文献速递冠心病瓣膜病与结构性心脏病

自发性破裂主动脉斑块的血管镜评估

Angioscopic Evaluation of Spontaneously Ruptured Aortic Plaques.
PubMed 文献 · J Am Coll Cardiol · 2018-01-01

本研究为横断面研究,对324例连续诊断为或疑似冠心病的患者行主动脉内非阻塞性血管镜扫描,发现自发性破裂主动脉斑块(SRAP)存在于80.9%的患者中,120例位于膈肌水平以下;采样分析显示斑块尺寸小于既往认识,未观察到栓塞症状。

要点

  • SRAP在冠心病患者中常见,血管镜检出率80.9%。
  • SRAP尺寸较既往认为的小,胆固醇晶体长度中位数40μm。
  • 一般心脏导管护理后24小时内未观察到栓塞症状。

核心结论

  • 自发性破裂主动脉斑块常见且散在分布,其尺寸小于既往认识。

研究设计与样本

  • 横断面研究,纳入324例连续诊断为或疑似冠心病的患者,行主动脉内非阻塞性血管镜扫描。

主要发现

  • SRAP在262例(80.9%)患者中检出。
  • 262例中120例破裂主动脉斑块位于膈肌水平以下。
  • 482份样本中动脉粥样硬化物质、纤维蛋白、巨噬细胞和钙化的检出数分别为237(49.1%)、244(50.6%)、111(23.0%)和127(26.3%)。
  • 采样斑块长度和宽度中位数分别为254μm(IQR 100-685μm)和148μm(IQR 535-423.5μm)。
  • 胆固醇晶体长度和宽度中位数分别为40μm(IQR 32.7-53.7μm)和30μm(IQR 23-38μm),鬼影图像分别为86μm(IQR 53-119μm)和13μm(IQR 7-18μm)。

临床怎么用

  • 在冠心病患者中应考虑SRAP的普遍存在,但其临床栓塞意义需进一步评估。

局限性

  • 未报告SRAP与栓塞事件的长期关联,且24小时内未观察到栓塞症状。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Spontaneous ruptured aortic plaques (SRAP), which might cause atheromatous embolization, are thought to be mainly iatrogenic and have not been observed directly. OBJECTIVES: The purpose of this study was to clarify the incidence, types, and dimensions of SRAP using angioscopy. METHODS: In a cross-sectional study, 324 consecutive patients diagnosed with or suspected of having coronary artery disease were subjected to intra-aortic scans with nonobstructive angioscopy. Samples of SRAP were taken from the aorta. The dimensions of cholesterol crystals of atheromatous materials were measured with a polarizing microscope and compared with those of the ghost images of cholesterol crystals. RESULTS: SRAP were detected in 262 patients (80.9%); 120 of 262 patients had ruptured aortic plaques below the diaphragmatic level. Samples were successfully obtained from 96 patients. The detected numbers of atheromatous material, fibrin, macrophage, and calcification were 237 (49.1%), 244 (50.6%), 111 (23.0%), and 127 (26.3%) out of 482 samples, respectively. The median lengths and widths of the sampled plaques were 254 μm (interquartile range [IQR]: 100 to 685 μm) and 148 μm (IQR: 535 to 423.5 μm), respectively. The lengths and widths of the cholesterol crystals isolated from atheromatous materials were 40 μm (IQR: 32.7 to 53.7 μm), and 30 μm (IQR: 23 to 38 μm), respectively, compared with the respective dimensions of the ghost images of 86 μm (IQR: 53 to 119) and 13 μm (IQR: 7 to 18 μm). No embolic symptoms were observed within 24 h of general care via cardiac catheterization. CONCLUSIONS: SRAP are commonly scattered, and their dimensions were smaller than previously recognized. (Detecting Ruptured Aortic Plaques by Nonobstructive Angioscopy; UMIN000029772).

来源:J Am Coll Cardiol,查看原文。版权归原作者所有。

引用

  1. Komatsu S, Yutani C, Ohara T, et al. Angioscopic Evaluation of Spontaneously Ruptured Aortic Plaques. J Am Coll Cardiol. 2018. PMID: 29929612. doi:10.1016/j.jacc.2018.03.539

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。