37.5%). Aortic valve peak velocity and mean gradient were specific (>99%), but less sensitive (<70%). A measure incorporating peak velocity, mean gradient and dimensionless index (either by velocity time integral or peak velocity ratio) achieved a balance of sensitivity (92%) and specificity (99%) with little detriment in accuracy relative to peak velocity and mean gradient alone (98.9% vs 99.3%). Using all available data, the proportion of patients whose echocardiogram could be assessed for aortic stenosis was 79.8% as compared with 52.7% by documented interpretation alone. CONCLUSION: A measure that used dimensionless index in place of AVA addressed discrepancies between quantitative echocardiographic data and the documented interpretation of severe aortic stenosis. These findings highlight the importance of understanding the limitations of clinical data as it relates to quality improvement efforts and pragmatic research design.

来源:Heart,查看原文。版权归原作者所有。

引用

  1. Bradley SM, Foag K, Monteagudo K, et al. Use of routinely captured echocardiographic data in the diagnosis of severe aortic stenosis. Heart. 2018. PMID: 29925543. doi:10.1136/heartjnl-2018-313269

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。